GE 60-639-43-EUR-OD manual Indoor Motion Sensor Lens Replacement, Animal Alley Lens Guidelines

Page 4

Note

If the shorting jumper is not used or placed incorrectly, the sensor defaults to stan- dard sensitivity.

Indoor Motion Sensor Lens Replacement

1.To change the lens, first remove the sensor from its mounting plate by depressing the button on the top of the sensor.

2.Remove the cover by depressing the two tabs on the top and the one tab on the bottom of the sensor body and sliding the cover off (see Figure 8).

3.Remove the installed lens by gently placing pressure on the lens from the outside of the lens.

4.Replace with the appropriate lens by aligning its notches with the appropriate tabs in the cover.

5.Install the new lens with the smooth side facing out and the grooved side facing in.

6.Replace the cover and then replace the sensor in its mounting plate.

Animal Alley Lens Guidelines

The optional animal alley lens (part #60-709) provides protection in installations where pets move about freely. See Figures 2 and 4 for coverage.

Allowed mounting height is between 3 and 5 feet.

Be sure to use the flush-mount position or the corner mount position with the back of the PIR parallel to the walls. Do not use the inclined mount position since this would tilt the PIR’s field of view downward.

Position the sensor to have a clear line of sight across the protected room.

For best results, install the sensor higher than the highest point that the pet might reach in the detection area.

If the detection area contains furniture or other objects upon which the pet could climb or jump, either remove these objects, mount the PIR a safe distance above these objects, or mask these areas.

Setting the Sensitivity

The PIR is set to standard sensitivity at the factory. This sensitivity is preferred for most applica- tions and provides the best immunity to false alarms.

!High sensitivity should only be used in extremely quiet environments where thermal transients are not expected.

Caution

1.Locate the sensitivity pins by first removing the mounting plate and the sensor cover as described in steps 1 and 2 of the Lens Replacement process.

STANDARD

HIGH

Figure 7. Sensitivity Pins Locations

2.Locate the sensitivity pins under the battery on the right side of the PIR when looking at the front of the PIR.

3.To change to high sensitivity, move the shorting jumper to the pair of pins that are closer to the top of the PIR (see Figure 7).

4.Walk test the PIR to verify sensitivity.

4

Indoor/Outdoor PIR Motion Sensors Installation Instructions

Image 4
Contents Indoor Installation Guidelines InstallationProduct Summary Outdoor Installation Guidelines Mounting Use the following procedure to mount the sensor Setting the Sensitivity Indoor Motion Sensor Lens ReplacementAnimal Alley Lens Guidelines Testing Outdoor Motion SensorCoverage MaskingFinal Testing MaintenanceProgramming Replacing BatteriesDeclaration of Conformity SpecificationsMeans of Conformity Approved for use in the countries marked with a check

60-639-95R, 60-639-43-EUR, 60-639-43-EUR-OD, 60-639-95R-OD specifications

The GE 60-639-43-EUR-OD and its associated models, including the 60-639-43-EUR, 60-639-95R, and 60-639-95R-OD, represent a significant advancement in engineering solutions from General Electric, designed to meet diverse industrial needs. These models are recognized for their robust functionality and reliability in demanding operational environments.

One of the main features of these models is their versatility in application. They are engineered to cater to a variety of sectors including manufacturing, transportation, and energy. Their adaptability allows them to be seamlessly integrated into existing systems, offering enhanced performance without requiring extensive modifications.

The GE 60-639 series is fortified with advanced technologies that enhance efficiency and productivity. Key among these technologies is their use of smart monitoring systems, which provide real-time data and insights into performance metrics. This feature not only aids in predictive maintenance, minimizing downtime but also optimizes the overall workflow.

In terms of characteristics, these models are designed with a focus on energy efficiency. They utilize innovative power management technologies that reduce energy consumption while maintaining peak performance. This not only lowers operational costs but also aligns with global sustainability efforts aimed at reducing carbon footprints.

Moreover, the build quality of the GE 60-639 series is exceptional. They are constructed using high-grade materials that ensure durability and resilience against harsh operational conditions. This ruggedness translates into longer service life and lower replacement costs, making them a wise investment for businesses.

The user interface of these models is intuitive, allowing for easy operation and management. With streamlined controls and comprehensive diagnostic features, users can effectively monitor and manage system performance with minimal training.

In conclusion, the GE 60-639-43-EUR-OD, along with its counterparts, exemplifies GE’s commitment to innovation and reliability. With their versatile application, advanced technologies for efficiency, and robust construction, these models stand out as ideal solutions for modern industrial challenges. Organizations looking to enhance their operational capabilities would benefit significantly from integrating these reliable systems into their operations.