Outdoor Motion Sensor

Mounting

1.Determine the desired mounting location for the sensor leaving at least four inches of room above the wall mount plate to attach the sensor.

2.Using the screws and anchors supplied, attach the wall mount plate with the opening for the swivel mount facing downward.

3.Attach the sensor assembly to the wall mount plate by screwing the sensor assembly up into the opening in the wall mount plate.

4.To remove the sensor for testing or battery replacement, slide the front cover of the sensor upward until the sensor can be removed.

Filter Installation

A one inch by one inch piece of lens material has been included with the outdoor motion sensor. The filter reduces the sensors sensitivity to white light sources (sunlight and head lights) and infrared sources. Install the filter when experiencing unwanted sensor activations due to these sources.

1.Remove the sensor from its water resistant enclosure by sliding the front cover upward until the sensor can be removed.

2.Remove the mounting plate of the sensor by depressing the button on top of the sensor.

3.Remove the front cover of the sensor by depressing the two tabs on the top and the one tab on the bottom of the sensor body and sliding the cover off (see Figure 8)

4.Place the sensor on its back and drop the filter into the lens chamber covering the sensor’s detector.

5.Replace the cover, making sure the filter remains in the lens chamber and does not interfere with the attachment of the cover.

6.Replace the sensor’s mounting plate and install the sensor in its water resistant enclosure.

Testing

Walk Testing

Note

When the walk test mode has ended, an alarm can be transmitted only after 3 min- utes have passed since the previous alarm. This 3 minute lockout time reduces unnecessary RF transmis- sions in high traffic areas thereby extending battery life.

Walk testing should be done to determine the sensor’s actual coverage area. The edge of the cov- erage pattern is determined by the first flash of the LED. This may change slightly depending upon the sensitivity setting. Walk test the unit from both directions to determine the pattern boundaries.

1.Remove the sensor body from the mounted mounting plate, activate the tamper switch, and remount the body to activate the 60 second walk test mode.

2.Walk across the coverage pattern to determine the coverage area, indicated by LED activation. Each activation extends the walk test mode for an additional 60 seconds.

After 60 seconds without motion the walk test mode and the LED will no longer activate when motion is detected.

!Excessive use of the walk test mode may reduce battery life. Use only for initial setup and maintenance testing.

Caution

Environment Testing

 

Indoor Motion Sensors

 

Turn on all heating or air conditioning sources which would normally be active during the protec-

 

tion period. Stand away from the sensor and outside the coverage pattern and watch for alarms.

 

Outdoor Motion Sensors

 

Verify that the sensor’s coverage area does not extend into undesired areas that might cause

 

unwanted activations. These areas may include undesired human, pet, or automobile motion.

 

 

 

Coverage

After walk testing and environment testing are completed, masking labels can be applied to the

Masking

sensor’s lens to block detection of problem areas. The masking labels provided are cut to match

 

the corresponding lens segments.

Indoor/Outdoor PIR Motion Sensors Installation Instructions

5

Image 5
Contents Product Summary InstallationIndoor Installation Guidelines Mounting Outdoor Installation Guidelines Use the following procedure to mount the sensor Animal Alley Lens Guidelines Indoor Motion Sensor Lens ReplacementSetting the Sensitivity Outdoor Motion Sensor TestingCoverage MaskingMaintenance Final TestingProgramming Replacing BatteriesMeans of Conformity SpecificationsDeclaration of Conformity Approved for use in the countries marked with a check

60-639-95R, 60-639-43-EUR, 60-639-43-EUR-OD, 60-639-95R-OD specifications

The GE 60-639-43-EUR-OD and its associated models, including the 60-639-43-EUR, 60-639-95R, and 60-639-95R-OD, represent a significant advancement in engineering solutions from General Electric, designed to meet diverse industrial needs. These models are recognized for their robust functionality and reliability in demanding operational environments.

One of the main features of these models is their versatility in application. They are engineered to cater to a variety of sectors including manufacturing, transportation, and energy. Their adaptability allows them to be seamlessly integrated into existing systems, offering enhanced performance without requiring extensive modifications.

The GE 60-639 series is fortified with advanced technologies that enhance efficiency and productivity. Key among these technologies is their use of smart monitoring systems, which provide real-time data and insights into performance metrics. This feature not only aids in predictive maintenance, minimizing downtime but also optimizes the overall workflow.

In terms of characteristics, these models are designed with a focus on energy efficiency. They utilize innovative power management technologies that reduce energy consumption while maintaining peak performance. This not only lowers operational costs but also aligns with global sustainability efforts aimed at reducing carbon footprints.

Moreover, the build quality of the GE 60-639 series is exceptional. They are constructed using high-grade materials that ensure durability and resilience against harsh operational conditions. This ruggedness translates into longer service life and lower replacement costs, making them a wise investment for businesses.

The user interface of these models is intuitive, allowing for easy operation and management. With streamlined controls and comprehensive diagnostic features, users can effectively monitor and manage system performance with minimal training.

In conclusion, the GE 60-639-43-EUR-OD, along with its counterparts, exemplifies GE’s commitment to innovation and reliability. With their versatile application, advanced technologies for efficiency, and robust construction, these models stand out as ideal solutions for modern industrial challenges. Organizations looking to enhance their operational capabilities would benefit significantly from integrating these reliable systems into their operations.