Fedders dimensions Model F80A

Page 1

Installation, Operation and Maintenance

MODEL F80A

CATEGORY I NATURAL GAS AND LP GAS

MID EFFICIENCY WARM AIR FURNACE

TABLE OF CONTENTS

INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . .1 SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 CODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 FURNACE SIZING . . . . . . . . . . . . . . . . . . . . . .3 LOCATION of UNIT . . . . . . . . . . . . . . . . . . . .3 INSTALLATION POSITIONS . . . . . . . . . . . . . . .4 AIR CONDITIONING . . . . . . . . . . . . . . . . . . . .4 INSPECTION/ACCESS PANEL . . . . . . . . . . . . .4 CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . . .5 DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . .5 DUCTWORK . . . . . . . . . . . . . . . . . . . . . . . . . .6 DETERMING COMBUSTION AIR . . . . . . . . . .7 FURNACE VENTING . . . . . . . . . . . . . . . . . . . .8 GAS SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . .12 CONVERSIONS . . . . . . . . . . . . . . . . . . . . . . .13

HIGH ALTITUDE & AIRFLOW

SPECIFICATION TABLES . . . . . . . . . . . . . . . .14 ELECTRICAL SPECIFICATIONS . . . . . . . . . . .15

START UP PROCEDURES/

SEQUENCE OF OPERATION . . . . . . . . . . . . .17 AIR FLOW . . . . . . . . . . . . . . . . . . . . . . . . . . .19 ADJUSTING BLOWER SPEEDS . . . . . . . . . . .19 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . .20 TROUBLESHOOTING . . . . . . . . . . . . . . . . . .21 WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . .25

For future reference write down the model, serial number, and date of purchase. Use these numbers in any correspondence or service calls concerning your furnace.

Model

Serial Number

Date of Purchase

Keep these instructions for future reference.

Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your furnace. Keep this manual in a safe place for future reference.

USER’S INSTRUCTION GUIDE LOCATED AFTER PAGE 25 OF THIS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

23-23-0427N-006

Image 1
Contents Model F80A Safety Rules SafetyIntroduction Do not Destroy this Manual What to do if YOU Smell GASCodes General Furnace SizingOther Considerations Inspection / Access Panel Installation PositionsAIR Conditioning Clearances to Combustibles ClearancesGuide DuctworkDuctwork Steps Case Furnace Located in AN Unconfined Space Determing Combustion AIRCase Furnace Located in a Confined Space Definitions Furnace VentingDesign Considerations Inducer Blower Installation Vent InstallationVent Sizing Left Inducer Position 35-2 Vent ConnectorDedicated Venting Vent TerminationGAS Supply Existing Vent ConsiderationsGAS Piping Conversions High Altitude Specifications Canada High Altitude Specifications USAAirflow Specifications Outlet Regulator Pressure Vent Boss Electrical SpecificationsFurnace Connection LOW Voltage WiringImportant USE Copper Conductors only ThermostatTo Start the Furnace Start UP ProceduresTo Shut Down the Furnace Sequence of OperationChecking Furnace Input Temperature Rise CheckAirflow Annual Inspection / Service MaintenanceHUMIDIFIER/ Electronic AIR Cleaners Electronic AIR CleanerInduced Blower Circulating FANTroubleshooting 50V51-250 General Troubleshooting WHITE-RODGERS Integrated FAN Control Factory Setting User’s Information Manual Furnace Components General Safety RulesRegulator Vent Furnace Operation Information Air Filter Variations Sequence of Operation

F80A specifications

The Fedders F80A is a notable air conditioning unit that has gained recognition for its efficiency, performance, and convenience. Designed to cater to both residential and light commercial spaces, it combines robust features with advanced technologies to provide optimal cooling solutions.

One of the standout characteristics of the Fedders F80A is its impressive cooling capacity. With a BTU rating that makes it suitable for medium-sized rooms, this unit efficiently maintains comfortable indoor temperatures even during the hottest summer months. Users can benefit from its powerful performance without worrying about energy wastage.

Energy efficiency is a critical aspect of the Fedders F80A. It features an Energy Efficiency Ratio (EER) that meets current regulatory standards, which translates to lower energy bills and a reduced environmental footprint. The inclusion of eco-friendly refrigerants further enhances its appeal, making it a responsible choice for environmentally-conscious consumers.

The Fedders F80A is also equipped with user-friendly controls. An intuitive remote control allows for easy operation from anywhere in the room. Additionally, the unit comes with programmable settings that let users schedule their cooling preferences, ensuring comfort at all times without unnecessary energy expenditure.

Another key feature of this model is its multi-speed fan. The fan operates on various speeds, providing users with flexibility in airflow and noise levels. Whether a quiet night is desired or a powerful cooling burst is needed, the Fedders F80A caters to individual preferences effectively.

Installation and maintenance are also areas where the Fedders F80A shines. Its relatively straightforward installation process allows for quick setup, and its design makes routine maintenance a hassle-free task. Periodic cleaning of the filters ensures continued efficient operation, contributing to the unit's durability and longevity.

Overall, the Fedders F80A combines powerful cooling capabilities with energy efficiency and user-centric features. Its blend of technology and user-friendly design makes it a suitable choice for anyone looking to invest in reliable air conditioning. With its reputation for performance and efficiency, the Fedders F80A stands as a commendable option in the competitive air conditioning market.