Fedders F80A dimensions Furnace Operation Information

Page 29

FURNACE OPERATION INFORMATION

During the heating season, the operation of the furnace is fully automatic.

TO START THE FURNACE:

1.

First read these instructions and safety notices

 

thoroughly.

2.

Set the thermostat to the lowest setting.

3.

Ensure that all supply air registers and return air grilles

 

are open.

4.

Turn off the electric power to the furnace.

5.

Remove the burner access door.

6.

Ensure that the appliance manual shutoff valve is in the

 

"ON" position. The valve handle is normally in-line

 

with the gas pipe and valve body when it is in the "ON"

 

position perpendicular to the gas piping and valve

 

body when it is in the "OFF" position.

7.

Wait 5 minutes to clear out any gas. If, after this time

 

you smell gas, STOP. Turn the appliance manual shutoff

 

valve to the "OFF" position. If burning propane or

 

other LP gas, smell for gas near the floor since propane

 

and butane are both heavier than air. If after this time

WARM AIR FURNACE

FURNACE SHUTDOWN PROCEDURE

1.Set the thermostat to its lowest setting.

2.Shut off electric power to the furnace.

3.Turn the appliance manual shutoff valve to the "OFF" position.

4.Remove the burner access door, move the manual gas control switch to the "OFF" position, then reinstall the burner access door.

If you intend to be away from home for lengthy periods of time during the nonheating season, it is advisable to follow the furnace shutdown procedure.

Figure 3

Outlet

 

 

 

 

 

 

 

Regulator

Pressure

 

 

 

 

 

 

 

Vent

Boss

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

you do not smell gas, continue to the next step.

8.

Gas valve: Ensure that the Gas Valve Control is in the

 

"ON" position, see Figure 3 at right.

9.

Replace the burner access door, ensuring that it is

 

properly in place.

10.

Restore the electric power to the furnace.

11.

Adjust the thermostat to the desired setting. If the

 

thermostat also controls an air conditioning system,

Inlet Pressure Boss (Optional)

Connection

 

Gas Valve Control

Terminals

 

Regulator Adjustment

ensure that the thermostat system switch is in the

"HEAT" or "AUTO" mode.

If this is the first time that the furnace has undergone a trial ignition since installation, or if there has been work done on the gas lines, the furnace might not light because of air trapped in the gas supply line.

Simply turn the thermostat down to its lowest setting, wait 5 minutes, then adjust the thermostat to the desired setting. If the problem persists, proceed to the Furnace Shut Down Procedure and call your installer, service agency or gas supplier.

If you intend to be away from home for lengthy periods of time during the non-heating season, it is advisable to follow the furnace shut down procedure.

WARNING

NEVER USE TOOLS TO TURN A MANUAL GAS CONTROL HANDLE. IF THE CONTROL HANDLE WILL NOT TURN BY HAND, DO NOT ATTEMPT TO FORCE IT. DOING SO COULD RESULT IN FIRE OR EXPLOSION RESULTING IN SERIOUS PERSONAL INJURY OR DEATH, OR PROPERTY DAMAGE. CALL A QUALIFIED INSTALLATION CONTRACTOR, SERVICE AGENCY OR GAS SUPPLIER.

WARNING

DEVICES ATTACHED TO EITHER THE VENT OR COMBUSTION AIR INTAKE FOR THE PURPOSES OF EXCEEDING THE LIMITATIONS DESCRIBED IN THE INSTALLATION MANUAL, INCLUDING FIELD INSTALLED INDUCED BLOWER FANS HAVE NOT BEEN TESTED AND ARE NOT INCLUDED IN THE DESIGN CERTIFICATION OF THE FURNACE.

THE MANUFACTURER CANNOT AND WILL NOT SPECULATE ON THE EFFECTS OF SUCH MODIFICATIONS, AND CANNOT AND WILL NOT BE RESPONSIBLE FOR INJURY OR DAMAGE CAUSED BY THE USE OF SUCH UNTESTED AND/OR UNCERTIFIED DEVICES, ACCESSORIES OR COMPONENTS.

WARNING

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH

FOR ASSISTANCE OR ADDITIONAL INFORMATION, CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY, OR YOUR GAS SUPPLIER.

2

Image 29
Contents Model F80A Introduction SafetySafety Rules Codes What to do if YOU Smell GASDo not Destroy this Manual Other Considerations Furnace SizingGeneral AIR Conditioning Installation PositionsInspection / Access Panel Clearances to Combustibles ClearancesDuctwork Steps DuctworkGuide Case Furnace Located in a Confined Space Determing Combustion AIRCase Furnace Located in AN Unconfined Space Design Considerations Furnace VentingDefinitions Vent Sizing Vent InstallationInducer Blower Installation Left Inducer Position 35-2 Vent ConnectorDedicated Venting Vent TerminationGAS Piping Existing Vent ConsiderationsGAS Supply Conversions Airflow Specifications High Altitude Specifications USAHigh Altitude Specifications Canada Outlet Regulator Pressure Vent Boss Electrical SpecificationsFurnace Connection LOW Voltage WiringImportant USE Copper Conductors only ThermostatTo Start the Furnace Start UP ProceduresTo Shut Down the Furnace Sequence of OperationChecking Furnace Input Temperature Rise CheckAirflow Annual Inspection / Service MaintenanceHUMIDIFIER/ Electronic AIR Cleaners Electronic AIR CleanerInduced Blower Circulating FANTroubleshooting 50V51-250 General Troubleshooting WHITE-RODGERS Integrated FAN Control Factory Setting User’s Information Manual Regulator Vent General Safety RulesFurnace Components Furnace Operation Information Air Filter Variations Sequence of Operation

F80A specifications

The Fedders F80A is a notable air conditioning unit that has gained recognition for its efficiency, performance, and convenience. Designed to cater to both residential and light commercial spaces, it combines robust features with advanced technologies to provide optimal cooling solutions.

One of the standout characteristics of the Fedders F80A is its impressive cooling capacity. With a BTU rating that makes it suitable for medium-sized rooms, this unit efficiently maintains comfortable indoor temperatures even during the hottest summer months. Users can benefit from its powerful performance without worrying about energy wastage.

Energy efficiency is a critical aspect of the Fedders F80A. It features an Energy Efficiency Ratio (EER) that meets current regulatory standards, which translates to lower energy bills and a reduced environmental footprint. The inclusion of eco-friendly refrigerants further enhances its appeal, making it a responsible choice for environmentally-conscious consumers.

The Fedders F80A is also equipped with user-friendly controls. An intuitive remote control allows for easy operation from anywhere in the room. Additionally, the unit comes with programmable settings that let users schedule their cooling preferences, ensuring comfort at all times without unnecessary energy expenditure.

Another key feature of this model is its multi-speed fan. The fan operates on various speeds, providing users with flexibility in airflow and noise levels. Whether a quiet night is desired or a powerful cooling burst is needed, the Fedders F80A caters to individual preferences effectively.

Installation and maintenance are also areas where the Fedders F80A shines. Its relatively straightforward installation process allows for quick setup, and its design makes routine maintenance a hassle-free task. Periodic cleaning of the filters ensures continued efficient operation, contributing to the unit's durability and longevity.

Overall, the Fedders F80A combines powerful cooling capabilities with energy efficiency and user-centric features. Its blend of technology and user-friendly design makes it a suitable choice for anyone looking to invest in reliable air conditioning. With its reputation for performance and efficiency, the Fedders F80A stands as a commendable option in the competitive air conditioning market.