Fedders F80A dimensions User’s Information Manual

Page 27

User’s Information Manual

MODEL F80A SERIES GAS-FIRED WARM AIR FURNACE

TABLE OF CONTENTS

 

FURNACE COMPONENTS

.1

REGULATOR VENT

.1

GENERAL SAFETY RULES

.1

FURNACE OPERATION INFORMATION

 

TO START THE FURNACE

.2

FURNACE SHUTDOWN PROCEDURE . . . .

.2

MAINTENANCE

 

AIR FILTER

.3

LUBRICATION

.3

ROUTINE EXAMINATION

.3

FURNACE APPEARANCE

.4

CLEANING

.3

SEQUENCE OF OPERATION

.4

READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING TO OPERATE THIS FURNACE.

This furnace has been designed to deliver many years of efficient, dependable service. With regular maintenance, some of which requires the attention of a qualified installer, service agency or gas supplier, some of which you may do yourself, the furnace will operate satisfactorily over many heating seasons.

Please read this manual to familiarize yourself with safety procedures, operation, and routine maintenance procedures.

WARNING

WHAT TO DO IF YOU SMELL GAS:

DO NOT TRY TO LIGHT ANY APPLIANCE

DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING

LEAVE THE BUILDING IMMEDIATELY

IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A PHONE OUTSIDE THE BUILDING. FOLLOW THE GAS SUPPLIER’S INSTRUCTIONS

IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER

DO NOT USE THIS FURNACE IF ANY PART HAS BEEN UNDER WATER. A FLOOD DAMAGED FURNACE IS EXTREMELY DANGEROUS. ATTEMPTS TO USE THE FURNACE CAN RESULT IN FIRE OR EXPLOSION. A QUALIFIED SERVICE AGENCY SHOULD BE CONTACTED TO INSPECT THE FURNACE AND TO REPLACE ALL GAS CONTROLS, CONTROL SYSTEM PARTS, ELECTRICAL PARTS THAT HAVE BEEN WET OR THE FURNACE IF DEEMED NECESSARY.

FIRE OR EXPLOSION HAZARD

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

FAILURE TO FOLLOW SAFETY WARNINGS EXACTLY COULD RESULT IN SERIOUS INJURY, DEATH, OR PROPERTY DAMAGE.

Image 27
Contents Model F80A Safety Safety RulesIntroduction What to do if YOU Smell GAS Do not Destroy this ManualCodes Furnace Sizing GeneralOther Considerations Installation Positions Inspection / Access PanelAIR Conditioning Clearances to Combustibles ClearancesDuctwork GuideDuctwork Steps Determing Combustion AIR Case Furnace Located in AN Unconfined SpaceCase Furnace Located in a Confined Space Furnace Venting DefinitionsDesign Considerations Vent Installation Inducer Blower InstallationVent Sizing Left Inducer Position 35-2 Vent ConnectorDedicated Venting Vent TerminationExisting Vent Considerations GAS SupplyGAS Piping Conversions High Altitude Specifications USA High Altitude Specifications CanadaAirflow Specifications Outlet Regulator Pressure Vent Boss Electrical SpecificationsThermostat LOW Voltage WiringFurnace Connection Important USE Copper Conductors onlySequence of Operation Start UP ProceduresTo Start the Furnace To Shut Down the FurnaceChecking Furnace Input Temperature Rise CheckAirflow Annual Inspection / Service MaintenanceCirculating FAN Electronic AIR CleanerHUMIDIFIER/ Electronic AIR Cleaners Induced BlowerTroubleshooting 50V51-250 General Troubleshooting WHITE-RODGERS Integrated FAN Control Factory Setting User’s Information Manual General Safety Rules Furnace ComponentsRegulator Vent Furnace Operation Information Air Filter Variations Sequence of Operation

F80A specifications

The Fedders F80A is a notable air conditioning unit that has gained recognition for its efficiency, performance, and convenience. Designed to cater to both residential and light commercial spaces, it combines robust features with advanced technologies to provide optimal cooling solutions.

One of the standout characteristics of the Fedders F80A is its impressive cooling capacity. With a BTU rating that makes it suitable for medium-sized rooms, this unit efficiently maintains comfortable indoor temperatures even during the hottest summer months. Users can benefit from its powerful performance without worrying about energy wastage.

Energy efficiency is a critical aspect of the Fedders F80A. It features an Energy Efficiency Ratio (EER) that meets current regulatory standards, which translates to lower energy bills and a reduced environmental footprint. The inclusion of eco-friendly refrigerants further enhances its appeal, making it a responsible choice for environmentally-conscious consumers.

The Fedders F80A is also equipped with user-friendly controls. An intuitive remote control allows for easy operation from anywhere in the room. Additionally, the unit comes with programmable settings that let users schedule their cooling preferences, ensuring comfort at all times without unnecessary energy expenditure.

Another key feature of this model is its multi-speed fan. The fan operates on various speeds, providing users with flexibility in airflow and noise levels. Whether a quiet night is desired or a powerful cooling burst is needed, the Fedders F80A caters to individual preferences effectively.

Installation and maintenance are also areas where the Fedders F80A shines. Its relatively straightforward installation process allows for quick setup, and its design makes routine maintenance a hassle-free task. Periodic cleaning of the filters ensures continued efficient operation, contributing to the unit's durability and longevity.

Overall, the Fedders F80A combines powerful cooling capabilities with energy efficiency and user-centric features. Its blend of technology and user-friendly design makes it a suitable choice for anyone looking to invest in reliable air conditioning. With its reputation for performance and efficiency, the Fedders F80A stands as a commendable option in the competitive air conditioning market.