Goodman Mfg Goodman 90%-95% Gas Furnace Units, GCVC9/GMVC95 Furnace Specifications AMVC95

Page 17

FURNACE SPECIFICATIONS

 

 

 

AMVC95

MODEL

AMVC950453BX*

AMVC950704CX*

AMVC950905CX*

AMVC950905DX*

AMVC951155DX*

 

 

 

 

 

 

 

 

 

Btuh Input (US) High Fire

46,000

69,000

92,000

92,000

 

115,000

 

Output (US) High Fire

44,300

66,900

88,800

88,800

 

111,100

 

Btuh Input (US) Low Fire

32,000

48,000

64,000

64,000

 

80,000

 

Output (US) Low Fire

30,800

46,400

61,700

61,700

 

77,400

 

A.F.U.E.

99%

95.5%

95.7%

95.7%

 

95.8%

 

 

 

 

 

 

 

 

 

Rated External Static (" w.c.)

.10 - .50

.10 - .50

.10 - .50

.10 - .50

 

.10 - .50

 

Temperature Rise (°F)

30 - 60

30 - 60

30 - 60

30 - 60

 

35 - 65

 

 

 

 

 

 

 

 

 

High Stage Pressure Switch Trip Point (" w.c.)

-0.75

-0.75

-1.70

-1.10

 

-1.10

 

Low Stage Pressure Switch Trip Point (" w.c.)

-0.30

-0.30

-0.60

-0.50

 

-0.50

 

Front Cover Pressure Switch Trip Point (" w.c)

-0.10

-0.10

-0.10

-0.10

 

-0.10

 

 

 

 

 

 

 

 

 

Blower Wheel (D" x W")

10 x 8

10 x 10

11 x 10

11 x 10

 

11 x 10

 

Blower Horsepower

1/2

3/4

1

1

 

1

 

 

 

 

 

 

 

 

 

Blower Speeds

 

Refer to airflow charts in this manual.

 

 

 

Max CFM @ 0.5 E.S.P.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supply

115-60-1

115-60-1

115-60-1

115-60-1

 

115-60-1

 

Minimum Circuit Ampacity (MCA)

11.3

14.1

14.4

14.4

 

14.4

 

Maximum Overcurrent Device

15

15

15

15

 

15

 

 

 

 

 

 

 

 

 

Transformer (VA)

40

40

40

40

 

40

 

Heat Anticipator (Amps)

0.7

0.7

0.7

0.7

 

0.7

 

 

 

 

 

 

 

 

 

Primary Limit Setting (°F)

145

155

130

145

 

150

 

Auxiliary Limit Setting (°F)

150

190

120

180

 

200

 

Rollout Limit Setting (°F)

170

200

200

190

 

200

 

 

 

 

 

 

 

 

 

Fan Delay On Heating

30 secs.

30 secs.

30 secs.

30 secs.

 

30 secs.

 

Off Heating *

150 secs.

150 secs.

150 secs.

150 secs.

 

150 secs.

 

Fan Delay On Cooling

5 secs.

5 secs.

5 secs.

5 secs.

 

5 secs.

 

Off Cooling

45 secs.

45 secs.

45 secs.

45 secs.

 

45 secs.

 

Fan Delay On - Fan Only

5 secs.

5 secs.

5 secs.

5 secs.

 

5 secs.

 

 

 

 

 

 

 

 

 

Gas Supply Pressure (Natural/Propane) (" w.c.)

7 / 11

7 / 11

7 / 11

7 / 11

 

7 / 11

 

Manifold Pressure (Natural/Propane) High Stage (" w.c.)

3.5 / 10

3.5 / 10

3.5 /10

3.5 /10

 

3.5 /10

 

Manifold Pressure (Natural/Propane) Low Stage ("w.c.)

1.9 / 6.0

1.9 / 6.0

1.9 / 6.0

1.9 / 6.0

 

1.9 / 6.0

 

Orifice Size (Natural/Propane)

#43 / #55

#43 / #55

#43 / #55

#43 / #55

 

#43 / #55

 

Number of Burners

2

3

4

4

 

5

 

 

 

 

 

 

 

 

 

Vent Connector Diameter (inches)

2

2

2

2

 

2

 

Combustion Air Connector Diameter (inches)

2

2

2

2

 

2

 

 

 

 

 

 

 

 

 

Shipping Weight (lbs.)

133

157

172

172

 

184

 

 

 

 

 

 

 

 

 

* Off Heating - This fan delay timing is adjustable (90, 120, 150 or 180 seconds), 150 seconds as shipped.

1.These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation.

2.For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altitude.

3.The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufactures method in accordance with the "A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times output.

4.Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.

17

Image 17
Contents Technical Manual 070 Product IdentificationDo not connect or use any device General Operation Product DesignSingle Stage Thermostat Component Identification Cabinet Units Size Cabinet Units Size DATA2 Product Primary Limit Auxiliary Limit Switches Coil Matches 1824Filters ThermostatsCounterflow Filters Model GMVC95Furnace Specifications AMVC95 GCVC90704CX GCVC90905DX GCVC91155DX Furnace Specifications GCVC9D E L Furnace Specifications GCVC95Furnace Specifications ACVC9 Furnace Specifications ACVC95 GMVC95/AMVC95 Heating Speed Charts Blower Performance SpecificationsESP GMVC95/AMVC95 High Single Stage Cooling Speed Charts GMVC95/AMVC95 Low Stage Cooling Speed Charts GCVC95/ACVC95 Continuous Fan Speed Chart GMVC95/AMVC95 Continuous Fan Speed ChartGCVC9/ACVC9 Continuous Fan Speed Chart GCVC9/ACVC9 Heating Speed Charts ESP GCVC95/ACVC95 Heating Speed ChartsGCVC9/ACVC9 Low Stage Cooling Speed Charts GCVC9/ACVC9 High Single Stage Cooling Speed ChartsGCVC95/ACVC95 Low Stage Cooling Speed Charts GCVC95/ACVC95 High Single Stage Cooling Speed ChartsDehumidification Enable Switch Circulator Blower Speed Adjustment SwitchesRamping Profile Performance 24V HUM Wiring Diagrams CVC9/*MVC95AA24VHUM Wiring Diagrams CVC9/*MVC95ABTerminal SchematicsSchematicwiring

Goodman 90%-95% Gas Furnace Units, ACVC9/AMVC95, GCVC9/GMVC95 specifications

Goodman Manufacturing is a prominent name in the HVAC industry, known for providing energy-efficient solutions that cater to both residential and commercial environments. Among its offerings, the Goodman GCVC9/GMVC95 and ACVC9/AMVC95 models stand out as top-tier gas furnace units, with efficiency ratings between 90% and 95%. These furnaces provide an excellent balance of performance, reliability, and affordability.

The GCVC9 and GMVC95 gas furnace units are designed with advanced features that ensure optimal heating and comfort. One of the key characteristics of these models is their energy efficiency. With Annual Fuel Utilization Efficiency (AFUE) ratings of up to 95%, these furnaces convert nearly all the fuel they consume into heat, resulting in significant cost savings on energy bills. This makes them an ideal choice for homeowners looking to reduce their carbon footprint while maintaining a comfortable indoor environment.

These units are equipped with a two-stage gas valve and a variable-speed blower motor. The two-stage gas valve allows for precise temperature control by providing two levels of heating output, ensuring that the furnace runs at lower capacities during milder conditions and ramping up when more heat is needed. The variable-speed blower motor enhances comfort by providing consistent airflow, reducing temperature fluctuations, and operating more quietly than single-speed motors.

Another notable feature is the firing system, which utilizes a hot surface igniter for reliable operation. This technology enhances safety and performance, eliminating the need for a pilot light and minimizing gas waste. Additionally, both models are designed for easy installation and maintenance, with features like a compact design and convenient access to internal components.

Durability is also a hallmark of Goodman furnaces. The units are constructed with high-quality materials, including a heavy-gauge steel cabinet and a durable powder-coated finish to resist corrosion. Furthermore, Goodman offers exceptional warranties, including a lifetime heat exchanger warranty, providing peace of mind for homeowners.

In conclusion, the Goodman GCVC9/GMVC95 and ACVC9/AMVC95 gas furnace units are engineered for efficient heating with advanced technologies that enhance performance and comfort. Their high AFUE ratings, reliable ignition system, and durable construction make them excellent choices for anyone looking to invest in a reliable heating solution. With Goodman at the helm, homeowners can enjoy efficient heating without compromising on comfort or cost.