Langley/Empire DV-40E-5, DV-20E-5 Lighting Instructions, For Your Safety Read Before Operating

Page 13

LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result caus-

ing property damage, personal injury or loss of life.

A.This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance.

4.This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.

VINYL CAP

GAS CONTROL LEVER SHOWN

 

IN "OFF" POSITION

CONVERTIBLE

REGULATOR

OFF

TOP VIEW

BACK END VIEW

5.Remove control access panel (front panel).

6.Turn gas control knob clockwise to "OFF."

7.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

8. Tu r n g a s c o n t r o l k n o b c o u n t e r c l o c k w i s e to "ON".

9.Replace control access panel (front panel).

10.Turn on all electric power to the appliance.

11.Set thermostat to desired setting.

12.If the appliance will not operate, follow the instructions "TO TURN OFF GAS TO APPLIANCE" and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the appliance if service is to be performed .

3.Remove control access panel (front panel).

4.Turn gas control knob clockwise to "OFF." Do not force.

5.Replace control access panel (front panel).

19562-1-0606

Page 13

Image 13
Contents What to do if YOU Smell GAS Installation InstructionsTable of Contents Do not Operate this Appliance Without Front Panel Installed Important Safety InformationLP-GAS Warning Odor Safety Informtion for Users of LP-GASNo Odor Detected Odor Fade Clear of ALL Obstructions Requirements for MassachusettsIntroduction SpecificationsGAS Supply Pressure Testing of the Gas Supply SystemRecommended Gas Pipe Diameter Checking Manifold PressureConversion Instructions from LP Propane GAS to Natural GAS GAS Conversion InstructionsConversion Instructions from Natural GAS to LP Propane GAS Installation on Rugs and Tile Furnace InstallationClearances Locating Wall Opening Figures 2, 3Venting Figures 7, 8 Installing Wall Bracket Figures 5Vent Terminal Figure Furnace InstallationCondensate Removal Figures 11 Reassembly and Resealing Vent-Air Intake SystemLighting Instructions For Your Safety Read Before OperatingReplacement of Thermistor with 24 Volt Wall Thermostat WiringInternal Electronic Thermostat/Temperature Control Board Operation and Troubleshooting Maintenance# of Blinks Fault Condition Fault Correction Furnace Control Board DiagnosticsParts List HOW to Order Repair PartsParts View Service Notes