FURNACE CONTROL BOARD
DIAGNOSTICS
FAULT SEQUENCE CODE — TROUBLE SHOOTING GUIDE
# of Blinks | Fault Condition | Fault Correction | |
Steady On | Control OK |
| |
1 | Flash | Temperature limit switch is open | |
|
|
| Blower/Circulating Air Blower Run to Cool Heat Exchanger and Limit |
|
|
| |
|
|
| Burner Box to Open |
|
|
| |
2 | Flashes | Pressure switch is open with inducer on | |
|
|
| |
|
|
| |
3 | Flashes | Pressure switch is closed with inducer off | |
4 | Flashes | Lockout due to failed ignition | |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
5 | flashes | L1/Neutral reversed or voltage not present | |
|
| on L1 | tacle. |
|
|
| Open Junction Box and |
Rapid Flash | Flame sense or internal control fault | ||
|
|
| |
|
|
| |
|
|
|
Note: If the hot surface ignitor is to be replaced, be sure to disconnect all power to the unit. Be very careful in handling the new ignitor as they are fragile and can be broken easily if hit or dropped.
Page 16 |