Johnson Controls CM8M/CMLM*MP Bottom Return and Attic Installations, Horizontal Application

Page 7

368261-UIM-A-0508

BOTTOM RETURN AND ATTIC INSTALLATIONS

Bottom return applications normally pull return air through a base plat- form or return air plenum. Be sure the return platform structure or return air plenum is suitable to support the weight of the furnace.

The internal bottom panel must be removed for this application.

Attic installations must meet all minimum clearances to combustibles and have floor support with required service accessibility.

HORIZONTAL APPLICATION

FIGURE 9: Horizontal Application

This furnace may be installed in a horizontal position on either side as shown above. It must not be installed on its back.

ATTIC INSTALLATION

When a furnace is installed in an attic or other insulated space, keep all insulating materials at least 12 inches (30.5 cm) away from furnace and burner combustion air openings.

SUSPENDED FURNACE / CRAWL SPACE INSTALLATION

The furnace can be hung from floor joists or installed on suitable blocks or pad. Blocks or pad installations shall provide adequate height to ensure the unit will not be subject to water damage. Units may also be suspended from rafters or floor joists using rods, pipe angle supports or straps. Angle supports should be placed at the supply air end and near the blower deck. Do not support at return air end of unit. All four sus- pension points must be level to ensure quite furnace operation. When suspending the furnace use a secure platform constructed of plywood or other building material secured to the floor joists. Refer to for typical crawl space installation.

Support

Angle IronBracket

Bracket

Line contact only permissible between lines formed by the intersection of furnace top and two sides and building joists, studs or framing

Filter rack

 

must be a minimum

 

distance

Gas Piping

of 18” (45.7 cm)

 

from the

 

furnace

 

Supply

Air

Vent (Maintain required clearances to combustibles)

Sheet metal in

front of furnace

combustion air

12”Openings is Recommended

12

30” MIN. Work Area

6” Min. Between

Rod & Front of Furnace1” Max. Between

Rod & Back of Furnace

FIGURE 11: Typical Suspended Furnace / Crawl Space Installation

DOWNFLOW APPLICATION

To apply the furnace in a downflow position, it will be necessary to rotate the vent blower 90° left or right so that the vent pipe passes

Return

AirSediment

Trap

FIGURE 10: Typical Attic Installation

This appliance is certified for line contact when the furnace is installed in the horizontal left or right position. The line contact is only permissible between lines that are formed by the intersection of the top and two sides of the furnace and the building joists, studs or framing. This line may be in contact with combustible material. Refer to Figure 10, "Typi- cal Attic Installation".

through the side of the furnace casing rather than the end. See Figure 12, "Downflow Venting".

For modulating furnaces to be used in the downflow position, it is necessary to rotate the gas valve so that it is upright when the fur- nace is installed. Loosen the pipe union between the gas valve and manifold, rotate the valve as far upward as it will go, and tighten the union. See Figure 13, "Downflow Installation - Gas Valve Rotation".

Rotate vent blower 90° either way

For downflow installation,rotate

gas valve upwards, as shown

LEFT SIDE VENT

RIGHT SIDE VENT

FIGURE 12: Downflow Venting

FIGURE 13: Downflow Installation - Gas Valve Rotation

Johnson Controls Unitary Products

7

Image 7
Contents List of Figures Section I SafetyModels List of SectionsCombustion AIR Quality List of Contaminants Specific Safety Rules and PrecautionsSafety Requirements Ance to a 50 HZ Power Supply or a Voltage Above 130 VoltsInspection Codes and StandardsFurnace Location and Clearances Section II DuctworkDuctwork General Information Coil Flange Installation Floor Base and Ductwork Installation DownflowCOIL/FURNACE Assembly MC/FC/PC Series Coils Furnace Assembly MC & FC Series CoilsCritical Coil Projection Furnace Assembly PC Series CoilsCoil / Furnace Assembly HC Series Coils Downflow Duct ConnectorsHorizontal Application Bottom Return and Attic InstallationsAttic Installation Suspended Furnace / Crawl Space InstallationSide Return Filter InstallationAttempt to install filters inside the furnace Section III FiltersGAS Conversion for Propane LP GAS SafetyGAS Piping Installation Section IV GAS PipingElectrical Power Connections Section V Electrical PowerHigh Altitude Natural GAS Orifice Conversion Zoning Operation LOW Voltage Control Wiring ConnectionsSupply Voltage Connections AIR Conditioner ConnectionsID Models ThermostatModulating TWO Stage AIR Furnace Conditioner UIM-A-0508 Single Stage Heat Pump Modulating Furnace OD ModelsThermostat TWO Stage Heat Pump Modulating FurnaceSection VII Vent System Section VI Twinning and StagingFree Area Combustion Air Source From OutdoorsDampers, Louvers and Grilles Canada Only Air Supply Openings and DuctsNOx Screen Removal Lo-NOx Models Only Section Viii START-UP AdjustmentsVent and Supply Outside Air Safety Check Procedure Ventilated Combustion AirGAS Piping Leak Check Setup Test ModeCalculating the Furnace Input Natural GAS Revolution Cu Ft Seconds ForAdjustment of Temperature Rise Adjustment of Manifold GAS PressureRollout Switch Controls Section IX Safety ControlsAdjustment of FAN Control Settings Blower Door Safety SwitchLimit Controls Section X Normal Operation and DiagnosticsFurnace Control Diagnostics Pressure ControlsDiagnostic Fault Code Storage and Retrieval Fabricated Parts Section XI Replacement Parts ListJohnson Controls Unitary Products York Drive Norman, OK Section XII Wiring Diagram

LM8M/LMLM*MP, TM8M/TMLM*MP, CM8M/CMLM*MP, YM8M/YMLM*MP specifications

Johnson Controls TM8M/TMLM*MP, YM8M/YMLM*MP, LM8M/LMLM*MP, and CM8M/CMLM*MP are advanced temperature controllers designed for a wide range of applications in heating, ventilation, and air conditioning (HVAC) systems. These models stand out due to their robust features, cutting-edge technologies, and specific characteristics that cater to both residential and commercial environments.

One of the main features of the TM8M/TMLM*MP series is its user-friendly interface that incorporates a large, easy-to-read display. This allows for quick adjustments and monitoring of temperature settings, making it accessible for both skilled technicians and everyday users. The intuitive design ensures that users can efficiently navigate through various settings and configurations.

Another notable characteristic is the flexibility of these controllers. The series supports multiple sensor configurations, enabling the integration of both wired and wireless sensors. This adaptability allows users to customize their climate control systems according to specific needs and room layouts, ultimately enhancing comfort and energy efficiency.

The TM8M/TMLM*MP and its counterparts are equipped with sophisticated algorithms that optimize energy consumption. By utilizing predictive maintenance and intelligent analytics, these controllers can adjust settings dynamically based on real-time data. This not only helps in reducing operational costs but also prolongs the lifespan of HVAC equipment.

Incorporating advanced communication protocols is a hallmark of the Johnson Controls series. The TM8M and CM8M models support modern systems such as BACnet and Modbus, allowing seamless integration with building management systems (BMS). This compatibility ensures that users can maintain centralized control over multiple systems, enhancing overall operational efficiency.

Additionally, the series is robustly constructed to withstand harsh environmental conditions. Its durable casing and reliable components ensure long-term performance, making it suitable for a variety of settings, including industrial facilities and commercial properties.

Safety features are also integral to the design of the TM8M/TMLM*MP and related models. Built-in safeguards protect against over-temperature and other potential hazards, ensuring reliability and peace of mind for operators.

In summary, Johnson Controls TM8M/TMLM*MP, YM8M/YMLM*MP, LM8M/LMLM*MP, and CM8M/CMLM*MP controllers represent a convergence of user-friendly design, advanced technology, flexibility, and safety. Their ability to adapt to diverse applications while optimizing energy use makes them a critical component in modern HVAC systems, ensuring comfort and efficiency in every environment.