Louisville Tin and Stove DVCF558B-R, DVCF654B-R, DVCF404B-R, DVCF653B-R, DVCF557B-R Safety Rules

Page 3

SAFETY RULES

1.Follow all applicable local codes and ordinances. If there are none, follow the latest edition of the National Fuel Gas Code, ANSI.Z223.1. A copy may be obtained from American Gas Association, 1515 Wilson Blvd., Arlington, Virginia 22209, or the National Fire Protection Association, Batterymarch Park, Quincy, MA. 02269. In Canada, see the current CAN1-B149 installation code, available from International Approval Services, 55 Scarsdale Road, Don Mills, Ontario, Canada M3B-2R3.

2.The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the latest edition of National Electrical Code, ANSI/NFPA70. In Canada, see the current CSA C22.2 Canadian Electrical Code, available from International Approval Services, 178 Rexdale Boulevard, Etobicoke, Ontario, Canada M9W 1R3.

3.Do not install this furnace in a recreational vehicle or trailer.

4.Do not operate this furnace unless it is connected to the supplied vent system with vent cap in place. Do not attempt to extend vent pipes. 12 inches is maximum length.

5.Never use a match, candle, flame or other source of ignition to check for gas leaks. Use only soapy water or liquid detergent.

6.Before cleaning or servicing, turn off the gas and allow furnace to cool.

7.Do not operate furnace without grilles and front panel in place.

8.Due to high temperatures, locate furnace out of traffic and away from furniture and drapes.

9.Children and adults should be alerted to the hazard of high surface temperature and should be kept away to avoid burns or clothing ignition.

10.Young children should be carefully supervised when they are in the same room with the furnace.

11.Do not place clothing or other flammable material on or near the furnace.

12.Installation and repair should be done by a qualified service person. The furnace should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, and circulating air passageways of the furnace be kept clean.

13.Do not put anything around the furnace or vent cap that will obstruct the flow of combustion and ventilation air.

14.When installing the furnace allow adequate accessibility clearances for servicing and proper operation. (See Figure 1 – Page 5).

15.When the furnace is installed directly on carpeting, tile or other combustible material other than wood flooring, the furnace shall be installed on a metal or wood panel extending the full width and depth of the furnace.

16.Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system which has been under water.

17.For your safety, this furnace is equipped with a manual reset auxiliary limit switch. In case of failure by the primary limit switch, this switch will shut the valve down completely before unsafe temperatures are reached. After a cool down period, switch must be manually reset. If outages persist, call a qualified service person.

18.Side discharge kit boots must not exceed 10 inches.

19.Locate the auxiliary limit switch and push in the red reset button. This will reset the switch in case it accidentally opened during shipping.

Page 3

Image 3
Contents NAT. GAS DVCF403B-R DVCF653B-R DVCF404B-R DVCF654B-R NAT. GAS DVCF407B-R DVCF557B-R DVCF408B-R DVCF558B-RWhat to do if YOU Smell GAS Introduction ContentsSafety Rules Vent Terminal Clearances Floor ClearancesDIA Wall Installation Electrical ROUGH-INLocations ROUGH-IN GAS SupplyGAS Connection Installing the FurnaceThermostat Installation Locate Vent OpeningTo Turn OFF GAS to Appliance Lighting InstructionsA fire or explosion Pilot Adjustment To Remove Main Burner forProper Burner Flame DVCF403B, DVCF404B Standing Pilot Pictorial SchematicDVCF403 DVCF404 Ladder Schematic DVCF653 DVCF654 Ladder SchematicMotor DVCF407 DVCF408 Ladder SchematicDVCF557 DVCF558 Ladder Schematic DVCF407B, DVCF408BTerminal Block Wiring Diagram Manual Reset SwitchMaintenance Instruction ROUGH-INS for Side Discharge Side KIT no SRB Side Register W/BOOTOptional Side Discharge Kits Side Discharge on Casing KIT no SR Side Register Flush14’ Plug Extension KIT For NON-RECESSED Installations only PEK KIT InstructionsUnits with Terminal Board Step # Symptom Possible Causes Corrective Action Trouble Shooting ChartSymptom Possible Causes Corrective Action Service RecordDVCF40B-R, DVCF55B-R, DVCF65B-R Series Spark Igniter Thermostat Burner AssemblyDirect Vent Counterflow Wall Furnace Vent AssemlbyPart List Part Description Price HOW to Properly Order PartsPart Description Critical Safety Points to Remember Your GAS Control and Pilot Light SystemTampering is Dangerous Table a Louisville TIN and Stove Company

DVCF557B-R, DVCF653B-R, DVCF654B-R, DVCF403B-R, DVCF408B-R specifications

The Louisville Tin and Stove DVCF series offers a range of innovative and versatile vented gas fireplaces, designed to enhance the aesthetic appeal and comfort of any space. Key models in this series include the DVCF404B-R, DVCF654B-R, DVCF653B-R, DVCF557B-R, and DVCF407B-R. Each fireplace is engineered with advanced features and technologies, ensuring an efficient and enjoyable heating experience.

The DVCF404B-R is a compact yet powerful model, perfect for smaller areas. It delivers a heat output of up to 30,000 BTUs, providing ample warmth while maintaining energy efficiency. Its sleek design and modern appearance make it an attractive focal point in any room. The DVCF654B-R, on the other hand, boasts a larger heating capacity, ideal for more spacious environments. With BTUs reaching 38,000, this fireplace ensures that larger areas remain comfortably warm even during harsh winter months.

The DVCF653B-R combines functionality with elegance, featuring a contemporary linear design that fits well into various interior styles. Its advanced venting technology ensures easy installation and optimal performance, allowing homeowners to enjoy the flames' beauty without compromising on safety or efficiency. Meanwhile, the DVCF557B-R is particularly noteworthy for its customizable options, which enable users to choose from various finishes and decorative media, personalizing their fireplace to match their unique tastes.

Lastly, the DVCF407B-R offers a blend of traditional and modern aesthetics, making it a versatile choice for different decor styles. Its efficient heating capabilities and advanced safety features, such as automatic shut-off and a glass front for reduced emissions, make it a reliable option for families.

Overall, the Louisville Tin and Stove DVCF series not only enhances home decor but also prioritizes efficiency, safety, and ease of use. Each model embodies quality craftsmanship and modern technological advancements, making them exceptional choices for anyone looking to invest in a gas fireplace. The comprehensive features, from customizable designs to high BTU outputs, make the DVCF series a standout in the market for homeowners seeking comfort and style.