Bryant 353AAV manual Ft M, IN. mm, 2001 to, 610 to

Page 13

COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT/2-PIPE (ALL SIZES) AND NON-DIRECT VENT/1-PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS

 

 

 

 

NON-DIRECT

 

 

 

 

 

 

ALTITUDE

UNIT SIZE

DIRECT VENT (2-PIPE) ONLY

VENT (1-PIPE)

 

NUMBER OF 90° ELBOWS

 

 

 

ONLY

 

 

 

 

 

 

FT (M)

(BTUH)

 

 

 

 

 

 

 

 

 

TERMINATION

PIPE DIA

PIPE DIA

1

2

3

4

5

6

 

 

 

 

TYPE

IN. (mm)*

IN. (mm)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 (25)

1 (25)

5

NA

NA

NA

NA

NA

 

 

 

(1.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40,000

2 Pipe or 2-in

1-1/2 (38)

1-1/2 (38)

70

70

65

60

60

55

 

Concentric

(21.3)

(21.3)

(19.8)

(18.3)

(18.3)

(16.8)

 

 

 

 

 

 

 

2 (51)

2 (51)

70

70

70

70

70

70

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2 (38)

1-1/2 (38)

20

15

10

5

NA

NA

 

 

2 Pipe or 2-in

(6.1)

(4.6)

(3.0)

(1.5)

 

60,000

 

 

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

70

70

70

70

70

70

 

 

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2 (38)

1-1/2 (38)

10

NA

NA

NA

NA

NA

 

 

 

(3.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

80,000

2 Pipe or 2-in

2 (51)

2 (51)

55

50

35

30

30

20

0 to 2000

Concentric

(16.8)

(15.2)

(10.7)

(9.1)

(9.1)

(6.1)

 

 

 

(0 to 610)

 

 

2-1/2 (64)

2-1/2 (64)

70

70

70

70

70

70

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

5

NA

NA

NA

NA

NA

 

 

 

(1.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100,000

2 Pipe or 3-in

2-1/2 (64)

2-1/2 (64)

40

30

20

20

10

NA

 

Concentric

(12.2)

(9.1)

(6.1)

(6.1)

(3.0)

 

 

 

 

 

 

 

 

3 (76)

3 (76)

70

70

70

70

70

70

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-1/2 (64)

2-1/2 (64)

10

NA

NA

NA

NA

NA

 

 

 

one disk

(3.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120,000

2 Pipe or 3-in.

3 (76)†

NA

45

40

35

30

25

20

 

Concentric

(13.7)

(12.2)

(10.7)

(9.1)

(7.6)

(6.1)

 

 

 

 

 

 

 

3 (76) † no disk

3 (76)†

70

70

70

70

70

70

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIRECT VENT (2-PIPE) ONLY

NON-DIRECT

 

NUMBER OF 90° ELBOWS

 

ALTITUDE

UNIT SIZE

VENT (1-PIPE)

 

 

 

 

ONLY

 

 

 

 

 

 

FT (M)

(BTUH)

 

 

 

 

 

 

 

 

 

TERMINATION

PIPE DIA

PIPE DIA

1

2

3

4

5

6

 

 

 

 

TYPE

IN. (mm)*

IN. (mm)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2 (38)

1-1/2 (38)

67

62

57

52

52

47

 

 

2 Pipe or 2-in

(20.4)

(18.9)

(17.4)

(15.8)

(15.8)

(14.3)

 

40,000

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

70

70

70

70

70

70

 

 

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2 (38)

1-1/2 (38)

17

12

7

NA

NA

NA

 

 

2 Pipe or 2-in

(5.2)

(3.7)

(2.1)

 

60,000

 

 

 

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

70

67

66

61

61

61

 

 

 

 

 

(21.3)

(20.4)

(20.1)

(18.6)

(18.6)

(18.6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

49

44

30

25

25

15

 

 

2 Pipe or 2-in

(14.9)

(13.4)

(9.1)

(7.6)

(7.6)

(4.6)

 

80,000

 

 

 

Concentric

2-1/2 (64)

2-1/2 (64)

70

70

70

70

70

70

 

 

2001 to 3000

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

(610 to 914)

 

 

 

 

 

 

 

 

 

 

 

 

2-1/2 (64)

2-1/2 (64)

35

26

16

16

6

NA

 

 

2 Pipe or 3-in

(10.7)

(7.9)

(4.9)

(4.9)

(1.8)

 

100,000

 

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

3 (76)

3 (76)

70

70

70

70

66

61

 

 

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(20.1)

(18.6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 (76)

NA

14

9

NA

NA

NA

NA

 

 

 

(4.3)

(2.7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NA

3 (76)†

63

62

62

61

61

61

 

 

2 Pipe or 3-in.

(19.2)

(18.9)

(18.9)

(18.6)

(18.6)

(18.6)

 

120,000

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

3 (76)† no disk

NA

70

70

63

56

50

43

 

 

 

 

 

(21.3)

(21.3)

(19.2)

(17.1)

(15.2)

(13.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 (102)† no

4 (102)† no disk

70

70

70

70

70

70

 

 

 

disk

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See notes at end of table.

353AAV

13

Image 13
Contents Plus 90X Features & Benefits Unique Seer SolutionWAY Multipoise Design Allows More Applications 353AAV A08421 Physical Data Bryant Accessories Concentric Vent Direct Vent Pipe only Unitsize Ment Downflow Subbase Dimensions IN. MMMedia Filter Cabinet Condensate Trap335122-201 REV. B LIT TOP Clearance to CombustiblesEfficiency Unit Size Performance DataSize Supply AIR DELIVERY-CFM with FilterIN. mm FT M2001 to 610 to4001 to 5000‡ 1219 to 3001 to 914 to6001 to 7000‡ 5001 to 6000‡ 1524 to1829 to 8001 to 9000‡ 2438 to 7001 to 8000‡ 2134 to2743 to 9001 to 10,000‡102 040 060 080 100 120Electrical Data Typical Wiring SchematicUpflow Application Typical InstallationsCrawlspace -- Horizontal Application Products Guide SpecificationsCatalog No. PDS353AAV---03

353AAV specifications

The Bryant 353AAV is a high-efficiency, two-stage gas furnace designed to provide consistent heating and energy savings for residential spaces. With its advanced technology and robust features, the 353AAV is an ideal choice for homeowners looking to enhance their comfort while minimizing energy costs.

One of the main features of the Bryant 353AAV is its two-stage heating capability. This technology allows the furnace to operate at a lower, more efficient capacity most of the time, which not only enhances comfort by reducing temperature fluctuations but also decreases energy consumption. During peak demand, the unit can ramp up to a higher output, ensuring quick warmth when necessary.

Equipped with a variable-speed blower motor, the Bryant 353AAV improves airflow and overall system efficiency. This motor adjusts the speed based on the heating needs of the home, providing steady, even distribution of warm air. This feature reduces noise levels typically associated with traditional furnaces and enhances overall comfort by minimizing hot and cold spots.

The 353AAV also boasts an impressive Annual Fuel Utilization Efficiency (AFUE) rating, often exceeding 90%. This high AFUE indicates that a significant portion of fuel is converted into usable heat, making it an environmentally-friendly option that also saves homeowners money on utility bills. Additionally, this model is compatible with smart thermostat technology, allowing for easy and efficient climate control through mobile devices.

Durability and reliability are also key characteristics of the Bryant 353AAV. The furnace is constructed with high-quality materials, including a corrosion-resistant heat exchanger and a sturdy cabinet designed to withstand the test of time. Bryant backs the 353AAV with a 10-year limited warranty on parts, providing peace of mind for homeowners.

Finally, the Bryant 353AAV is designed with quiet operation in mind. Features like the insulated cabinet and noise-reducing blower motor contribute to a quieter home environment, making this model ideal for families and those sensitive to noise.

In summary, the Bryant 353AAV combines energy efficiency, advanced technology, and robust construction to offer homeowners a reliable heating solution. With its two-stage heating, variable-speed blower motor, high AFUE rating, and quiet operation, this gas furnace stands out as a top choice in residential heating systems.