Bryant 353AAV manual 5001 to 6000‡ 1524 to, 6001 to 7000‡, 1829 to

Page 15

COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT/2-PIPE (ALL SIZES) AND NON-DIRECT VENT/1-PIPE (SIZES 040 THROUGH 120 ONLY) APPLICATIONS (CON’T.)

 

 

DIRECT VENT (2-PIPE) ONLY

NON-DIRECT

 

NUMBER OF 90° ELBOWS

 

ALTITUDE

UNIT SIZE

VENT (1-PIPE)

 

 

 

 

ONLY

 

 

 

 

 

 

FT (M)

(BTUH)

 

 

 

 

 

 

 

 

 

TERMINATION

PIPE DIA

PIPE DIA

1

2

3

4

5

6

 

 

 

 

TYPE

IN. (mm)*

IN. (mm)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2 (38)

1-1/2 (38)

57

52

47

42

40

35

 

 

2 Pipe or 2-in

(17.4)

(15.8)

(14.3)

(12.8)

(12.2)

(10.7)

 

40,000

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

70

70

70

70

70

70

 

 

 

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2 (38)

1-1/2 (38)

14

9

NA

NA

NA

NA

 

 

2 Pipe or 2-in

(4.3)

(2.7)

 

60,000

 

 

 

 

 

 

 

Concentric

2 (51)

2 (51)

60

55

54

49

48

47

 

 

 

 

 

(18.3)

(16.8)

(16.5)

(14.9)

(14.6)

(14.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

41

36

23

18

17

8

 

 

2 Pipe or 2-in

(12.5)

(11.0)

(7.0)

(5.5)

(5.2)

(2.4)

 

80,000

 

 

 

Concentric

 

 

 

 

 

 

 

 

5001 to 6000‡

2-1/2 (64)

2-1/2 (64)

70

70

70

70

70

70

 

(1524 to 1829)

 

 

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

2-1/2 (64)

2-1/2 (64)

29

21

12

11

NA

NA

 

 

2 Pipe or 3-in

(8.8)

(6.4)

(3.7)

(3.4)

 

100,000

 

 

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

3 (76)

3 (76)

70

67

62

57

52

47

 

 

 

 

 

(21.3)

(20.4)

(18.9)

(17.4)

(15.8)

(14.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 (76)†

NA

42

35

29

22

15

9

 

 

 

no disk

(12.8)

(10.7)

(8.8)

(6.7)

(4.6)

(2.7)

 

 

 

 

 

120,000

2 Pipe or 3-in.

NA

3 (76)†

53

52

50

49

48

47

 

Concentric

(16.2)

(15.8)

(15.2)

(14.9)

(14.6)

(14.3)

 

 

 

 

 

 

 

4 (102)† no

4 (102)† no disk

70

70

70

70

70

70

 

 

 

disk

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

(21.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIRECT VENT (2-PIPE) ONLY

NON-DIRECT

 

NUMBER OF 90° ELBOWS

 

ALTITUDE

UNIT SIZE

VENT (1-PIPE)

 

 

 

 

ONLY

 

 

 

 

 

 

FT (M)

(BTUH)

 

 

 

 

 

 

 

 

 

TERMINATION

PIPE DIA

PIPE DIA

1

2

3

4

5

6

 

 

 

 

TYPE

IN. (mm)*

IN. (mm)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2 (38)

1-1/2 (38)

53

48

43

38

37

32

 

 

2 Pipe or 2-in

(16.2)

(14.6)

(13.1

(11.6)

(11.3)

(9.8)

 

40,000

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

70

70

68

67

66

64

 

 

 

 

 

(21.3)

(21.3)

(20.7)

(20.4)

(20.1)

(19.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2 (38)

1-1/2 (38)

13

8

NA

NA

NA

NA

 

 

2 Pipe or 2-in

(4.0)

(2.4)

 

60,000

 

 

 

 

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

57

52

50

45

44

43

 

 

 

 

 

(17.4)

(15.8)

(15.2)

(13.7)

(13.4)

(13.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 (51)

2 (51)

38

33

21

16

15

6

6001 to 7000‡

 

2 Pipe or 2-in

(11.6)

(10.1)

(6.4)

(4.9)

(4.6)

(1.8)

80,000

 

 

(1829 to 2134)

Concentric

 

 

 

 

 

 

 

 

2-1/2 (64)

2-1/2 (64)

70

70

68

67

66

64

 

 

 

 

(21.3)

(21.3)

(20.7)

(20.4)

(20.1)

(19.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-1/2 (64)

2-1/2 (64)

27

19

10

9

NA

NA

 

 

2 Pipe or 3-in

(8.2)

(5.8)

(3.0)

(2.7)

 

100,000

 

 

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

3 (76)

3 (76)

68

63

58

53

48

43

 

 

 

 

 

(20.7)

(19.2)

(17.7)

(16.2)

(14.6)

(13.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 (76)†

NA

31

24

18

11

NA

NA

 

 

2 Pipe or 3-in.

no disk

(9.4)

(7.3)

(5.5)

(3.4)

 

120,000

 

 

 

 

Concentric

 

 

 

 

 

 

 

 

 

NA

3 (76)†

49

48

47

45

44

43

 

 

 

 

 

(14.9)

(14.6)

(14.3)

(13.7)

(13.4)

(13.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See notes at end of table.

353AAV

15

Image 15
Contents Unique Seer Solution Plus 90X Features & BenefitsWAY Multipoise Design Allows More Applications 353AAV A08421 Physical Data Bryant Accessories Concentric Vent Direct Vent Pipe only Unitsize Ment Downflow Subbase Dimensions IN. MMMedia Filter Cabinet Condensate Trap335122-201 REV. B LIT TOP Clearance to CombustiblesEfficiency Unit Size Performance DataSize Supply AIR DELIVERY-CFM with Filter610 to FT MIN. mm 2001 to4001 to 5000‡ 1219 to 3001 to 914 to5001 to 6000‡ 1524 to 6001 to 7000‡1829 to 8001 to 9000‡ 2438 to 7001 to 8000‡ 2134 to2743 to 9001 to 10,000‡102 040 060 080 100 120Electrical Data Typical Wiring SchematicUpflow Application Typical InstallationsCrawlspace -- Horizontal Application Guide Specifications ProductsCatalog No. PDS353AAV---03

353AAV specifications

The Bryant 353AAV is a high-efficiency, two-stage gas furnace designed to provide consistent heating and energy savings for residential spaces. With its advanced technology and robust features, the 353AAV is an ideal choice for homeowners looking to enhance their comfort while minimizing energy costs.

One of the main features of the Bryant 353AAV is its two-stage heating capability. This technology allows the furnace to operate at a lower, more efficient capacity most of the time, which not only enhances comfort by reducing temperature fluctuations but also decreases energy consumption. During peak demand, the unit can ramp up to a higher output, ensuring quick warmth when necessary.

Equipped with a variable-speed blower motor, the Bryant 353AAV improves airflow and overall system efficiency. This motor adjusts the speed based on the heating needs of the home, providing steady, even distribution of warm air. This feature reduces noise levels typically associated with traditional furnaces and enhances overall comfort by minimizing hot and cold spots.

The 353AAV also boasts an impressive Annual Fuel Utilization Efficiency (AFUE) rating, often exceeding 90%. This high AFUE indicates that a significant portion of fuel is converted into usable heat, making it an environmentally-friendly option that also saves homeowners money on utility bills. Additionally, this model is compatible with smart thermostat technology, allowing for easy and efficient climate control through mobile devices.

Durability and reliability are also key characteristics of the Bryant 353AAV. The furnace is constructed with high-quality materials, including a corrosion-resistant heat exchanger and a sturdy cabinet designed to withstand the test of time. Bryant backs the 353AAV with a 10-year limited warranty on parts, providing peace of mind for homeowners.

Finally, the Bryant 353AAV is designed with quiet operation in mind. Features like the insulated cabinet and noise-reducing blower motor contribute to a quieter home environment, making this model ideal for families and those sensitive to noise.

In summary, the Bryant 353AAV combines energy efficiency, advanced technology, and robust construction to offer homeowners a reliable heating solution. With its two-stage heating, variable-speed blower motor, high AFUE rating, and quiet operation, this gas furnace stands out as a top choice in residential heating systems.