Allied Air Enterprises A80UH2V & 80G1UH2V Unit Dimensions inches mm, Front View Side View

Page 2

A80UH2V & 80G1UH2V Unit Dimensions - inches (mm)

1NOTE - 20C and 20D size units installed in upflow applications that require air volumes of 1800 cfm (850 L/s or greater must have one of the following:

1.Return air from single side transition will accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter. (Required to maintain proper air velocity.)

2.Single side return air with optional RAB Return Air Base

3.Return Air from bottom and one side.

4.Return air from both sides.

5.Return air from bottom.

2Flue outlet may be horizontal but furnace must be vented vertically.

3Optional external side return air filter kit cannot be used with the optional RAB Return Air Base.

*Consider sizing requirements for optional IAQ equipment before cutting side return opening.

FRONT VIEW

 

 

 

 

 

SIDE VIEW

 

 

Model

 

A

 

B

 

C

 

D

 

 

 

 

 

 

 

 

A801UH2V/80G1UH2V

in.

mm

in.

mm

in.

mm

in.

mm

 

070-12

14-1/2

368

13-3/8

340

13

330

4-3/4

121

090-12

17-1/2

446

16-3/8

416

16

406

6-1/4

159

090-16

090-20

 

 

 

 

 

 

 

 

110-20

21

533

19-7/8

504

19-1/2

495

8

203

135-20

24-1/2

622

23-3/8

546

23

584

9-3/4

248

Page 2 of 41

Issue 1034

506471-01

Image 2
Contents Table of Contents A80UH2V & 80G1UH2VA80UH2V & 80G1UH2V Unit Dimensions inches mm Front View Side ViewExploded View A80UH2V & 80G1UH2V Gas Furnace Safety InformationInstalled Locations Shipping and Packing ListTemperature Rise Installed in Combination with a Cooling CoilProduct Contains Fiberglass Wool Combustion, Dilution & Ventilation AirAir from Outside Unconfined SpaceConfined Space Equipment in Confined Space ALL AIR from Outside Upflow Applications Setting EquipmentUpflow Application Installation Clearances Return Air Upflow Applications Front ViewReturn Air Horizontal Applications Removing the Bottom PanelHorizontal Applications Duct System Horizontal Application Unit installed on PlatformFilters Supply Air PlenumUpflow Position VentingMounting Screws Location Horizontal Right Position Horizontal PositionHorizontal Left Position Vent Connection Venting Using a Masonry ChimneyCommon Venting Using Metal Lined Masonry Chimney General Venting Requirements Issue Issue 506471-01 Issue Issue 506471-01 Issue Removal of the Furnace from Common Vent Carbon Monoxide Poisoning HazardGas Pipe Capacity ft³/hr m³/hr Gas PipingGas Supply Horizontal Applications Possible Gas Piping Configurations Electrical Interior MAKE-UP BOX InstallationLeak Check Electrostatic Discharge ESDGenerator Use Voltage Requirements Electrical WiringIndoor Blower Speeds Thermostat Automatic Heat Staging Jumper Electronic Air CleanerVariable Speed Features HumidifierCooling Mode Heating ModeAdjusting Airflow To Shut Down Furnace Lighting InstructionsWhat to do if you smell gas Heat Pump Single Stage CoolingTwo Stage Cooling Call for Fan 1st Stage 2nd Stage W1/W2 Heat CallHigh Heat W2 Call GAS Valve Shown in on Position Checking and Adjusting Gas InputControls Input Manifold Pressure SettingsBTU/HR Lubrication BurnersTypical Flame Appearance High Heat State Green LED TroubleshootingFailure Codes Red LED LEDBurner Group Control Group Heat Exchanger GroupBlower Group Wiring Diagram WHT RED RED/BLK ORN BLU VLTTypical Field Wiring Diagram START-UP & Performance Check List Unit SET UP Unit Operation

80G1UH2V, A80UH2V specifications

Allied Air Enterprises has made a significant mark in the HVAC industry with its innovative and high-performance heating and cooling solutions. Among its impressive lineup, the Allied Air Enterprises 80G1UH2V and A80UH2V models stand out for their efficiency, reliability, and advanced features.

The 80G1UH2V is a two-stage gas furnace that operates on natural gas or propane. With an efficiency rating of up to 80%, it provides excellent heating performance while contributing to cost savings on utility bills. Its durable cabinet design ensures long-lasting performance and protection from harsh weather conditions, making it ideal for a variety of home environments.

One of the key features of the 80G1UH2V is its two-stage heating capability. This technology allows the furnace to operate at a lower capacity to maintain consistent temperatures during milder weather, reducing energy consumption and noise. When the temperature drops significantly, the furnace automatically shifts to high capacity, delivering the required heat promptly. This flexibility not only creates a more comfortable living space but also enhances energy efficiency.

The A80UH2V model shares similar traits with the 80G1UH2V but offers some additional features. It includes a variable-speed blower motor that optimizes airflow throughout the home. This innovation not only increases comfort levels but also facilitates quieter operation. The A80UH2V's advanced control system provides precise temperature management and can be integrated easily with smart home systems for enhanced automation.

Both models are designed to operate quietly, with noise levels minimized through improved insulation and sound-dampening technologies. This makes them suitable for residential applications, where comfort and peace are a priority. Additionally, they come equipped with a self-diagnostic control board that makes troubleshooting and maintenance simpler and more efficient.

Durability is another critical characteristic of both the 80G1UH2V and A80UH2V. They feature a robust heat exchanger made from high-quality materials, enhancing longevity and reliability. With these models, homeowners can expect reliable performance for years with minimal upkeep.

In summary, the Allied Air Enterprises 80G1UH2V and A80UH2V models deliver exceptional heating solutions through advanced technology, efficiency, and reliability. Their innovative features cater to the modern homeowner's need for comfort, control, and energy savings, making them excellent choices for residential heating needs.