Allied Air Enterprises A80UH2V Horizontal Application Unit installed on Platform, Filters

Page 12

Horizontal Application

Unit installed on Platform

Figure 14

WARNING

Improper installation of the furnace can result in personal injury or death. Combustion and flue products must never be allowed to enter the return air system or the living space. Use screws and joint tape to seal the return air system to the furnace.

In platform installations with bottom return air, the furnace should be sealed airtight to the return air plenum. A door must never be used as a portion of the return air duct system. The base must provide a stable support and an airtight seal to the furnace. Allow absolutely no sagging, cracks, gaps, etc..

The return and supply air duct systems must never be connected to or from other heating devices such as a fireplace or stove, etc.. Fire, explosion, carbon monoxide poisoning, personal injury and/or property damage could result.

WARNING

The inner blower panel must be securely in place when the blower and burners are operating. Gas fumes, which could contain carbon monoxide, can be drawn into living space resulting in personal injury or death.

Filters

This unit is not equipped with a filter or rack. A field provided high velocity filter is required for the unit to operate properly. Table 1 lists recommended filter sizes.

A filter must be in place any time the unit is operating.

Table 1

Duct System

Use industry approved standards (such as those published by Air Conditioning Contractors of America or American Society of Heating, Refrigerating and Air Conditioning Engineers) to size and install the supply and return air duct system. This will result in a quiet and low static system that has uniform air distribution.

NOTE: Do not operate the furnace in the heating mode with an external static pressure that exceeds 0.8 inches w.c. Higher external static pressures may cause erratic limit operation.

Supply Air Plenum

If the furnace is installed without a cooling coil, a removable access panel must be installed in the supply air duct. The access panel should be large enough to permit inspection (either by smoke or reflected light) of the heat exchanger for leaks after the furnace is installed. The furnace access panel must always be in place when the furnace is operating and it must not allow leaks into the supply air duct system.

Return Air Plenum

NOTE: Return air must not be drawn from a room where this furnace, or any other gas fueled appliance (i.e., water heater), or carbon monoxide producing device (i.e., wood fireplace) is installed.

When return air is drawn from a room, a negative pressure is created in the room. If a gas appliance is operating in a room with negative pressure, the flue products can be pulled back down the vent pipe and into the room. This reverse flow of the flue gas may result in incomplete combustion and the formation of carbon monoxide gas. This toxic gas might then be distributed throughout the house by the furnace duct system.

In upflow applications, the return air can be brought in through the bottom or either side of the furnace. If a furnace with bottom return air is installed on a platform, make an airtight seal between the bottom of the furnace and the platform to ensure that the unit operates properly and safely. Use fiberglass sealing strips, caulking, or equivalent sealing method between the plenum and the furnace cabinet to ensure a tight seal. If a filter is installed, size the return air duct to fit the filter frame.

Page 12 of 41

Issue 1034

506471-01

Image 12
Contents Table of Contents A80UH2V & 80G1UH2VA80UH2V & 80G1UH2V Unit Dimensions inches mm Front View Side ViewExploded View Safety Information Installed LocationsA80UH2V & 80G1UH2V Gas Furnace Shipping and Packing ListTemperature Rise Installed in Combination with a Cooling CoilProduct Contains Fiberglass Wool Combustion, Dilution & Ventilation AirUnconfined Space Confined SpaceAir from Outside Equipment in Confined Space ALL AIR from Outside Setting Equipment Upflow Application Installation ClearancesUpflow Applications Return Air Upflow Applications Front ViewRemoving the Bottom Panel Horizontal ApplicationsReturn Air Horizontal Applications Horizontal Application Unit installed on Platform FiltersDuct System Supply Air PlenumVenting Mounting Screws LocationUpflow Position Horizontal Position Horizontal Left PositionHorizontal Right Position Venting Using a Masonry Chimney Common Venting Using Metal Lined Masonry ChimneyVent Connection General Venting Requirements Issue Issue 506471-01 Issue Issue 506471-01 Issue Removal of the Furnace from Common Vent Carbon Monoxide Poisoning HazardGas Piping Gas SupplyGas Pipe Capacity ft³/hr m³/hr Horizontal Applications Possible Gas Piping Configurations Interior MAKE-UP BOX Installation Leak CheckElectrical Electrostatic Discharge ESDElectrical Wiring Indoor Blower SpeedsGenerator Use Voltage Requirements Automatic Heat Staging Jumper Electronic Air Cleaner Variable Speed FeaturesThermostat HumidifierCooling Mode Heating ModeAdjusting Airflow Lighting Instructions What to do if you smell gasTo Shut Down Furnace Single Stage Cooling Two Stage CoolingHeat Pump 1st Stage 2nd Stage W1/W2 Heat Call High Heat W2 CallCall for Fan Checking and Adjusting Gas Input ControlsGAS Valve Shown in on Position Manifold Pressure Settings BTU/HRInput Burners Typical Flame AppearanceLubrication Troubleshooting Failure Codes Red LEDHigh Heat State Green LED LEDControl Group Heat Exchanger Group Blower GroupBurner Group Wiring Diagram WHT RED RED/BLK ORN BLU VLTTypical Field Wiring Diagram START-UP & Performance Check List Unit SET UP Unit Operation

80G1UH2V, A80UH2V specifications

Allied Air Enterprises has made a significant mark in the HVAC industry with its innovative and high-performance heating and cooling solutions. Among its impressive lineup, the Allied Air Enterprises 80G1UH2V and A80UH2V models stand out for their efficiency, reliability, and advanced features.

The 80G1UH2V is a two-stage gas furnace that operates on natural gas or propane. With an efficiency rating of up to 80%, it provides excellent heating performance while contributing to cost savings on utility bills. Its durable cabinet design ensures long-lasting performance and protection from harsh weather conditions, making it ideal for a variety of home environments.

One of the key features of the 80G1UH2V is its two-stage heating capability. This technology allows the furnace to operate at a lower capacity to maintain consistent temperatures during milder weather, reducing energy consumption and noise. When the temperature drops significantly, the furnace automatically shifts to high capacity, delivering the required heat promptly. This flexibility not only creates a more comfortable living space but also enhances energy efficiency.

The A80UH2V model shares similar traits with the 80G1UH2V but offers some additional features. It includes a variable-speed blower motor that optimizes airflow throughout the home. This innovation not only increases comfort levels but also facilitates quieter operation. The A80UH2V's advanced control system provides precise temperature management and can be integrated easily with smart home systems for enhanced automation.

Both models are designed to operate quietly, with noise levels minimized through improved insulation and sound-dampening technologies. This makes them suitable for residential applications, where comfort and peace are a priority. Additionally, they come equipped with a self-diagnostic control board that makes troubleshooting and maintenance simpler and more efficient.

Durability is another critical characteristic of both the 80G1UH2V and A80UH2V. They feature a robust heat exchanger made from high-quality materials, enhancing longevity and reliability. With these models, homeowners can expect reliable performance for years with minimal upkeep.

In summary, the Allied Air Enterprises 80G1UH2V and A80UH2V models deliver exceptional heating solutions through advanced technology, efficiency, and reliability. Their innovative features cater to the modern homeowner's need for comfort, control, and energy savings, making them excellent choices for residential heating needs.