Carrier 58TMA → -Horizontal Installation on Blocks, Furnace Casing Width Filters

Page 9

A95235

Fig. 10—Horizontal Installation on Blocks

AIRFLOW

12

4D

FIELD-SUPPLIED￿

FILTER RETAINERS

Fig. 11—Horizontal Filter Arrangement

Table 4—Filter Retainer (In.)

FURNACE CASING WIDTH

FILTERS

D

14-3/16

(2) 14 X 20 X 1

14-3/8

17-1/2

(2) 14 X 20 X 1

13-3/8

21

(2) 16 X 20 X 1

11-5/8

24-1/2

(2) 16 X 20 X 1

10-1/4

 

 

 

If flexible connector is required or allowed by authority having jurisdiction, black iron pipe shall be installed at gas valve and extend a minimum of 2 in. outside furnace casing.

Use the proper length of pipes to avoid stress on gas control manifold. A failure to follow this warning could result in a gas leak causing fire, explosion, personal injury, or death.

Use a backup wrench at furnace gas control when connecting gas pipe to furnace to avoid damaging gas controls or manifold.

Never purge a line into a combustion chamber. Never use matches, candles, flame, or other sources of ignition to check for gas leakage. Use a soap-and-water solution to check for gas leaks. A failure to follow this warning could result in fire, explosion, personal injury, or death.

Joint compounds (pipe dope) should be applied sparingly and only to male threads of joints. This pipe dope must be resistant to action of propane gas.

AIRFLOW

INSTALLATION￿

POSITION￿

OF FILTERS

RETURN-AIR￿

PLENUM

ACCESS DOOR

Fig. 12—Downflow Filter Arrangement A88486

Table 5—Maximum Capacity of Pipe*

NOMINAL

INTERNAL

 

LENGTH OF PIPE (FT)

 

IRON PIPE

DIAMETER

 

 

 

 

 

 

10

 

20

30

40

50

SIZE (IN.)

(IN.)

 

1/2

0.622

175

 

120

97

82

73

3/4

0.824

360

 

250

200

170

151

1

1.049

680

 

465

375

320

285

1-1/4

1.380

1400

 

950

770

660

580

1-1/2

1.610

2100

 

1460

1180

990

900

 

 

 

 

 

 

 

 

*Cubic ft of gas per hr for gas pressures of 0.5 psig (14-in. wc) or less, and a supply line pressure drop of 0.5-in. wc (based on a 0.60 specific gravity gas). Ref: Table 10-2, NFPA 54-1996.

Install accessible manual shutoff valve upstream of furnace gas controls and within 72 in. of furnace. A 1/8-in. NPT plugged tapping is provided on gas value for test gage connection. Installation of additional 1/8-in. NPT plugged tapping, accessible for test gage connection, installed immediately upstream of gas supply connection to furnace and downstream of manual shutoff valve is not required. Place ground joint union between gas control manifold and manual shutoff.

Install sediment trap in riser leading to furnace. The trap can be installed by connecting a tee to riser leading from furnace. Connect capped nipple into lower end of tee. The capped nipple should extend below level of gas controls. (See Fig. 13.)

Piping should be pressure tested in accordance with local and national plumbing and gas codes before furnace has been attached. If test pressure exceeds 0.5 psig (14-in. wc), the gas supply pipe must be disconnected from furnace and capped before pressure test. If test pressure is equal to or less than 0.5 psig (14-in. wc), turn off electric shutoff switch located on the gas valve before test. (See Fig. 13.) It is recommended that ground joint union be loosened before pressure testing.

After all connections have been made, purge lines and check for gas leakage with regulated gas supply pressure.

9

Image 9
Contents SUPPLY-AIR Plenum Installation Electrostatic Discharge ESD PrecautionsUnit Size Vent Conn SHIP. WT Dimensional Drawing DimensionsMinimum Inches Clearance to Combustible Construction Location Relative to Cooling Equipment GeneralHazardous Locations Unconfined SpaceConfined Space Air for Combustion Ventilation from Outdoors → Downflow InstallationFree Area Of Combustion Air Opening Installation on Combustible FloorInput Furnace Plenum Opening Floor Opening CasingConstruct Working Platform Install Furnace→ -Horizontal Crawlspace Installation on Hanger Rods Typical Attic Installation→ -Horizontal Installation on Blocks Furnace Casing Width FiltersNominal Internal Length of Pipe FT Iron Pipe Diameter Size Accessories WiringSetup Switch Description Electrical DataAmps Gage FT‡ CKT BKR AMPS† Desired Heating Setup Switch Mode Blower OFF → -Setup Switches on Control Center Factory SettingsDelay SEC Sequence of OperationConnection Diagram → -Unit Wiring DiagramPage Page Adjustments START-UP ProceduresUnited States Altitude Derate Multiplier for U.S.AExample CanadaBTU/CU FT 725 1.6 625 1.4 → -Redundant Automatic Gas Control Valve Gas Rate Cu Ft/HrCheck Safety Controls Speed SelectionColor Speed AS Shipped Checklist Service Training

58TMA specifications

The Carrier 58TMA is a high-efficiency gas furnace designed to provide reliable heating solutions for residential spaces. As part of Carrier's extensive range of heating products, the 58TMA series exemplifies innovation in home comfort technology, offering advanced features that cater to both performance and energy savings.

One of the standout features of the Carrier 58TMA is its variable-speed blower motor. This technology allows for precise airflow control, ensuring consistent temperatures throughout the home while minimizing energy consumption. The variable-speed operation also contributes to quieter operation, enhancing indoor comfort without the disruptive noise commonly associated with traditional furnaces.

The furnace operates with a multi-stage gas valve, enhancing its efficiency. With the ability to modulate heating output based on demand, the 58TMA ensures that the home is heated only as needed. This not only improves energy efficiency but also maintains a more stable and comfortable indoor environment. The combination of the multi-stage gas valve and variable-speed blower results in significant energy cost savings for homeowners.

Another impressive aspect of the Carrier 58TMA is its high Annual Fuel Utilization Efficiency (AFUE) rating. With an AFUE of up to 96%, this gas furnace is engineered to convert a majority of the fuel it consumes into heat, reducing waste and lowering utility bills. Such efficiency ratings make the 58TMA an attractive option for eco-conscious consumers looking to minimize their carbon footprint.

In addition to efficiency and performance, the Carrier 58TMA is designed with durability in mind. The unit features a robust cabinet made from high-quality materials, along with an advanced heat exchanger that ensures long-lasting performance. Moreover, it comes equipped with an advanced electrical ignition system, providing reliable start-up under various conditions without the need for a pilot light.

For added convenience, the 58TMA can be integrated with Carrier's Smart Thermostat technology. This allows homeowners to monitor and adjust their heating settings remotely, facilitating an optimized comfort experience while further enhancing energy savings.

Overall, the Carrier 58TMA's combination of efficiency, advanced technology, and durability makes it a standout option in the market for homeowners seeking dependability and energy savings in their heating solutions. With its innovative features and user-friendly operation, the 58TMA represents a significant advancement in modern furnace design, providing peace of mind and comfort year after year.