Superior VFGL-18MSN-4 SERIES* dimensions Unvented GAS LOG Room Heater Specification Chart, Btu/Hr

Page 10

10

UNVENTED GAS LOG ROOM HEATER SPECIFICATION CHART

Model No.

Valve Operation

BTU/hr Input

Gas Type

 

 

 

 

VFGL - 18 MSN-4

Manual*

14,000 - 25,000

Natural

 

 

 

 

VFGL - 18 MSP-4

Manual*

14,000 - 25,000

Propane/LPG

 

 

 

 

VFGL - 24 MSN-4

Manual*

17,000 - 32,000

Natural

VFGL - 24 MSP-4

Manual*

17,000 - 32,000

Propane/LPG

 

 

 

 

VFGL - 28 MSN-4

Manual*

17,000 - 32,000

Natural

VFGL - 28 MSP-4

Manual*

17,000 - 32,000

Propane/LPG

VFGL - 18 VSN-4

Millivolt

19,500 - 25,000

Natural

 

 

 

 

VFGL - 18 VSP-4

Millivolt

19,500 - 25,000

Propane/LPG

VFGL - 24 VSN-4

Millivolt

25,000 - 32,000

Natural

 

 

 

 

VFGL - 24 VSP-4

Millivolt

25,000 - 32,000

Propane/LPG

 

 

 

 

VFGL - 28 VSN-4

Millivolt

25,000 - 32,000

Natural

 

 

 

 

VFGL - 28 VSP-4

Millivolt

25,000 - 32,000

Propane/LPG

 

 

 

 

* Manual control models are also design certified for use as vented gas log sets.

UNVENTED GAS LOG ROOM HEATER TECHNICAL CHART

 

BTU/HR

 

 

Regulator

Gas Inlet

Valve

Model No.

High

Gas Type

Ignition

Pres. Setting

Pressure**

Operation

 

 

 

 

 

 

 

VFGL - 18N

25,000

Natural

Piezo

5" w.c.

Max. 10.5" w.c.

Manual*/Millivolt

 

 

 

 

 

Min. 6" w.c.

 

VFGL - 18P

25,000

Propane/LPG

Piezo

10" w.c.

Max. 13" w.c.

Manual*/Millivolt

 

 

 

 

 

Min. 11" w.c.

 

VFGL - 24N

32,000

Natural

Piezo

5" w.c.

Max. 10.5" w.c.

Manual*/Millivolt

 

 

 

 

 

Min. 6" w.c.

 

VFGL - 24P

32,000

Propane/LPG

Piezo

10" w.c.

Max. 13" w.c.

Manual*/Millivolt

 

 

 

 

 

Min. 11" w.c.

 

VFGL - 28N

32,000

Natural

Piezo

5" w.c.

Max. 10.5" w.c.

Manual*/Millivolt

 

 

 

 

 

Min. 6" w.c.

 

VFGL - 28P

32,000

Propane/LPG

Piezo

10" w.c.

Max. 13" w.c.

Manual*/Millivolt

 

 

 

 

 

Min. 11" w.c.

 

 

 

 

 

 

 

 

*Manual control models are also design certified for use as vented gas log sets.

**For the purpose of input adjustment.

Image 10
Contents For USE only with Decorative Type Unvented Room Heaters Consumer Retain this manual for future referenceUnvented Gas Log Room Heaters 903623 REV. M 12/2007 Table of Contents Combustion and Ventilation AIR CodesMassachusetts And New York Require- ments MassachusettsClearances PreinstallationCheck Gas Type ExampleAt least Requirements for Safe InstallationNoncombustible Material Heights and Mantel Location Or moreQualified gas appliance installer must install this heater InstallationConsult all local codes Assembling the Logs Gas Pressure CheckPeriodically verify proper positioning of all logs Operation and Care of Your Appliance Cleaning and ServicingReplacement Parts LHPOptional Equipment Unvented GAS LOG Room Heater Technical Chart Unvented GAS LOG Room Heater Specification ChartBTU/HR Possible Cause Remedy TroubleshootingObserved Problem GASWhat to do if YOU Smell GAS For Your Safety Read Before LightingOperating Instructions Manual Control Models Lighting InstructionsPiezo Flame Adjustment Locate gas control knob and piezo Stop! Read the safety information aboveOperating Instructions OFF position FigureTurn Control Knob to OFF Position Pilot Pilot Location Turn Control Knob to on PositionReplacement Parts List 18N/18P 24N/24P 28N/28P DescriptionReplacement Parts Page Page 903623 REV. M 12/2007 Orange, CA