Superior VFGL-24VSN-4 SERIES Replacement Parts List, 18N/18P 24N/24P 28N/28P Description

Page 16

16

REPLACEMENT PARTS LIST

 

 

 

 

18N/18P

 

24N/24P

 

28N/28P

No.

Description

 

Part No.

 

Part No.

 

Part No.

1.

Valve - Manual (Natural)

 

110331

 

110331

 

110331

 

 

 

 

 

 

 

 

 

Valve - Manual (Propane, L.P.G.)

 

110331

 

110331

 

110331

 

 

 

 

 

 

 

 

2.

Valve, Millivolt (Natural)

 

903489

 

903489

 

903489

 

 

 

 

 

 

 

 

 

Valve, Millivolt (Propane, L.P.G.)

 

901917

 

901917

 

901917

 

 

 

 

 

 

 

 

 

3.

Pilot

(Natural)

 

110345

 

110345

 

110345

 

 

 

 

 

 

 

 

 

 

Pilot

(Propane, L.P.G.)

 

110341

 

110341

 

110341

 

 

 

 

 

 

 

 

4.

Pilot, Millivolt (Natural)

 

110344

 

110344

 

110344

 

 

 

 

 

 

 

 

 

Pilot, Millivolt (Propane, L.P.G.)

 

901915

 

901915

 

901915

 

 

 

 

 

 

 

 

5.

Regulator (Natural)

 

110351

 

110351

 

110351

 

 

 

 

 

 

 

 

 

Regulator (Propane, L.P.G.)

 

110352

 

110352

 

110352

 

 

 

 

 

 

 

 

6.

Front Burner

 

110281

 

110282

 

110282

 

 

 

 

 

 

 

 

7.

Rear Burner (Natural)

 

113301

 

110302

 

110302

 

 

 

 

 

 

 

 

 

Rear Burner (Propane, L.P.G.)

 

113301

 

110302

 

110302

 

 

 

 

 

 

 

 

8.

Crossover Burner

 

110321

 

110321

 

110321

 

 

 

 

 

 

 

 

 

9.

Piezo

 

 

111061

 

111061

 

111061

 

 

 

 

 

 

 

 

10.

Piezo Wire

 

110361

 

110361

 

110361

 

 

 

 

 

 

 

 

11.

Log Assembly – Split Oak

 

100104

 

100105

 

100106

 

 

 

 

 

 

 

 

12.

Control Knob - Manual

 

110401

 

110401

 

110401

 

 

 

 

 

 

 

 

13.

Injector, Burner (Natural)

 

110381

 

110383

 

110383

 

 

 

 

 

 

 

 

 

Injector, Burner (Propane, L.P.G.)

 

110382

 

110384

 

110384

 

 

 

 

 

 

 

 

14.

Injector, Crossover Burner (Natural)

 

110387

 

110387

 

110387

 

 

 

 

 

 

 

 

 

Injector, Crossover Burner (Propane, L.P.G.)

 

110388

 

110388

 

110388

 

 

 

 

 

 

 

 

 

Image 16
Contents For USE only with Decorative Type Unvented Room Heaters Consumer Retain this manual for future referenceUnvented Gas Log Room Heaters 903623 REV. M 12/2007 Table of Contents Codes Massachusetts And New York Require- mentsCombustion and Ventilation AIR MassachusettsPreinstallation Check Gas TypeClearances ExampleRequirements for Safe Installation Noncombustible Material Heights and Mantel LocationAt least Or moreQualified gas appliance installer must install this heater InstallationConsult all local codes Assembling the Logs Gas Pressure CheckPeriodically verify proper positioning of all logs Cleaning and Servicing Replacement PartsOperation and Care of Your Appliance LHPOptional Equipment Unvented GAS LOG Room Heater Technical Chart Unvented GAS LOG Room Heater Specification ChartBTU/HR Troubleshooting Observed ProblemPossible Cause Remedy GASFor Your Safety Read Before Lighting Operating Instructions Manual Control ModelsWhat to do if YOU Smell GAS Lighting InstructionsPiezo Flame Adjustment Stop! Read the safety information above Operating InstructionsLocate gas control knob and piezo OFF position FigureTurn Control Knob to OFF Position Pilot Pilot Location Turn Control Knob to on PositionReplacement Parts List 18N/18P 24N/24P 28N/28P DescriptionReplacement Parts Page Page 903623 REV. M 12/2007 Orange, CA