Superior VFGL-24MSP-4 SERIES* Operating Instructions, Stop! Read the safety information above

Page 14

OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY

RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.This heater has a pilot which must be lit by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE OPERATING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Forced or attempted repair may result in a fire or explosion.

D.Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

14

 

 

LIGHTING INSTRUCTIONS

 

1. Stop! Read the safety information above.

 

8. With the control knob pressed in, push in and release the

 

 

piezo igniter button to light the pilot.

2.Make sure manual shut-off valve is fully open.

 

 

 

9.

Hold the control knob in for a further 10 seconds to prevent

3.

Locate gas control knob and piezo.

 

 

the flame failure detector from shutting off the gas while the

 

 

 

 

probe is warming up.

 

 

4.

Depress control knob in and turn clockwise

to the

10.

Release the control knob while turning counterclockwise

 

“OFF” position (Figure 19 ).

 

 

 

 

to the "ON" Position (Figure 22 ). Then adjust

 

 

 

 

5. Wait 5 minutes to clear out any gas. Then smell for gas,

 

"HI"-"LOW" knob to prefered setting.

 

 

 

 

 

 

 

including near the floor. If you smell gas, STOP! Follow “B” in

 

If the knob does not pop out when released, stop and

 

the safety information above. If you do not smell gas, go to the

 

 

 

immediately call your service technician or gas supplier.

 

next step.

 

 

 

 

 

 

 

 

6.

The pilot is located on the right side in front of the burner

 

If the pilot will not stay lit after several tries, depress and

 

turn the gas control knob clockwise

to “OFF”

 

(Figure 20 ).

 

 

and wait 30 seconds. Depress and turn

 

7.

Depress control knob in and turn counterclockwise

 

 

knob counterclockwise

to

 

 

 

“IGN” and press igniter button again. If

 

 

to the “PILOT” position (Figure 21 ). Press the control knob all

 

your pilot does not relight depress and

 

 

the way in for 5 seconds.

 

 

turn control knob clockwise

 

 

 

Note: If you are running the heater for the first time it will be

 

to “OFF” and call your service technician or gas supplier.

 

 

 

 

 

 

necessary to press the control knob all the way in for 30

11.

Wait 30 seconds before readjusting the heater when the

 

seconds to allow air to bleed out of the gas piping.

 

 

control knob has been turned down to a lower setting.

TO TURN OFF GAS TO APPLIANCE

1.Depress and turn control knob clockwise to the “OFF” position (Figure 19 ).

 

 

MANUAL MATCH LIGHTING PROCEDURE — EMERGENCY ONLY

 

 

 

 

1.

If the pilot cannot be lit with the piezo igniter, the heater can be

3.

Light the match and hold the flame to the end of the pilot and

 

manually lit with a match.

 

 

 

ignite the pilot.

2.

With the right hand, depress and turn the control knob

4.

Continue to hold control knob for an additional 10 seconds to

 

counterclockwise

to the “ON” position. Hold in the

 

insure pilot remains lit.

 

knob.

 

 

5.

Release the control while turning control knob to desired

 

 

 

 

 

 

 

 

 

setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 14
Contents Unvented Gas Log Room Heaters 903623 REV. M 12/2007 Consumer Retain this manual for future referenceFor USE only with Decorative Type Unvented Room Heaters Table of Contents Combustion and Ventilation AIR CodesMassachusetts And New York Require- ments MassachusettsClearances PreinstallationCheck Gas Type ExampleAt least Requirements for Safe InstallationNoncombustible Material Heights and Mantel Location Or moreConsult all local codes InstallationQualified gas appliance installer must install this heater Periodically verify proper positioning of all logs Gas Pressure CheckAssembling the Logs Operation and Care of Your Appliance Cleaning and ServicingReplacement Parts LHPOptional Equipment BTU/HR Unvented GAS LOG Room Heater Specification ChartUnvented GAS LOG Room Heater Technical Chart Possible Cause Remedy TroubleshootingObserved Problem GASWhat to do if YOU Smell GAS For Your Safety Read Before LightingOperating Instructions Manual Control Models Lighting InstructionsPiezo Flame Adjustment Locate gas control knob and piezo Stop! Read the safety information aboveOperating Instructions OFF position FigureTurn Control Knob to OFF Position Pilot Pilot Location Turn Control Knob to on PositionReplacement Parts List 18N/18P 24N/24P 28N/28P DescriptionReplacement Parts Page Page 903623 REV. M 12/2007 Orange, CA