Superior DR500 manual Maintenance Schedule, Maintenance Task Accomplishing Person Procedure

Page 5

Maintenance Schedule

Annually (Before the onset of the Burning Season)

 

Maintenance Task

 

Accomplishing Person

 

Procedure

 

 

 

 

 

 

 

 

 

 

 

Inspecting/Cleaning Burner, Logs

 

Qualified Service Technician

Inspect valve and ensure it is properly operating.

 

 

and Controls

 

 

 

Check piping for leaks. Vacuum the control

 

 

 

 

 

 

 

compartment, fireplace logs and burner area.

 

 

 

 

 

 

 

 

 

 

 

Check Flame Patterns and Flame Height

 

Qualified Service Technician

Refer to Figure 7 (D, DT, DR-500), 8 (D,

 

 

 

 

 

 

 

DT,DR-600) or 9 (D,DT,DR-800) on page 7

 

 

 

 

 

 

 

and verify the flame pattern and height displayed

 

 

 

 

 

 

 

by the appliance conforms to the picture. Flames

 

 

 

 

 

 

 

must not impinge on the logs.

 

 

 

 

 

 

 

 

 

 

 

Inspecting/Cleaning Pilot and Burner

 

Qualified Service Technician

Refer to Figure 10 (SIT Millivolt), Figure

 

 

 

 

 

 

 

11 (Honeywell Millivolt) or Figure 12 (Elec-

 

 

 

 

 

 

 

tronic) on page 8. Remove any surface

 

 

 

 

 

 

 

build-up on pilot and burner assembly. Wipe

 

 

 

 

 

 

 

the pilot nozzles, ignitor/flame rod and hood.

 

 

 

 

 

 

 

Ensure the pilot flame engulfs the flame

 

 

 

 

 

 

 

sensor as shown.

 

 

 

 

 

 

 

 

 

 

 

Checking Vent System

 

Qualified Service Technician

Inspect the vent system at the top and at the

 

 

 

 

 

 

 

base (within the firebox) for signs of blockage

 

 

 

 

 

 

 

or obstruction. Look for any signs of disloca-

 

 

 

 

 

 

 

tion of the vent components.

 

 

 

 

 

 

 

 

 

 

 

Appliance Checkout

 

Qualified Service Technician

Perform the appropriate appliance checkout

 

 

 

 

 

 

 

procedure detailed in this manual.

 

 

 

 

 

 

 

 

 

 

 

Replacing Rockwool Ember Materials

 

Homeowner/Qualified Services Technician

Remove old ember materials and vacuum the

 

 

 

 

 

 

 

screened rockwool placement area. Place new

 

 

 

 

 

 

 

rockwool as described in this document.

 

 

 

 

 

 

 

 

 

 

 

Periodically (After the Burning Season)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance Task

 

Accomplishing Person

 

Procedure

 

 

 

 

 

 

 

 

 

 

Cleaning Firebox Interior

Homeowner

 

Carefully remove logs, Rockwool and volca-

 

 

 

 

 

 

 

nic stone if used. Vacuum out interior of the

 

 

 

 

 

 

 

firebox. Clean firebox walls and log grate.

 

 

 

 

 

 

 

Replace logs, Rockwool and volcanic stone

 

 

 

 

 

 

 

as detailed in this manual.

 

 

 

 

 

 

 

 

 

 

Check Flame Patterns and Flame Height

Homeowner

 

Refer to Figure 7 (D, DT, DR-500), 8 (D,

 

 

DT,DR-600) or 9 (D,DT,DR-800) on page 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and verify the flame pattern and height dis-

 

 

 

 

 

 

 

played by the appliance conforms to the picture.

 

 

 

 

 

 

 

Flames must not impinge on the logs.

 

 

 

 

 

 

 

 

 

 

Checking Vent System

Homeowner

 

Inspect the vent system at the top and at the

 

 

 

 

 

 

 

base (within the firebox) for signs of block-

 

 

 

 

 

 

 

age or obstruction. Look for any signs of

 

 

 

 

 

 

 

dislocation of the vent components.

 

 

 

 

 

 

 

 

 

 

Cleaning Front Glass Enclosure Panel

Homeowner

 

Clean as necessary following the directions

 

 

 

 

 

 

 

provided in this manual. DO NOT TOUCH OR

 

 

 

 

 

 

 

ATTEMPT TO CLEAN GLASS WHILE HOT.

 

 

 

 

 

 

 

 

 

5

Image 5
Contents DR-500 Model Shown Retain These Instructions For Future ReferenceDT-500CEN DR-600CEP DR-500CEP DT-800CENCongratulations Table of ContentsBD-R Gas Controls/Control Compartment AccessOperation and Care of Your Appliance When IT is HOT Variable Flame Height AdjustmentGlass Cleaning MaintenanceMaintenance Task Accomplishing Person Procedure Maintenance ScheduleRefer to SIT Millivolt, Figure Refer to D, DT, DR-500, 8 DBurner Adjustments Front Glass Enclosure Panel, Removal and InstallationReinstall the top louver assembly or radiant panel AdjustmentFire shown with optional Brick Liner Kit Log PlacementDT, DR-600 Model DT, DR-500 ModelElectronic Appliance Checkout Glowing Embers Rockwool PlacementReplacement Parts WarrantyProduct Reference Information LHPAccessory Components Brick Liner Kits Catalog No Clean Face Panel Kits Model No Catalog NoLouver Kits Catalog No Door Frame Kits Catalog NoLighting Instructions Lighting Instructions Honeywell and SIT Millivolt GAS ValveTo Turn OFF GAS to Appliance What to do if YOU Smell GASPosition d’arrêt OFF Instructions DallumagePour Fermer LE GAZ QUI Alimente L’APPAREIL What to do if YOU Smell GAS Lighting Instructions ElectronicTo Shut OFF Front ViewInstructions D’ALLUMAGE Instructions D’ALLUMAGE ElectronicPour Éteindre L’APPAREIL Pour Fermer LE GAZ QUI Alimente L’APPAREILOn page 8- Honeywell Symptom Possible Causes Corrective ActionCheck vent system for obstructions Troubleshooting the Electronic Ignition SystemGAS Controls SIT Millivolt Replacement Parts ListGAS Controls Honeywell Millivolt GAS Controls ElectronicDT, DR-500 DR, DR-800 3431725,032M REV. H 11/2004