Superior DR500 manual Log Placement, Fire shown with optional Brick Liner Kit, DT, DR-600 Model

Page 7

 

 

Adjusting

 

 

 

Set Screw

 

 

 

Adjustment Rod

 

 

Up (Fully Open

 

 

 

Position)

Venturi

 

 

 

Air Shutter

 

 

Adjustment Rod Down

 

(minimum air

 

opening position)

 

 

FACTORY AIR

 

 

SHUTTER SETTING

 

 

inches (mm)

 

Models

 

Applications

Applications

Gas

using the

using the

D, DT

Type

Appliance

Appliance

& DR

 

Top Vent

Rear Vent

 

 

500

Nat.

3/32 (2.38)

3/32 (2.38)

Prop.

1/8 (3.18)

3/8 (9.52)

 

600

Nat.

3/32 (2.38)

3/32 (2.38)

Prop.

3/8 (9.52)

3/8 (9.52)

 

800

Nat.

3/16 (4.76)

3/16 (4.76)

Prop.

1/2 (13)

1/2 (13)

 

Figure 6

 

 

 

Log Placement

WARNING: LOGS GET VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OFF. HANDLE ONLY WHEN LOGS ARE COOL. TURN OFF ALL ELECTRICITY TO THE APPLIANCE BEFORE YOU INSTALL GRATE AND LOGS.

WARNING: THIS APPLIANCE IS NOT MEANT TO BURN WOOD. ANY AT- TEMPT TO DO SO COULD CAUSE IR- REPARABLE DAMAGE TO YOUR APPLI- ANCE AND PROVE HAZARDOUS TO YOUR SAFETY.

WARNING: THE SIZE AND POSITION ON THE LOG SET WAS ENGINEERED TO GIVE YOUR APPLIANCE A SAFE, RELIABLE AND ATTRACTIVE FLAME PATTERN. ANY ATTEMPT TO USE A DIFFERENT LOG SET IN THE FIREPLACE WILL VOID THE WARRANTY AND WILL RESULT IN INCOMPLETE COMBUSTION, SOOTING, AND POOR FLAME QUALITY.

Carefully position the ceramic fiber logs and twigs over the burner as shown in Figure 7 (D, DR, DR-500), 8 (D, DT,DR-600) or 9 (D, DT, DR-800).For more detailed placement instructions, refer to the LOG PLACEMENT GUIDE accompanying this document.

Proper twig placement is critical to prevent sooting. Twigs should be placed in the gaps between the flame peaks and should be positioned so that at no time they impinge the flames.

(Fire shown with optional Brick Liner Kit)

Figure 7

D, DT, DR-500 MODEL

Figure 8

D, DT, DR-600 MODEL

 

 

(Fire shown with optional Brick Liner Kit)

Figure 9

D, DT, DR-800 MODEL

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

7

Image 7
Contents DR-500CEP DT-800CEN Retain These Instructions For Future ReferenceDR-500 Model Shown DT-500CEN DR-600CEPCongratulations Table of ContentsOperation and Care of Your Appliance Gas Controls/Control Compartment AccessBD-R Maintenance Variable Flame Height AdjustmentWhen IT is HOT Glass CleaningRefer to D, DT, DR-500, 8 D Maintenance ScheduleMaintenance Task Accomplishing Person Procedure Refer to SIT Millivolt, FigureAdjustment Front Glass Enclosure Panel, Removal and InstallationBurner Adjustments Reinstall the top louver assembly or radiant panelDT, DR-500 Model Log PlacementFire shown with optional Brick Liner Kit DT, DR-600 ModelElectronic Appliance Checkout Glowing Embers Rockwool PlacementLHP WarrantyReplacement Parts Product Reference InformationAccessory Components Door Frame Kits Catalog No Clean Face Panel Kits Model No Catalog NoBrick Liner Kits Catalog No Louver Kits Catalog NoWhat to do if YOU Smell GAS Lighting Instructions Honeywell and SIT Millivolt GAS ValveLighting Instructions To Turn OFF GAS to AppliancePour Fermer LE GAZ QUI Alimente L’APPAREIL Instructions DallumagePosition d’arrêt OFF Front View Lighting Instructions ElectronicWhat to do if YOU Smell GAS To Shut OFFPour Fermer LE GAZ QUI Alimente L’APPAREIL Instructions D’ALLUMAGE ElectronicInstructions D’ALLUMAGE Pour Éteindre L’APPAREILOn page 8- Honeywell Symptom Possible Causes Corrective ActionCheck vent system for obstructions Troubleshooting the Electronic Ignition SystemGAS Controls Electronic Replacement Parts ListGAS Controls SIT Millivolt GAS Controls Honeywell MillivoltDT, DR-500 DR, DR-800 3431725,032M REV. H 11/2004