TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM
Note: Before troubleshooting, be sure that the appliance main line gas
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
| SYMPTOM | POSSIBLE CAUSES | CORRECTIVE ACTION |
|
|
|
|
1. | Burner will not light. | A. Faulty Valve System. | See Below. |
|
|
|
|
|
| B. “OFF/ON” or wall switch | Disconnect the two black wires from the wire nuts. Test switch(s) for |
|
| defective. | continuity with a multimeter. If continuity is not indicated, switch(s) is |
|
|
| defective and must be replaced. |
|
|
| Note: Before replacing “OFF/ON” switch, be sure to check wiring for loose |
|
|
| connections or broken wires and repair as needed. |
|
|
|
|
2. | Burners come “ON” but | A. Burner orifice plugged. | Check main burner orifice(s) for stoppage. Clean or replace. |
| go “OFF.” |
|
|
| B. Obstructed vent system. | Check vent system for obstructions. | |
|
| ||
|
|
|
|
START
•Turn Off Gas Supply
•Assure Valve Switch Is In ON Position
•Disconnect Control Harness
•Set Thermostat To Call For Heat
Insert A | End View Of | |
| Control Harness | |
24 Volt Hot | Connector | |
24 Volt | ||
| ||
| Common |
•Check For Proper Voltage At Control Harness (See Insert A). Voltage Should Be 24V Between Thermostat Or Pressure Switch
And 24V Common And 24V Hot. | 2 |
|
YES
• Plug Control Harness Into Valve. Wait For | |
Internal Check Delay. |
|
• Igniter Warms Up And Glows Red. | |
1 | YES |
|
| CHECK |
NO | • Line Voltage Power | |
• Low Voltage Transformer | ||
|
| • Limit Controller |
|
| • Thermostat |
|
| • Wiring |
|
|
| NO | • With Pilot Burner Cable Connected, Measure | ||
| ||||
| Voltage At Valve HSI Element Output. 24V | |||
|
|
| ||
|
|
| Nominal. (See Insert B) | 2 |
|
|
| 1 | |
|
|
|
|
|
YES
NO
• Replace Valve.
24 Volt
Switched
Check For Damaged Or Missing Terminals In Connector
Insert B
Igniter Terminals
• Turn On Gas Supply. • Pilot Burner Lights. |
YES
•Replace Igniter/Flame Rod Assembly.
YES
| NO | • Check That Pilot Gas Is Flowing. Wait To | NO | • Replace Valve. | |||
| |||||||
|
|
| Assure Plot Gas Tubing Is Purged. Recycle |
|
| ||
|
|
| |||||
|
|
|
|
|
| ||
|
|
| Call For Heat If Necessary. |
|
|
| |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| YES |
|
|
|
•Measure Voltage Between 24V Hot And 24V Common
Leads To Valve Control. Must Measure At Least 19.5 | NO |
|
| ||
VAC With Igniter Powered (See Insert A). To Identify |
|
| • Check Transformer And | ||
|
|
| Line Volt Supply. | ||
Proper Lead, This Check Must Be Done With The |
|
| |||
|
|
| |||
Valve Control Connected And Igniter Powered. |
|
|
| ||
|
|
|
|
|
|
| YES |
|
|
|
•Replace Pilot Assembly.
|
|
|
| • Check That Pilot Flame Makes Good Contact With | |||
|
| NO | Pilot Burner Flame Rod. | ||||
• Main Valve Opens And Main Burner Lights. | • Check For Good Electrical Connection Through The | ||||||
|
|
|
| Pilot Tubing. | |||
|
|
|
| • If Both Of The Above Are Good, Replace Igniter/Flame | |||
| YES |
|
| Rod Assembly. | |||
|
|
|
|
|
|
| |
|
|
|
|
|
| YES | |
|
|
|
|
|
|
| |
• System Is Okay. |
|
|
| • Cycle Thermostat Off And Back On. |
| ||
|
|
|
|
|
|
|
|
1 | Igniter Will Cycle Off And Back On Once During | 2 | When Measured Voltage At Connections, Use | • Main Burner Lights. | NO |
| • Replace Valve. |
| The 90 Second Ignition Trial. All Voltage |
| Care To Assure Terminals Are Not Damaged. |
|
| ||
|
|
| |||||
| Measurements Must Be Taken While The Igniter |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Is Powered. |
|
|
|
|
|
|
17