Weil-McLain RS dimensions Gas control components and sizes, Burner data Natural gas General

Page 3

Burner Specification & Data sheet — Riello Gas Burners

Burner specifications and settings (continued)

Table 2

Burner data — Natural gas — General

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Boiler

Burner

Positive

Standard Burner Model

Standard

Standard

Burner Motor H.P.

 

 

Standard

Model

Input

Pressure In

Designation

Combustion

Control System

3400 RPM

 

 

Motor Voltage

Number

 

Firebox

 

 

Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inches W.C.

On - Off

LHL/MOD

Note 14

On - Off

LHL/MOD

On - Off

LHL/MOD

On - Off

 

LHL/MOD

488R

996

.89

RS28/1

RS28/M

LFL 1.335**

00

LHL/MOD

1/2

 

1/2

120/60/1

 

120/60/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

488

1010

1.00

RS28/1

RS28/M

LFL 1.335**

00

LHL/MOD

1/2

 

1/2

120/60/1

 

120/60/1

 

 

 

 

 

 

 

 

 

 

 

 

 

588

1357

.89

RS38/1

RS38/M

LFL 1.335**

00

LHL/MOD

1/2

1/2 OR 3/4

120/60/1

 

120/60/1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

688

1703

.72

RS50/M

LFL 1.335**

LHL/MOD

 

3/4

 

120/60/1 or 3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

788

2049

.65

RS50/M

LFL 1.335**

LHL/MOD

 

3/4

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

888

2396

.85

RS70/M

LFL 1.335**

LHL/MOD

1

1/2

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

988R

2482

.80

RS70/M

LFL 1.335**

LHL/MOD

1

1/2

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

988

2713

.80

RS70/M

LFL 1.335**

LHL/MOD

1

1/2

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1088R

2887

.82

RS70/M

LFL 1.335**

LHL/MOD

1

1/2

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1088

3103

.82

RS100/M

LFL 1.335**

LHL/MOD

2

1/2

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1188

3392

.82

RS100/M

LFL 1.335**

LHL/MOD

2

1/2

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

1288

3753

.81

RS100/M

LFL 1.335**

LHL/MOD

2 1/2

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

1388

4113

.89

RS100/M

LFL 1.335**

LHL/MOD

2 1/2

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1488

4474

.86

RS130/M

LFL 1.335**

LHL/MOD

 

3

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1588

4763

.86

RS130/M

LFL 1.335**

LHL/MOD

 

3

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1688R

4979

.863

RS130/M

LFL 1.335**

LHL/MOD

 

3

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1688

5124

.83

RS130/M

LFL 1.335**

LHL/MOD

 

3

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1788

5485

.82

RS130/M

LFL 1.335**

LHL/MOD

 

3

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1888

5845

.85

RS190/M

LFL 1.335**

LHL/MOD

 

3

 

3 phase*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*208/60/3, 240/60/3, 480/60/3, 575/60/3, burner motor voltage must be specified

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 3

Gas control components and sizes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Boiler

 

Manual

Low Gas

Gas

Operating

Operating Gas

Safety

Manual

High Gas

Model

 

Hand Valve

Pressure Switch

Pressure Regulator

Gas Valve

Valve (with Proof Of

Gas Valve

Checking Gas Valve

Pressure Switch

Number

 

 

 

 

 

Closure)

 

 

 

 

Inches

 

Inches

Inches

Inches

Inches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

488R – 688

 

1 1/2

Standard

1 1/2

1 1/2

Optional

1 1/2

1 1/2

Standard

 

 

 

 

 

 

 

 

 

 

788 – 1188

 

2

Standard

2

2

Optional

2

2

Standard

 

 

 

 

 

 

 

 

 

 

 

1288

– 1688R

 

2 1/2

Standard

2 1/2

2 1/2

Optional

2 1/2

2 1/2

Standard

 

 

 

 

 

 

 

 

 

 

 

1688

– 1888

 

3

Standard

3

3

Optional

3

3

Standard

 

 

 

 

 

 

 

 

 

 

 

Part No. 550-142-025/0508

3

Image 3
Contents Burner Specification Data Sheet Burner data Natural gas Modulating Burner specifications and settingsBurner data Natural gas General Gas control components and sizesPart No -142-025/0508

RS specifications

Weil-McLain RS, a part of the Weil-McLain family of heating solutions, is known for its reliability and efficiency in residential and commercial heating applications. This product reflects years of engineering expertise and commitment to quality, offering homeowners and business owners an effective solution to heat their spaces.

One of the main features of the Weil-McLain RS is its robust design. Built to withstand the demands of various heating environments, the RS series boasts a cast iron construction that ensures durability and longevity. Cast iron is excellent for retaining heat, enabling the boiler to provide consistent warmth even in cold conditions.

Additionally, the Weil-McLain RS is equipped with an efficient heat exchanger. This component allows for optimal heat transfer, maximizing energy use while minimizing wastage. The advanced design of the heat exchanger also contributes to the boiler's quick response times and enhances overall heating performance.

The RS series incorporates advanced technologies, including multi-stage firing options. This feature allows for precise control over heating output, adapting to varying heating demands. Such adaptability not only improves comfort but also enhances energy savings, as the system can operate at lower capacities during milder conditions.

User-friendly controls are another hallmark of the Weil-McLain RS. The intuitive interface and programmable settings empower users to easily adjust temperatures according to personal preferences. This level of customization ensures a comfortable living environment while allowing homeowners to manage energy consumption effectively.

Furthermore, the Weil-McLain RS is designed with easy maintenance in mind. Access to critical components is straightforward, and the system is compatible with a range of accessories that can enhance its performance and efficiency. For instance, optional components can include water heating capabilities, making the RS versatile for both space heating and domestic hot water needs.

Safety is also a priority in the design of the Weil-McLain RS. The boiler includes multiple safety features, such as pressure relief valves and safety shutoff controls, to ensure secure operation.

Overall, the Weil-McLain RS stands out in the market for its combination of reliability, efficiency, and user-friendly design. Whether used in a residential or commercial setting, it delivers performance you can depend on, making it an excellent choice for anyone seeking an effective heating solution.