Trane manual Table P-3 Size 21 Q-Fan

Page 26

 

 

 

 

 

 

 

 

 

Performance

 

 

 

Q Fan and

 

 

 

 

 

 

 

 

 

 

 

 

 

Data

 

 

 

 

 

 

 

 

Super Q II

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Size 21

 

 

 

 

 

Fan Size 21”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure Class Limits

 

 

 

 

 

 

 

Minimum Fan RPM (Without VFRB Option)

Wheel Dia.

21.5 inches

 

546 mm

 

 

 

 

Class

 

Maximum RPM

 

 

 

 

Motor

 

Minimum Fan RPM

Inlet Area

3.31 square feet

0.308 m2

 

 

 

 

 

I

 

 

2070

 

 

 

 

1800 RPM

 

380

 

 

 

Outlet Area

2.88 square feet

0.268 m2

 

 

 

 

 

II

 

 

 

2780

 

 

 

 

1200 RPM

 

253

 

 

 

Tip Speed

5.63 x RPM

 

1.716

 

 

 

 

 

 

III

 

 

 

3740

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ft./minute

 

m/minute

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table P-3 — Size 21 Q-Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

Out-

 

 

 

 

 

 

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

 

 

 

 

Std.

let

1/4

3/8

1/2

 

 

5/8

3/4

 

 

1”

 

 

1 1/4

 

1 1/2

1 3/4

2”

Air

Vel.

RPM

BHP

RPM BHP

RPM

BHP

 

 

RPM

BHP

RPM

BHP

 

 

RPM

BHP

RPM

BHP

 

RPM

BHP

RPM

BHP

RPM

BHP

 

2600

902

810

0.20

859

0.25

908

0.31

957

0.38

1001

0.44

1096

0.58

1197

0.74

 

 

 

 

 

 

 

 

2800

972

859

0.23

903

0.29

949

0.35

995

0.42

1039

0.48

1121

0.62

1214

0.79

1308

0.96

 

 

 

 

 

3000

1041

909

0.26

949

0.33

991

0.39

1034

0.46

1077

0.53

1155

0.67

1236

0.83

1323

1.02

1411

1.20

 

 

 

3200

1111

959

0.30

996

0.37

1035

0.44

1075

0.51

1116

0.58

1194

0.74

1265

0.89

1344

1.07

1426

1.27

1507

1.46

 

3400

1180

1011

0.35

1045

0.41

1081

0.48

1118

0.56

1156

0.64

1231

0.80

1302

0.96

1369

1.13

1445

1.34

1523

1.53

 

3600

1250

1062

0.40

1094

0.47

1128

0.54

1163

0.61

1198

0.70

1270

0.86

1339

1.04

1401

1.21

1469

1.40

1541

1.62

 

3800

1319

1115

0.45

1145

0.52

1176

0.60

1208

0.68

1242

0.76

1309

0.93

1376

1.11

1440

1.30

1499

1.48

1564

1.69

 

4000

1388

1167

0.51

1196

0.59

1225

0.66

1255

0.74

1286

0.83

1350

1.01

1415

1.20

1477

1.39

1537

1.58

1592

1.78

 

4200

1458

1220

0.58

1247

0.65

1274

0.73

1303

0.82

1332

0.90

1393

1.09

1454

1.28

1515

1.48

1573

1.68

1626

1.88

 

4400

1527

1273

0.65

1299

0.73

1325

0.81

1352

0.90

1379

0.99

1436

1.17

1495

1.37

1553

1.58

1610

1.79

1665

2.01

 

4600

1597

1327

0.73

1351

0.81

1376

0.89

1401

0.98

1427

1.07

1481

1.27

1536

1.47

1593

1.69

1648

1.91

1702

2.12

 

4800

1666

1380

0.81

1403

0.90

1427

0.98

1451

1.07

1476

1.17

1527

1.37

1580

1.58

1633

1.80

1687

2.02

1739

2.25

 

5000

1736

1434

0.90

1456

0.99

1479

1.08

1502

1.17

1525

1.27

1573

1.47

1624

1.69

1675

1.91

1727

2.15

1778

2.38

 

5200

1805

1488

1.00

1509

1.09

1531

1.18

1553

1.28

1575

1.38

1621

1.59

1669

1.80

1718

2.03

1767

2.27

1817

2.52

 

5400

1875

1542

1.11

1562

1.20

1583

1.30

1604

1.39

1625

1.50

1669

1.71

1715

1.93

1762

2.16

1809

2.41

1857

2.66

 

5600

1944

1596

1.22

1616

1.32

1636

1.41

1656

1.52

1676

1.62

1718

1.84

1761

2.06

1806

2.30

1852

2.55

1898

2.81

 

5800

2013

1651

1.34

1669

1.44

1688

1.54

1708

1.65

1727

1.75

1768

1.97

1809

2.21

1852

2.45

1895

2.70

1940

296

 

6000

2083

1705

1.47

1723

1.57

1741

1.68

1760

1.78

1779

1.89

1817

2.12

1857

2.36

1898

2.60

1940

2.86

1982

3.13

 

6200

2152

1759

1.61

1777

1.71

1795

1.82

1813

1.93

1831

2.04

1868

2.27

1906

2.52

1945

2.77

1986

3.03

2026

3.30

 

6400

2222

1814

1.76

1831

1.86

1848

1.97

1865

2.09

1883

2.20

1919

2.44

1955

2.68

1993

2.94

2031

3.21

2071

3.48

 

6600

2291

1869

1.91

1885

2.02

1902

2.14

1918

2.25

1935

2.37

1970

2.61

2005

2.86

2041

3.12

2078

3.39

2116

3.67

 

6800

2361

1923

2.08

1939

2.19

1955

2.31

1971

2.43

1988

2.55

2021

2.79

2055

3.05

 

2090

3.32

2125

3.59

2162

3.87

 

7000

2430

1978

2.25

1993

2.37

2009

2.49

2025

2.61

2041

2.73

 

 

2073

2.99

2106

3.25

 

2139

3.52

2173

3.80

2208

4.09

 

7200

2500

2033

2.44

2048

2.56

2063

2.68

 

 

2078

2.80

2093

2.93

 

 

2125

3.19

2156

3.45

2189

3.73

2222

4.01

2256

4.31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

Out-

 

 

 

 

 

 

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

 

 

 

 

Std.

let

2 1/4

2 1/2

3”

 

 

 

 

3 1/2

4”

 

 

 

4 1/2

 

 

5”

 

5 1/2

6”

 

6 1/2

Air

Vel.

RPM

BHP

RPM BHP

RPM

BHP

 

 

RPM

BHP

RPM

BHP

 

 

RPM

BHP

RPM

BHP

 

RPM

BHP

RPM

BHP

RPM

BHP

 

3600

1250

1615

1.83

1687

2.06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3800

1319

1633

1.92

1703

2.14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4000

1388

1656

2.01

1721

2.25

1852

2.73

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4200

1458

1682

2.10

1743

2.35

1868

2.85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4400

1527

1715

2.21

1769

2.44

1887

2.97

2007

3.49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4600

1597

1754

2.35

1801

2.56

1910

3.08

2023

3.64

2137

4.19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4800

1666

1791

2.48

1840

2.72

1935

3.19

2043

3.77

2153

4.33

 

2261

4.94

 

 

 

 

 

 

 

 

 

 

 

5000

1736

1828

2.62

1877

2.86

1966

3.34

2067

3.91

2170

4.51

 

2276

5.09

 

 

 

 

 

 

 

 

 

 

 

5200

1805

1866

2.77

1914

3.01

2001

3.50

 

2092

4.04

2192

4.66

 

2292

5.29

2394

5.90

 

 

 

 

 

 

 

 

5400

1875

1904

2.92

1951

3.17

2042

3.69

 

2124

4.20

2215

4.80

 

2312

5.46

2410

6.09

 

2507

6.76

 

 

 

 

 

5600

1944

1944

3.07

1989

3.34

2078

3.87

 

 

2158

4.39

2243

4.97

 

2335

5.63

2428

6.31

 

2522

6.96

2615

7.66

 

 

 

5800

2013

1984

3.23

2029

3.51

2116

4.06

 

 

2199

4.62

2275

5.16

 

2359

5.79

2449

6.50

 

2539

7.20

2631

7.87

2720

8.61

 

6000

2083

2026

3.40

2069

3.68

2153

4.26

 

 

2236

4.83

2310

5.38

 

2388

5.99

2471

6.66

 

2559

7.41

2646

8.14

2735

8.83

 

6200

2152

2067

3.58

2109

3.87

2192

4.46

 

 

2273

5.04

2351

5.65

 

2421

6.22

2499

6.88

 

2582

7.62

2666

8.37

2751

9.12

 

6400

2222

2111

3.77

2151

4.06

2231

4.66

 

 

2311

5.26

2388

5.88

 

2461

6.51

2529

7.11

 

2606

7.81

2688

8.60

2769

9.37

 

6600

2291

2154

3.96

2193

4.26

2272

4.87

 

 

2349

5.50

2425

6.12

 

2498

6.77

2563

7.37

 

2635

8.05

2710

8.79

2791

9.62

 

6800

2361

2199

4.17

2236

4.47

2312

5.09

 

 

2388

5.74

2462

6.37

 

2535

7.03

2604

7.70

 

2667

8.33

2738

9.05

2815

9.87

 

7000

2430

2244

4.38

2281

4.69

2354

5.32

 

 

2428

5.98

2500

6.65

 

2572

7.31

2641

7.99

 

2702

8.62

2769

9.33

2839

10.09

 

7200

2500

2290

4.61

2325

4.92

2396

5.56

 

 

2468

6.23

2539

6.91

 

2609

7.59

2678

8.29

 

2744

8.99

2803

9.64

2869

10.39

 

7400

2569

2336

4.85

2371

5.16

2439

5.81

 

 

2509

6.49

2579

7.19

 

2647

7.90

2715

8.59

 

2780

9.31

2844

10.04

2901

10.71

 

7600

2638

2384

5.09

2416

5.41

2483

6.07

 

 

2550

6.76

2619

7.47

 

2686

8.20

2752

8.90

 

2817

9.64

2880

10.38

2936

11.06

 

7800

2708

2431

5.35

2463

5.67

2528

6.34

 

 

2593

7.04

2659

7.76

 

2725

8.50

2790

9.25

 

2855

9.98

2917

10.74

2978

11.50

 

8000

2777

2479

5.62

2510

5.95

2573

6.63

 

 

2636

7.33

2701

8.06

 

2765

8.82

2829

9.58

 

2892

10.32

2954

11.10

3014

11.88

 

8200

2847

2528

5.90

2558

6.24

2619

6.92

 

 

2680

7.64

2742

8.38

 

2806

9.14

2868

9.92

 

2930

10.71

2991

11.47

3051

12.26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

Out-

 

 

 

 

 

 

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

 

 

 

 

Std.

let

7”

 

7 1/2

8”

 

 

 

 

8 1/2

9”

 

 

 

9 1/2

 

 

10”

 

10 1/2

11”

11 1/2

 

 

Air

Vel.

RPM

BHP

RPM BHP

RPM

BHP

 

 

RPM

BHP

RPM

BHP

 

 

RPM

BHP

RPM

BHP

 

RPM

BHP

RPM

BHP

RPM

BHP

 

6000

2083

2821

9.60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6200

2152

2836

9.84

2919

10.64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6400

2222

2851

10.15

2934

10.89

3015

11.71

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6600

2291

2870

10.42

2951

11.16

3030

11.98

 

 

3108

12.83

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6800

2361

2891

10.68

2967

11.51

3046

12.27

 

 

3123

13.11

3199

13.99

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7000

2430

2914

10.95

2988

11.79

3063

12.64

 

 

3139

13.43

3214

14.29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7200

2500

2937

11.18

3011

12.08

3083

12.95

 

 

3155

13.82

3230

14.62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7400

2569

2966

11.49

3033

12.32

3105

13.25

 

 

3175

14.15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7600

2638

2997

11.83

3061

12.64

3127

13.50

 

 

3197

14.47

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7800

2708

3031

12.19

3092

12.99

3154

13.84

 

 

3222

14.80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8000

2777

3073

12.66

3125

13.37

3184

14.21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8200

2847

3110

13.07

3160

13.78

3217

14.60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8400

2916

3146

13.48

3203

14.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8600

2986

3183

13.90

3239

14.74

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8800

3055

3220

14.32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9000

3125

3258

14.76

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar). Performance shown is for installationType B: free inlet, ducted outlet.

 

 

 

 

 

Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances in the airstream.

 

 

 

 

 

 

 

 

When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent.

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan tables cover part of fan operating range; fan curves show full operating range.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 26
Contents FAN-DS-2 August Model Q Fans Sizes 16 through Super Q II FansFeatures and Benefits Contents Features Benefits Trane Model Q fans require up toSuper Q II Fan Variable Air Volume CompatibleSuper Q II Accessories Super QTrane Plus Duct Silencer Plus SilencerStatic regain Airflow Aerodynamic Air Path This provides smooth, spiral-free dischargeFeatures Benefits Saving Valuable Equipment Room Space Draw-Thru Supply Application Small CapacityDraw-Thru Supply Application Large Capacity Figure F-5Table F-1 Total Installed Cost Comparison Features Benefits Reduce Installed Cost By UpTo 20 PercentLower Installation Costs First Cost ComparisonsValid Select Prod Able Prod. able Cat Description Model Number DescriptionValid Select Prod Able Cat Description System System Curve Application ConsiderationsAbbreviations Performance Data Determination Fan Performance CurvesUnducted Plenum Inlet Unducted Outlet Table A-1 Q Fan/Super Q II Fan Installation Kt CorrectionsFan Option Kt Corrections Ducted Inlet Ducted OutletSuper Q II Fan Modulation AC Inverter Capacity Control Figure A-5 VAV System Modulation CurveFigure A-6 Inlet Vane Performance Table A-3 Maximum Torque For Operation Of InletVanes Motor and Drive SelectionParallel Fan Operation Table A-4 Parallel OperationRecommended Super Q II NC40 Plenum Configuration Operating Cost/EfficiencyTable A-5 Inlet Vane Sound Data Fan Sound DataTrane Acoustics Program Table S-2 Long Plus Silencer Attenuation 2D Length Selection ProcedureTable S-1 Short Plus Silencer Attenuation 1D Length Fan Size PerformanceData Minimum Fan RPM Without Vfrb OptionPerformance Fan Data Super Q Size Minimum and Maximum Motor HP RangesTable P-2 Size 19 Q Fan Performance Fan Data Super Q Size Table P-3 Size 21 Q-Fan Performance Fan Data Super Q Size Table P-4 Size 24 Q-Fan Arrangement 15-30 Table P-5 Size 27 Q-Fan Arrangement Table P-6 Size 30 Q-Fan Performance Fan Data Super Q Size Table P-7 Size 33 Q-Fan Performance Fan Data Super Q Size Table P-8 Size 36 Q-Fan Performance Fan Data Super Q Size Table P-9 Size 40 Q Fan Performance Fan Data Super Q Size Table P-10 Size 44 Q-Fan Performance Fan Data Super Q Size Minimum Fan RPM Without Vfrb Option Fan Table P-12 Size 54 Q-Fan Fan Table P-13 Size 60 Q-Fan Fan Arrangement Dimensional Data WeightsArrangement 9 Dimensions Out Arrangement 1 Dimensions Out Arrangement1Arrangement 9 Dimensions Dimensional Figure D-1 Q Fan Inlet Vanes Table D-1 Inlet Vane DimensionsFigure D-3 Super Q II 16-44 Sizes Table D-3 Table D-5 Long Outlet Plus Silencer Mechanical Specifications Inlet Bellmouth Q, SQ2 Adjustable Inlet VanesInlet Screen Q, SQ2 Inlet Flange QFAN-DS-2

Fan specifications

Trane is a well-known name in the heating, ventilation, and air conditioning (HVAC) industry, and one of their standout products is the Trane Fan. Designed to provide efficient and effective airflow, the Trane Fan is a versatile solution suited for both residential and commercial applications.

One of the main features of the Trane Fan is its Energy Efficiency. With increasing energy costs, having a fan that operates efficiently is crucial. Trane fans are designed with advanced motor technology that enhances performance while reducing energy consumption. This not only helps lower utility bills but also contributes to a more sustainable environment.

The Variable Speed Technology is another notable characteristic. Trane fans come equipped with variable speed motors that adjust the airflow according to the specific needs of a space. This adaptability means that the fan can run at lower speeds, providing quiet operation while maintaining comfort levels, and ramping up power when needed for more intense cooling or ventilation.

Durability and robustness are core attributes of Trane fans. Constructed from high-quality materials, these fans are built to withstand harsh conditions and continue to function optimally over time. This longevity is essential for commercial settings where reliability is paramount.

Additionally, Trane delivers innovative sound-reduction technologies within their fan designs. Special engineering ensures that these units operate quietly, making them ideal for environments such as offices, schools, and homes where noise can be a distraction.

Another significant aspect is Smart Technology Integration. Trane fans are compatible with various smart home systems, allowing users to control their systems remotely. This feature enhances convenience, enabling homeowners and facility managers to monitor and adjust air quality effortlessly.

In terms of ease of installation, Trane Fans are designed with user-friendly features that facilitate quicker setup and less hassle. Their modular designs allow for flexibility in installation across various applications.

In summary, the Trane Fan stands out due to its energy efficiency, variable speed technology, durability, sound-reduction capabilities, smart technology integration, and ease of installation. These characteristics make Trane fans a reliable choice for enhancing indoor air quality across diverse environments.