Trane Fan manual Dimensional Data Weights, Arrangement 9 Dimensions Out

Page 48

Dimensional

Data and

Weights

Roughing-In Dimensions

Arrangement 9

Arrangement 9 Dimensions

 

 

In

Out

 

 

 

Drive

Unit

 

 

 

 

H

Shaft

Net Wt.

Size

 

A

B

L

W

Max.

Dia.

Lbs.

16

Class I

19 3/8

17 7/8

28 3/8

23 5/8

45

15/16

115

16

Class II

19 3/8

17 7/8

28 3/8

23 5/8

45

15/16

115

16

Class III

19 3/8

17 7/8

28 3/8

23 5/8

45

1 3/16

120

19

Class I

21 7/8

20 1/2

28 7/8

26 1/8

48 1/4

15/16

135

19

Class II

21 7/8

20 1/2

28 7/8

26 1/8

48 1/4

15/16

135

19

Class III

21 7/8

20 1/2

28 7/8

26 1/8

48 1/4

1 3/16

140

21

Class I

24 5/8

23 1/8

32 3/4

29

51 3/8

15/16

175

21

Class II

24 5/8

23 1/8

32 3/4

29

51 3/8

1 3/16

180

21

Class III

24 5/8

23 1/8

32 3/4

29

51 3/8

1 3/16

185

24

Class I

28 1/8

26 3/8

35 3/8

32 7/8

55 1/4

1 3/16

215

24

Class II

28 1/8

26 3/8

35 3/8

32 7/8

55 1/4

1 3/16

220

24

Class III

28 1/8

26 3/8

35 3/8

32 7/8

55 1/4

1 11/16

225

27

Class I

30 7/8

29

38

35 3/4

58 1/8

1 3/16

275

27

Class II

30 7/8

29

38

35 3/4

58 1/8

1 7/16

290

27

Class III

30 7/8

29

38

35 3/4

58 1/8

1 15/16

305

30

Class I

34 3/8

32 1/4

41 1/8

39 1/8

61 5/8

1 3/16

350

30

Class II

34 3/8

32 1/4

41 1/8

39 1/8

61 5/8

1 7/16

360

30

Class III

34 3/8

32 1/4

41 1/8

39 1/8

61 5/8

1 15/16

375

33

Class I

37 3/4

35 1/2

45

42 5/8

65 1/8

1 3/16

440

33

Class II

37 3/4

35 1/2

45

42 5/8

65 1/8

1 7/16

450

33

Class III

37 3/4

35 1/2

45

42 5/8

65 1/8

2 3/16

485

36

Class I

41 3/4

39 1/4

49 1/2

47 5/8

69 5/8

1 7/16

575

36

Class II

41 3/4

39 1/4

49 1/2

47 5/8

69 5/8

1 11/16

580

36

Class III

41 3/4

39 1/4

49 1/2

47 5/8

69 5/8

2 7/16

630

40

Class I

46

43 1/4

53 3/4

51 7/8

77

1 7/16

710

40

Class II

46

43 1/4

53 3/4

51 7/8

77

1 11/16

720

40

Class III

46

43 1/4

53 3/4

51 7/8

77

2 15/16

800

44

Class I

50 7/8

47 3/4

60 5/8

56 3/4

82

1 11/16

830

44

Class II

50 7/8

47 3/4

60 5/8

56 3/4

82

1 15/16

850

44

Class III

50 7/8

47 3/4

60 5/8

56 3/4

82

3 7/16

950

Approximate weights are without motor and drive.

Motor position should be determined from the outlet side.

48

Image 48
Contents FAN-DS-2 August Model Q Fans Sizes 16 through Super Q II FansFeatures and Benefits Contents Features Benefits Trane Model Q fans require up toVariable Air Volume Compatible Super Q II AccessoriesSuper Q II Fan Super QTrane Plus Duct Silencer Plus SilencerStatic regain Airflow Aerodynamic Air Path This provides smooth, spiral-free dischargeFeatures Benefits Saving Valuable Equipment Room Space Draw-Thru Supply Application Small CapacityDraw-Thru Supply Application Large Capacity Figure F-5Features Benefits Reduce Installed Cost By UpTo 20 Percent Lower Installation CostsTable F-1 Total Installed Cost Comparison First Cost ComparisonsModel Number Description Valid Select Prod Able Cat DescriptionValid Select Prod Able Prod. able Cat Description Application Considerations AbbreviationsSystem System Curve Performance Data Determination Fan Performance CurvesTable A-1 Q Fan/Super Q II Fan Installation Kt Corrections Fan Option Kt CorrectionsUnducted Plenum Inlet Unducted Outlet Ducted Inlet Ducted OutletSuper Q II Fan Modulation AC Inverter Capacity Control Figure A-5 VAV System Modulation CurveFigure A-6 Inlet Vane Performance Motor and Drive Selection Parallel Fan OperationTable A-3 Maximum Torque For Operation Of InletVanes Table A-4 Parallel OperationRecommended Super Q II NC40 Plenum Configuration Operating Cost/EfficiencyFan Sound Data Trane Acoustics ProgramTable A-5 Inlet Vane Sound Data Selection Procedure Table S-1 Short Plus Silencer Attenuation 1D LengthTable S-2 Long Plus Silencer Attenuation 2D Length Performance DataFan Size Minimum Fan RPM Without Vfrb OptionPerformance Fan Data Super Q Size Minimum and Maximum Motor HP RangesTable P-2 Size 19 Q Fan Performance Fan Data Super Q Size Table P-3 Size 21 Q-Fan Performance Fan Data Super Q Size Table P-4 Size 24 Q-Fan Arrangement 15-30 Table P-5 Size 27 Q-Fan Arrangement Table P-6 Size 30 Q-Fan Performance Fan Data Super Q Size Table P-7 Size 33 Q-Fan Performance Fan Data Super Q Size Table P-8 Size 36 Q-Fan Performance Fan Data Super Q Size Table P-9 Size 40 Q Fan Performance Fan Data Super Q Size Table P-10 Size 44 Q-Fan Performance Fan Data Super Q Size Minimum Fan RPM Without Vfrb Option Fan Table P-12 Size 54 Q-Fan Fan Table P-13 Size 60 Q-Fan Fan Dimensional Data Weights Arrangement 9 Dimensions OutArrangement Arrangement 1 Dimensions Out Arrangement1Arrangement 9 Dimensions Dimensional Figure D-1 Q Fan Inlet Vanes Table D-1 Inlet Vane DimensionsFigure D-3 Super Q II 16-44 Sizes Table D-3 Table D-5 Long Outlet Plus Silencer Mechanical Specifications Adjustable Inlet Vanes Inlet Screen Q, SQ2Inlet Bellmouth Q, SQ2 Inlet Flange QFAN-DS-2

Fan specifications

Trane is a well-known name in the heating, ventilation, and air conditioning (HVAC) industry, and one of their standout products is the Trane Fan. Designed to provide efficient and effective airflow, the Trane Fan is a versatile solution suited for both residential and commercial applications.

One of the main features of the Trane Fan is its Energy Efficiency. With increasing energy costs, having a fan that operates efficiently is crucial. Trane fans are designed with advanced motor technology that enhances performance while reducing energy consumption. This not only helps lower utility bills but also contributes to a more sustainable environment.

The Variable Speed Technology is another notable characteristic. Trane fans come equipped with variable speed motors that adjust the airflow according to the specific needs of a space. This adaptability means that the fan can run at lower speeds, providing quiet operation while maintaining comfort levels, and ramping up power when needed for more intense cooling or ventilation.

Durability and robustness are core attributes of Trane fans. Constructed from high-quality materials, these fans are built to withstand harsh conditions and continue to function optimally over time. This longevity is essential for commercial settings where reliability is paramount.

Additionally, Trane delivers innovative sound-reduction technologies within their fan designs. Special engineering ensures that these units operate quietly, making them ideal for environments such as offices, schools, and homes where noise can be a distraction.

Another significant aspect is Smart Technology Integration. Trane fans are compatible with various smart home systems, allowing users to control their systems remotely. This feature enhances convenience, enabling homeowners and facility managers to monitor and adjust air quality effortlessly.

In terms of ease of installation, Trane Fans are designed with user-friendly features that facilitate quicker setup and less hassle. Their modular designs allow for flexibility in installation across various applications.

In summary, the Trane Fan stands out due to its energy efficiency, variable speed technology, durability, sound-reduction capabilities, smart technology integration, and ease of installation. These characteristics make Trane fans a reliable choice for enhancing indoor air quality across diverse environments.