Trane manual Table P-12 Size 54 Q-Fan

Page 44

 

 

 

 

 

 

 

 

 

Performance

 

 

 

 

Q Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data

 

 

 

 

 

 

 

 

Size 54

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Size 54”

 

 

 

 

 

 

Pressure Class Limits

 

 

 

 

 

 

 

Minimum Fan RPM (Without VFRB Option)

Wheel Dia.

54.3 inches

 

1378 mm

 

 

 

Class

 

Maximum RPM

 

 

 

 

 

 

Motor

 

Minimum Fan RPM

 

 

 

 

 

 

 

 

 

 

I

 

 

857

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inlet Area

18.37 square feet

1.707 m2

 

 

 

 

 

 

 

 

 

 

 

 

1800 RPM

 

 

292

 

 

 

 

 

 

 

 

 

 

 

II

 

 

 

1151

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet Area

18.37 square feet

1.707 m2

 

 

 

 

 

 

 

 

 

 

 

 

 

1200 RPM

 

 

195

 

 

 

Tip Speed

14.20 x RPM

 

4.328

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ft./minute

 

m/minute

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table P-12 — Size 54 Q-Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

Out-

 

 

 

 

 

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

Std.

let

1/4

 

3/8

1/2

 

 

 

5/8

3/4

 

 

1”

 

 

 

1 1/4

 

 

1 1/2

 

1 3/4

2”

 

 

Air

Vel.

RPM

BHP

RPM BHP

RPM

BHP

 

RPM

BHP

RPM

BHP

 

RPM

BHP

RPM

BHP

 

 

RPM

BHP

RPM

BHP

RPM

BHP

 

16200

881

323

1.2

344

1.6

365

1.9

387

2.4

410

2.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17600

958

344

1.4

363

1.8

382

2.2

402

2.6

422

3.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19000 1034

365

1.7

383

2.1

401

2.5

419

2.9

437

3.4

475

4.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20400 1110

387

1.9

403

2.3

420

2.8

437

3.2

454

3.7

488

4.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21800 1186

410

2.2

425

2.7

440

3.1

456

3.6

471

4.1

503

5.2

 

536

 

6.3

 

 

 

 

 

 

 

 

 

23200 1262

432

2.6

446

3.0

460

3.5

475

4.0

490

4.5

519

5.6

 

550

 

6.8

582

8.1

 

 

 

 

 

24600 1339

455

3.0

468

3.4

481

3.9

495

4.5

509

5.0

537

6.1

 

565

 

7.3

594

8.6

625

10.0

 

 

 

26000 1415

479

3.4

491

3.9

503

4.4

516

4.9

529

5.5

555

6.6

 

581

 

7.8

608

9.2

636

10.6

666

12.1

 

27400 1491

502

3.8

513

4.3

525

4.9

537

5.4

549

6.0

574

7.2

 

599

 

8.4

624

9.8

650

11.2

677

12.7

 

28800 1567

525

4.3

536

4.9

547

5.4

558

6.0

570

6.6

594

7.9

 

617

 

9.1

641

10.5

665

11.9

690

13.5

 

30200 1643

549

4.9

559

5.5

569

6.0

580

6.6

591

7.2

613

8.6

 

636

 

9.9

658

11.2

681

12.7

705

14.2

 

31600 1720

572

5.5

582

6.1

592

67

602

7.3

612

7.9

633

9.3

 

655

 

10.7

676

12.0

698

13.5

720

15.0

 

33000 1796

596

6.2

605

6.8

615

7.4

624

8.0

634

8.7

654

10.0

 

675

 

11.5

696

12.9

716

14.4

737

15.9

 

34400 1872

620

6.9

629

7.5

638

8.1

647

8.8

656

9.5

675

10.9

 

695

 

12.4

715

13.9

734

15.3

754

16.9

 

35800 1948

644

7.7

652

8.3

661

8.9

669

9.6

678

10.3

696

11.8

 

715

 

13.3

734

14.9

753

16.4

772

17.9

 

37200 2025

668

8.5

676

9.1

684

9.8

692

10.5

701

11.2

718

12.7

 

736

 

14.2

754

15.9

773

17.5

791

19.2

 

38600 2101

691

9.4

699

10.1

707

10.8

715

11.5

723

12.2

740

13.7

 

757

 

15.3

775

17.0

792

18.7

810

20.4

 

40000 2177

715

10.3

723

11.0

731

11.7

738

12.5

746

13.2

762

14.8

 

778

 

16.4

795

18.1

812

19.9

829

21.6

 

41400 2253

739

11.4

747

12.1

754

12.8

761

13.6

769

14.3

784

15.9

 

800

 

17.6

816

19.3

833

21.1

849

22.9

 

42800 2329

763

12.4

770

13.2

778

13.9

785

14.7

792

15.5

807

17.1

 

822

 

18.8

837

20.6

853

22.4

869

24.3

 

44200 2406

788

13.6

794

14.4

801

15.1

808

15.9

815

16.8

829

18.4

 

844

 

20.2

 

 

858

21.9

873

23.8

889

25.7

 

45600 2482

812

14.8

818

15.6

825

16.4

831

17.2

838

18.1

852

19.8

 

866

 

21.5

 

 

880

23.4

894

25.3

909

27.2

 

47000 2558

836

16.1

842

17.0

849

17.8

855

18.6

862

19.5

875

21.2

 

888

 

23.0

 

 

902

24.9

916

26.8

930

28.8

 

48400 2634

860

17.5

866

18.4

872

19.2

879

20.1

885

20.9

898

22.7

 

911

 

24.6

 

 

924

26.5

937

28.4

951

30.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

Out-

 

 

 

 

 

 

 

 

 

 

 

Total Static Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

Std.

let

2 1/4

2 1/2

3”

 

 

 

3 1/2

4”

 

 

4 1/2

 

 

 

5”

 

 

 

5 1/2

 

6”

 

6 1/2

 

Air

Vel.

RPM

BHP

RPM BHP

RPM

BHP

 

RPM

BHP

RPM

BHP

 

RPM

BHP

RPM

BHP

 

 

RPM

BHP

RPM

BHP

RPM

BHP

 

29000 1578

717

15.2

744

16.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30400 1654

730

16.0

755

17.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31800 1731

745

16.8

767

18.5

815

22.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33200 1807

760

17.7

782

19.5

826

23.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34600 1883

777

18.7

797

20.5

838

24.2

 

882

28.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36000 1959

794

19.8

813

21.6

852

25.3

 

893

29.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37400 2035

811

20.9

830

22.7

867

26.5

 

906

30.5

946

34.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38800 2112

830

22.2

847

23.9

883

27.7

 

920

31.8

957

36.1

 

997

40.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40200 2188

849

23.6

865

25.2

900

29.0

 

935

33.2

970

37.5

 

1007

42.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41600 2264

868

25.0

884

26.8

917

30.5

 

950

34.6

985

39.0

 

1019

43.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1056

 

48.3

 

 

 

 

 

 

 

 

 

43000 2340

888

26.4

903

28.3

935

32.0

 

967

36.1

999

40.6

 

1033

45.2

 

1067

 

49.9

 

1103

55.0

 

 

 

 

 

44400 2416

907

27.9

923

29.8

953

33.6

 

984

37.7

1015

42.2

 

1047

46.9

 

1080

 

51.6

 

1113

56.7

 

 

 

 

 

45800 2493

927

29.4

942

31.5

972

35.5

 

1001

39.5

1032

43.9

 

1062

48.6

 

1094

 

53.5

 

1125

58.5

 

 

 

 

 

47200 2569

948

31.1

962

33.1

991

37.3

 

1019

41.3

1048

45.8

 

1078

50.5

 

1108

 

55.4

 

 

 

 

 

 

 

 

 

48600 2645

968

32.7

982

34.9

1010

39.2

 

1038

43.3

1066

47.7

 

1094

52.4

 

1123

 

57.4

 

 

 

 

 

 

 

 

 

50000 2721

988

34.5

1002

36.7

1030

41.1

 

1057

45.5

1084

49.8

 

1111

54.5

 

1139

 

59.5

 

 

 

 

 

 

 

 

 

51400 2798

1010

36.4

1023

38.6

1050

43.1

 

1076

47.7

1102

52.0

 

1129

56.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52800 2874

1031

38.4

1043

40.6

1070

45.2

 

1095

49.9

1121

54.5

 

1146

59.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

54200 2950

1052

40.4

1064

42.7

1090

47.4

 

1115

52.1

1140

56.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55600 3026

1074

42.6

1086

44.8

1110

49.5

 

1135

54.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57000 3102

1096

44.8

1107

47.1

1130

51.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58400 3179

1118

47.1

1129

49.5

1151

54.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

59800 3255

1140

49.5

1151

51.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance based on 0.075 lbs. per cubic foot density (air at 70 F and 29.92 Hg Bar).

Performance shown is for installationType B: free inlet, ducted outlet.

Power rating (BHP) does not include drive losses.

Performance ratings do not include the effects of appurtenances in the airstream.

When inlet vanes are used increase rpm 1 percent and brake horsepower 3 percent.

Fan tables cover part of fan operating range; fan curves show full operating range.

44

Image 44
Contents FAN-DS-2 August Model Q Fans Sizes 16 through Super Q II FansFeatures and Benefits Contents Features Benefits Trane Model Q fans require up toVariable Air Volume Compatible Super Q II AccessoriesSuper Q II Fan Super QTrane Plus Duct Silencer Plus SilencerStatic regain Airflow Aerodynamic Air Path This provides smooth, spiral-free dischargeFeatures Benefits Saving Valuable Equipment Room Space Draw-Thru Supply Application Small CapacityDraw-Thru Supply Application Large Capacity Figure F-5Features Benefits Reduce Installed Cost By UpTo 20 Percent Lower Installation CostsTable F-1 Total Installed Cost Comparison First Cost ComparisonsValid Select Prod Able Prod. able Cat Description Model Number DescriptionValid Select Prod Able Cat Description System System Curve Application ConsiderationsAbbreviations Performance Data Determination Fan Performance CurvesTable A-1 Q Fan/Super Q II Fan Installation Kt Corrections Fan Option Kt CorrectionsUnducted Plenum Inlet Unducted Outlet Ducted Inlet Ducted OutletSuper Q II Fan Modulation AC Inverter Capacity Control Figure A-5 VAV System Modulation CurveFigure A-6 Inlet Vane Performance Motor and Drive Selection Parallel Fan OperationTable A-3 Maximum Torque For Operation Of InletVanes Table A-4 Parallel OperationRecommended Super Q II NC40 Plenum Configuration Operating Cost/EfficiencyTable A-5 Inlet Vane Sound Data Fan Sound DataTrane Acoustics Program Table S-2 Long Plus Silencer Attenuation 2D Length Selection ProcedureTable S-1 Short Plus Silencer Attenuation 1D Length Performance DataFan Size Minimum Fan RPM Without Vfrb OptionPerformance Fan Data Super Q Size Minimum and Maximum Motor HP RangesTable P-2 Size 19 Q Fan Performance Fan Data Super Q Size Table P-3 Size 21 Q-Fan Performance Fan Data Super Q Size Table P-4 Size 24 Q-Fan Arrangement 15-30 Table P-5 Size 27 Q-Fan Arrangement Table P-6 Size 30 Q-Fan Performance Fan Data Super Q Size Table P-7 Size 33 Q-Fan Performance Fan Data Super Q Size Table P-8 Size 36 Q-Fan Performance Fan Data Super Q Size Table P-9 Size 40 Q Fan Performance Fan Data Super Q Size Table P-10 Size 44 Q-Fan Performance Fan Data Super Q Size Minimum Fan RPM Without Vfrb Option Fan Table P-12 Size 54 Q-Fan Fan Table P-13 Size 60 Q-Fan Fan Arrangement Dimensional Data WeightsArrangement 9 Dimensions Out Arrangement 1 Dimensions Out Arrangement1Arrangement 9 Dimensions Dimensional Figure D-1 Q Fan Inlet Vanes Table D-1 Inlet Vane DimensionsFigure D-3 Super Q II 16-44 Sizes Table D-3 Table D-5 Long Outlet Plus Silencer Mechanical Specifications Adjustable Inlet Vanes Inlet Screen Q, SQ2Inlet Bellmouth Q, SQ2 Inlet Flange QFAN-DS-2

Fan specifications

Trane is a well-known name in the heating, ventilation, and air conditioning (HVAC) industry, and one of their standout products is the Trane Fan. Designed to provide efficient and effective airflow, the Trane Fan is a versatile solution suited for both residential and commercial applications.

One of the main features of the Trane Fan is its Energy Efficiency. With increasing energy costs, having a fan that operates efficiently is crucial. Trane fans are designed with advanced motor technology that enhances performance while reducing energy consumption. This not only helps lower utility bills but also contributes to a more sustainable environment.

The Variable Speed Technology is another notable characteristic. Trane fans come equipped with variable speed motors that adjust the airflow according to the specific needs of a space. This adaptability means that the fan can run at lower speeds, providing quiet operation while maintaining comfort levels, and ramping up power when needed for more intense cooling or ventilation.

Durability and robustness are core attributes of Trane fans. Constructed from high-quality materials, these fans are built to withstand harsh conditions and continue to function optimally over time. This longevity is essential for commercial settings where reliability is paramount.

Additionally, Trane delivers innovative sound-reduction technologies within their fan designs. Special engineering ensures that these units operate quietly, making them ideal for environments such as offices, schools, and homes where noise can be a distraction.

Another significant aspect is Smart Technology Integration. Trane fans are compatible with various smart home systems, allowing users to control their systems remotely. This feature enhances convenience, enabling homeowners and facility managers to monitor and adjust air quality effortlessly.

In terms of ease of installation, Trane Fans are designed with user-friendly features that facilitate quicker setup and less hassle. Their modular designs allow for flexibility in installation across various applications.

In summary, the Trane Fan stands out due to its energy efficiency, variable speed technology, durability, sound-reduction capabilities, smart technology integration, and ease of installation. These characteristics make Trane fans a reliable choice for enhancing indoor air quality across diverse environments.