Trane Fan manual Contents

Page 3

Contents

Q Fan Accessories

Inlet flange — for simplified, rigid connection of ductwork to inlet end of fan

Inlet screen — safety accessory mounted to fan inlet. Heavy, plated steel wire

Note: inlet screen and inlet flange are mutually exclusive.

Inlet vanes — mechanically modulate fan capacity

Inlet bellmouth — used with unducted or plenum applications. Improves air flow and reduces noise.

Inlet silencer (long or short) — flex connected to Q fan

Outlet flange — for simplified, rigid connection of ductwork to outlet end of fan

Outlet screen — safety accessory mounted to fan outlet. Heavy, plated steel wire

Note: outlet screen and outlet flange are mutually exclusive.

Outlet duct diffuser (equalizer) — makes fan outlet diameter equal to inlet diameter

Outlet flow stabilization screen — small mesh outlet screen. Helps offset effect of poor outlet airflow conditions

Outlet silencer (short or long) — flex connected to Q fan

Vertical mounting legs — used with arrangement 9 for vertical discharge floor and ceiling mounted

Isolators — to eliminate vibrations for

floor, ceiling and vertical installations

 

Special coatings — to protect against

 

alkyds, acids and corrosive

 

environments

 

Access door — available on sizes 49, 54

 

and 60 for easier service

 

Drain — recommended to drain off the

 

condensate where moisture-laden air is

 

exhausted

 

Copper grease lines — plastic lines are

 

standard

 

Double acoustic enhancement —

 

insulation and perforated sheet metal

 

to attenuate radiated sound

 

Fan insulation — self-adhesive foam,

 

applied on the outside of the fan shell

 

to protect against moisture

 

Variable frequency inverter balancing

 

and reinforcement (frequency inverter

 

by others). This option requires

 

constant pitch drives.

Model Q Fan — Arrangement 9

Features and Benefits

2

 

 

Model Number Description

12

 

 

Application Considerations

13

 

 

Selection Procedure

21

 

 

Performance Data

22

 

 

Dimensional Data and Weights

48

 

 

Mechanical Specifications

54

 

 

3

Image 3
Contents August Model Q Fans Sizes 16 through Super Q II Fans FAN-DS-2Features and Benefits Contents Trane Model Q fans require up to Features BenefitsSuper Q Variable Air Volume CompatibleSuper Q II Accessories Super Q II FanPlus Silencer Trane Plus Duct SilencerStatic regain Airflow This provides smooth, spiral-free discharge Aerodynamic Air PathDraw-Thru Supply Application Small Capacity Features Benefits Saving Valuable Equipment Room SpaceFigure F-5 Draw-Thru Supply Application Large CapacityFirst Cost Comparisons Features Benefits Reduce Installed Cost By UpTo 20 PercentLower Installation Costs Table F-1 Total Installed Cost ComparisonModel Number Description Valid Select Prod Able Cat DescriptionValid Select Prod Able Prod. able Cat Description Application Considerations AbbreviationsSystem System Curve Fan Performance Curves Performance Data DeterminationDucted Inlet Ducted Outlet Table A-1 Q Fan/Super Q II Fan Installation Kt CorrectionsFan Option Kt Corrections Unducted Plenum Inlet Unducted OutletFigure A-5 VAV System Modulation Curve Super Q II Fan Modulation AC Inverter Capacity ControlFigure A-6 Inlet Vane Performance Table A-4 Parallel Operation Motor and Drive SelectionParallel Fan Operation Table A-3 Maximum Torque For Operation Of InletVanesOperating Cost/Efficiency Recommended Super Q II NC40 Plenum ConfigurationFan Sound Data Trane Acoustics ProgramTable A-5 Inlet Vane Sound Data Selection Procedure Table S-1 Short Plus Silencer Attenuation 1D LengthTable S-2 Long Plus Silencer Attenuation 2D Length Minimum Fan RPM Without Vfrb Option PerformanceData Fan SizeMinimum and Maximum Motor HP Ranges Performance Fan Data Super Q SizeTable P-2 Size 19 Q Fan Performance Fan Data Super Q Size Table P-3 Size 21 Q-Fan Performance Fan Data Super Q Size Table P-4 Size 24 Q-Fan Arrangement 15-30 Table P-5 Size 27 Q-Fan Arrangement Table P-6 Size 30 Q-Fan Performance Fan Data Super Q Size Table P-7 Size 33 Q-Fan Performance Fan Data Super Q Size Table P-8 Size 36 Q-Fan Performance Fan Data Super Q Size Table P-9 Size 40 Q Fan Performance Fan Data Super Q Size Table P-10 Size 44 Q-Fan Performance Fan Data Super Q Size Minimum Fan RPM Without Vfrb Option Fan Table P-12 Size 54 Q-Fan Fan Table P-13 Size 60 Q-Fan Fan Dimensional Data Weights Arrangement 9 Dimensions OutArrangement Arrangement1 Arrangement 1 Dimensions OutArrangement 9 Dimensions Figure D-1 Q Fan Inlet Vanes Table D-1 Inlet Vane Dimensions DimensionalFigure D-3 Super Q II 16-44 Sizes Table D-3 Table D-5 Long Outlet Plus Silencer Mechanical Specifications Inlet Flange Q Adjustable Inlet VanesInlet Screen Q, SQ2 Inlet Bellmouth Q, SQ2FAN-DS-2

Fan specifications

Trane is a well-known name in the heating, ventilation, and air conditioning (HVAC) industry, and one of their standout products is the Trane Fan. Designed to provide efficient and effective airflow, the Trane Fan is a versatile solution suited for both residential and commercial applications.

One of the main features of the Trane Fan is its Energy Efficiency. With increasing energy costs, having a fan that operates efficiently is crucial. Trane fans are designed with advanced motor technology that enhances performance while reducing energy consumption. This not only helps lower utility bills but also contributes to a more sustainable environment.

The Variable Speed Technology is another notable characteristic. Trane fans come equipped with variable speed motors that adjust the airflow according to the specific needs of a space. This adaptability means that the fan can run at lower speeds, providing quiet operation while maintaining comfort levels, and ramping up power when needed for more intense cooling or ventilation.

Durability and robustness are core attributes of Trane fans. Constructed from high-quality materials, these fans are built to withstand harsh conditions and continue to function optimally over time. This longevity is essential for commercial settings where reliability is paramount.

Additionally, Trane delivers innovative sound-reduction technologies within their fan designs. Special engineering ensures that these units operate quietly, making them ideal for environments such as offices, schools, and homes where noise can be a distraction.

Another significant aspect is Smart Technology Integration. Trane fans are compatible with various smart home systems, allowing users to control their systems remotely. This feature enhances convenience, enabling homeowners and facility managers to monitor and adjust air quality effortlessly.

In terms of ease of installation, Trane Fans are designed with user-friendly features that facilitate quicker setup and less hassle. Their modular designs allow for flexibility in installation across various applications.

In summary, the Trane Fan stands out due to its energy efficiency, variable speed technology, durability, sound-reduction capabilities, smart technology integration, and ease of installation. These characteristics make Trane fans a reliable choice for enhancing indoor air quality across diverse environments.