LIMITED WARRANTY

Honeywell International Inc., 165 Eileen Way, Syosset, New York 11791, warrants its product(s) to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product(s) or, for product(s) not having a date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller’s obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product(s) which is proved not in compliance with Seller’s specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone other than Honeywell factory service. For warranty service, return product(s) transportation prepaid, to Honeywell Factory Service, 165 Eileen Way, Syosset, New York 11791.

THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER’S OWN NEGLIGENCE OR FAULT.

Seller does not represent that the product(s) it sells may not be compromised or circumvented; that the product(s) will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product(s) will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fire, or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result.

CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THAT THE PRODUCT(S) FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER’S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT(S), WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER.

This warranty replaces any previous warranties and is the only warranty made by Seller on this product(s). No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized.

– 67 –

Image 67
Contents $0&29,67$65,6 9,67$39,67$38 Page Table of Contents Emergency Evacuation Fire Alarm SystemUsing #70 Relay Menu Mode Programming Device TimersZones System OverviewGeneral Partitioned SystemFire Protection AlarmsMemory of Alarm System Overview cont’dSpeed Key Macros Using SchedulesDevice Timers To Access Another Partition Goto CommandTo view the abbreviated instructions Self-Help FeaturePhone Access & Voice Response Capability Master Keypad OperationAlpha Keypad About The KeypadsFunction Keys Functions Of The KeypadRemoves Individual Functions Of The Keypad cont’dFunctions Of The Keypad cont’d General Information Entry/Exit DelaysDuress Code Security Codes & Authority LevelsQuick Arming Authority Levels Security Codes & Authority Levels cont’dGeneral Rules on Authority Levels and Changes To Exit User Edit ModeCode To Add a UserMULTI-ACCESS ? 0 = no , 1 = YES To Delete a User To Change a User’s CodeTo Goto another partition Accessing Other PartitionsTo Access Another Partition Global ArmingGlobal Arming Notes Accessing Other Partitions cont’dStatus Whse Disarmed HIT for FaultsFault 002 Loading Dock Window SystemCommon Lobby Operation Other Methods of Arming/Disarming How User Codes Affect the Common LobbyCodes with Global Arming Codes with Non-Global ArmingChecking For Open Zones Using Ready KeyTo show faulted zones Typical fault displayDisplaying All Zone Descriptors Bypass 007 Front Upstairs Bedroom Using Bypass KeyBypassing Protection Zones To bypass zones, the system must be disarmed firstDisplaying Bypassed Zones To use the Quick Bypass featureBypassing Protection Zones cont’d Quick BypassArming Perimeter Only Using Stay keyArmed ***STAY Zone Bypassed Armed *INSTANT* Zone Bypassed Using the 7 Instant KeyArming All Protection Using Away KeyArmed **AWAY YOU MAY Exit NOW Armed *MAXIMUM* YOU MAY Exit NOW Using the 4 Maximum KeyDisarmed Ready to ARM Disarming And Silencing AlarmsUsing the 1 OFF Key To disarm the system and silence burglary or fire alarmsArming Using The KeyswitchDisarming Chime Mode OFF Chime ModeUsing Key Chime Mode onMESSAGE. Press For 5 Secs Viewing Alarm Company MessagesPanic Keys Using Panic KeysDefining Speed Key MacrosEnter Speed KEY D Executing Speed Key Macros cont’dEnter User Code Access Door Control Enter Device no Using #70 Relay Menu ModeTemporary Open/Close Schedules Using SchedulesDelaying the Closing Time Closing DELAY? KEY 0-2 HoursMON Disarm Wind AM 0845AM MON ARM Window 0745AM 0845AM Using Schedules cont’dProgramming Temporary Schedules To program temporary schedulesDays ? Mtwtfss HIT 0-7 X To enter the device timer menu mode Programming Device TimersPorch Lite Enter OUTPUT# DAYS? Mtwtfss HIT 0-7 X Permanent ? Programming Device Timers cont’dSelect the partition Event Log ProceduresEnter Code + # + 6 + Select the display mode Enter 0 = Recent 1 = CompleteAfter the last event has been Event Logging ProceduresUse the 3 & 1 keys for next Press 8 to select a categoryTesting Your System Using the 5 Test KeyCase Of Fire Alarm Fire Alarm SystemSilencing a Fire Alarm Typical Trouble Displays Trouble ConditionsTrouble Conditions cont’d Power FailureNon-Alpha Keypad Displays Recommendations For Smoke And Heat Detectors Recommendations For Proper ProtectionRecommendations For Proper Intrusion Protection Recommendations For Proper Protection cont’dAddition, we recommend the following Emergency Evacuation Maintaining Your System Replacing Batteries in Wireless SensorsTaking Care of Your System Maintaining Your System cont’d Silencing Low Battery Warning Tones at the KeypadRoutine Care Function Quick Guide To System FunctionsQuick Guide To System Functions cont’d Alpha Display Keypads Summary Of Audible NotificationFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Add User Code IndexQuick Guide Ready POWER/READY IndicatorLimited Warranty Page Page Page Page Eileen Way, Syosset, New York

VISTA-50P, VISTA-50PUL specifications

Honeywell's VISTA-50PUL and VISTA-50P are versatile and highly regarded security control panels ideal for residential and small commercial applications. These two models are designed to provide robust security capabilities while offering a range of features that enhance user convenience and system reliability.

The VISTA-50PUL and VISTA-50P both support up to 48 zones, which allows for extensive coverage and flexibility in securing various areas within a property. They offer integration with wired and wireless zones, making installation easier in diverse environments. The control panels can be utilized with Honeywell's array of sensors and detectors to create a comprehensive security solution.

One of the standout features of both models is their compatibility with Honeywell's Total Connect Remote Services. This functionality enables users to remotely access and control their security systems via smartphones, tablets, or computers. This capability gives homeowners and business managers peace of mind, as they can monitor their properties in real-time and receive alerts on potential security breaches.

In terms of communication technologies, the VISTA-50PUL and VISTA-50P are equipped with robust communication options, including both traditional phone line connectivity and newer IP-based systems. This flexibility allows users to choose how they want to communicate alarm signals to monitoring stations, ensuring that they remain connected even if traditional lines fail.

The panels also include features like programmable outputs, allowing integration with home automation systems and other security devices. Users can customize outputs to manage different devices, such as lights or alarms, enhancing both safety and convenience.

User-friendliness is another key aspect of the VISTA models. They include intuitive programming options and user-friendly interfaces for easy setup and operation. The keypads are designed with clear displays and responsive controls, making it easy for users to arm and disarm their systems, review event logs, and manage system settings.

Furthermore, both VISTA models are compatible with a variety of accessories, such as cameras, motion detectors, and safety devices, further expanding their effectiveness.

In conclusion, the Honeywell VISTA-50PUL and VISTA-50P are powerful security control panels that bring together advanced technology, user convenience, and extensive compatibility. Their ability to integrate with remote services and various security devices makes them an excellent choice for those looking to enhance their security systems.