FUNCTION

Check Zones

Display All Descriptors

Arm System

Disarm System

Bypass Zones

Quick Bypass

Chime Mode

Test Mode

View Messages

View User Capabilities

GOTO Partition

Self-Help

Add a User

Change a User’s Code

PROCEDURE

Press [].

Press and hold [] for 5 seconds.

Enter code.

Press arming key desired (AWAY,

STAY, INSTANT, MAXIMUM).

Enter code. Press OFF [1].

Enter code. Press BYPASS [6]. Enter zone numbers to be

bypassed (use 3-digit entries).

Enter code. Press BYPASS [6]. Press [#].

Enter code. Press CHIME [9].

Enter code. Press TEST [5]

Press and hold [0] for at least 5 seconds.

Enter user’s code. Press [] + [].

Enter security code. Press []. Enter partition number (1-8).

0 returns to default partition.

Press and hold any function key for at least 5 seconds.

Enter master/manager code. Press CODE [8].

Enter new user’s user number. Enter code for that user.

Enter authority for that user in this partition (1-5).

Follow prompts, 1=Yes, 0=No.

Enter master/manager code. Press CODE [8].

Enter user’s 3-digit number. Enter new code for that user. Press 0 (No) at prompt.

COMMENTS

To view faulted zones when is system not ready

Displays all alpha descriptors programmed by installer.

Arms system in mode selected.

Disarms system and silences alarms.

Bypassed zones are unprotected and will not cause an alarm if violated.

Bypasses all faulted zones automatically.

Keypad will sound if doors or windows are violated while system disarmed.

Activates alarm sounder and allows sensors to be tested.

Message from central station will appear.

Displays partitions & authority levels assigned to the user.

Allows a user at one keypad to perform functions in another partition, if that user is authorized to do so.

Will display abbreviated instructions for the key pressed.

Master & Manager level users can add users to the system, each with its own code and authority level.

Master & Manager level users can change their own or other users’ codes.

– 58 –

Image 58
Contents $0&29,67$65,6 9,67$39,67$38 Page Table of Contents Programming Device Timers Fire Alarm SystemUsing #70 Relay Menu Mode Emergency EvacuationPartitioned System System OverviewGeneral ZonesSystem Overview cont’d AlarmsMemory of Alarm Fire ProtectionTo Access Another Partition Goto Command Using SchedulesDevice Timers Speed Key MacrosMaster Keypad Operation Self-Help FeaturePhone Access & Voice Response Capability To view the abbreviated instructionsAbout The Keypads Alpha KeypadFunctions Of The Keypad Function KeysFunctions Of The Keypad cont’d Removes IndividualFunctions Of The Keypad cont’d Entry/Exit Delays General InformationDuress Code Security Codes & Authority LevelsQuick Arming Security Codes & Authority Levels cont’d Authority LevelsTo Exit User Edit Mode General Rules on Authority Levels and ChangesTo Add a User CodeMULTI-ACCESS ? 0 = no , 1 = YES To Change a User’s Code To Delete a UserGlobal Arming Accessing Other PartitionsTo Access Another Partition To Goto another partitionAccessing Other Partitions cont’d Global Arming NotesSystem Whse Disarmed HIT for FaultsFault 002 Loading Dock Window StatusCommon Lobby Operation Codes with Non-Global Arming How User Codes Affect the Common LobbyCodes with Global Arming Other Methods of Arming/DisarmingTypical fault display Using Ready KeyTo show faulted zones Checking For Open ZonesDisplaying All Zone Descriptors To bypass zones, the system must be disarmed first Using Bypass KeyBypassing Protection Zones Bypass 007 Front Upstairs BedroomQuick Bypass To use the Quick Bypass featureBypassing Protection Zones cont’d Displaying Bypassed ZonesArming Perimeter Only Using Stay keyArmed ***STAY Zone Bypassed Using the 7 Instant Key Armed *INSTANT* Zone BypassedArming All Protection Using Away KeyArmed **AWAY YOU MAY Exit NOW Using the 4 Maximum Key Armed *MAXIMUM* YOU MAY Exit NOWTo disarm the system and silence burglary or fire alarms Disarming And Silencing AlarmsUsing the 1 OFF Key Disarmed Ready to ARMArming Using The KeyswitchDisarming Chime Mode on Chime ModeUsing Key Chime Mode OFFViewing Alarm Company Messages MESSAGE. Press For 5 SecsUsing Panic Keys Panic KeysDefining Speed Key MacrosEnter Speed KEY D Executing Speed Key Macros cont’dEnter User Code Access Door Control Using #70 Relay Menu Mode Enter Device noClosing DELAY? KEY 0-2 Hours Using SchedulesDelaying the Closing Time Temporary Open/Close SchedulesTo program temporary schedules Using Schedules cont’dProgramming Temporary Schedules MON Disarm Wind AM 0845AM MON ARM Window 0745AM 0845AMDays ? Mtwtfss HIT 0-7 X To enter the device timer menu mode Programming Device TimersPorch Lite Enter OUTPUT# Programming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ?Enter 0 = Recent 1 = Complete Event Log ProceduresEnter Code + # + 6 + Select the display mode Select the partitionPress 8 to select a category Event Logging ProceduresUse the 3 & 1 keys for next After the last event has beenUsing the 5 Test Key Testing Your SystemCase Of Fire Alarm Fire Alarm SystemSilencing a Fire Alarm Trouble Conditions Typical Trouble DisplaysTrouble Conditions cont’d Power FailureNon-Alpha Keypad Displays Recommendations For Proper Protection Recommendations For Smoke And Heat DetectorsRecommendations For Proper Intrusion Protection Recommendations For Proper Protection cont’dAddition, we recommend the following Emergency Evacuation Maintaining Your System Replacing Batteries in Wireless SensorsTaking Care of Your System Maintaining Your System cont’d Silencing Low Battery Warning Tones at the KeypadRoutine Care Quick Guide To System Functions FunctionQuick Guide To System Functions cont’d Summary Of Audible Notification Alpha Display KeypadsFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Index Add User CodePOWER/READY Indicator Quick Guide ReadyLimited Warranty Page Page Page Page Eileen Way, Syosset, New York

VISTA-50P, VISTA-50PUL specifications

Honeywell's VISTA-50PUL and VISTA-50P are versatile and highly regarded security control panels ideal for residential and small commercial applications. These two models are designed to provide robust security capabilities while offering a range of features that enhance user convenience and system reliability.

The VISTA-50PUL and VISTA-50P both support up to 48 zones, which allows for extensive coverage and flexibility in securing various areas within a property. They offer integration with wired and wireless zones, making installation easier in diverse environments. The control panels can be utilized with Honeywell's array of sensors and detectors to create a comprehensive security solution.

One of the standout features of both models is their compatibility with Honeywell's Total Connect Remote Services. This functionality enables users to remotely access and control their security systems via smartphones, tablets, or computers. This capability gives homeowners and business managers peace of mind, as they can monitor their properties in real-time and receive alerts on potential security breaches.

In terms of communication technologies, the VISTA-50PUL and VISTA-50P are equipped with robust communication options, including both traditional phone line connectivity and newer IP-based systems. This flexibility allows users to choose how they want to communicate alarm signals to monitoring stations, ensuring that they remain connected even if traditional lines fail.

The panels also include features like programmable outputs, allowing integration with home automation systems and other security devices. Users can customize outputs to manage different devices, such as lights or alarms, enhancing both safety and convenience.

User-friendliness is another key aspect of the VISTA models. They include intuitive programming options and user-friendly interfaces for easy setup and operation. The keypads are designed with clear displays and responsive controls, making it easy for users to arm and disarm their systems, review event logs, and manage system settings.

Furthermore, both VISTA models are compatible with a variety of accessories, such as cameras, motion detectors, and safety devices, further expanding their effectiveness.

In conclusion, the Honeywell VISTA-50PUL and VISTA-50P are powerful security control panels that bring together advanced technology, user convenience, and extensive compatibility. Their ability to integrate with remote services and various security devices makes them an excellent choice for those looking to enhance their security systems.