Honeywell VISTA-50PUL manual Accessing Other Partitions cont’d, Global Arming Notes

Page 21

Accessing Other Partitions (cont’d)

ARM P 1 2 3 4 5 6 7 8

HIT 0-8 X X X - - X - -

Global Arming Notes:

The prompt displays all the partitions. The user may only arm/disarm the partitions they are assigned access to.

To select the partition(s) that are to be armed, enter the desired number 1-8. An "X" will appear under that partition. Entering a partition’s number again will delete the “X” and that partition will not arm when this prompt is exited.

Pressing 0 will turn all partitions the user is assigned access to on/off.

When completed, press to exit. All the partitions with the “X” will then arm/disarm.

When performing a Global Arm, if there are faults in any of the selected partitions, the system will enter a Summary Mode. Faulted zones in all the selected partitions will be displayed. These faults must be corrected or bypassed. This Summary Mode will end in approximately 120 seconds if no keys are pressed.

When performing a Global Disarm, if any of the selected partitions has a condition which would cause the keypad to beep (e.g., alarm memory or a trouble condition), the system enters a Summary Mode and displays the condition. This Summary Mode will end in approximately 120 seconds if no keys are pressed.

–21

Image 21
Contents $0&29,67$65,6 9,67$39,67$38 Page Table of Contents Using #70 Relay Menu Mode Fire Alarm SystemProgramming Device Timers Emergency EvacuationGeneral System OverviewPartitioned System ZonesMemory of Alarm AlarmsSystem Overview cont’d Fire ProtectionDevice Timers Using SchedulesTo Access Another Partition Goto Command Speed Key MacrosPhone Access & Voice Response Capability Self-Help FeatureMaster Keypad Operation To view the abbreviated instructionsAlpha Keypad About The KeypadsFunction Keys Functions Of The KeypadRemoves Individual Functions Of The Keypad cont’dFunctions Of The Keypad cont’d General Information Entry/Exit DelaysSecurity Codes & Authority Levels Duress CodeQuick Arming Authority Levels Security Codes & Authority Levels cont’dGeneral Rules on Authority Levels and Changes To Exit User Edit ModeCode To Add a UserMULTI-ACCESS ? 0 = no , 1 = YES To Delete a User To Change a User’s CodeTo Access Another Partition Accessing Other PartitionsGlobal Arming To Goto another partitionGlobal Arming Notes Accessing Other Partitions cont’dFault 002 Loading Dock Window Whse Disarmed HIT for FaultsSystem StatusCommon Lobby Operation Codes with Global Arming How User Codes Affect the Common LobbyCodes with Non-Global Arming Other Methods of Arming/DisarmingTo show faulted zones Using Ready KeyTypical fault display Checking For Open ZonesDisplaying All Zone Descriptors Bypassing Protection Zones Using Bypass KeyTo bypass zones, the system must be disarmed first Bypass 007 Front Upstairs BedroomBypassing Protection Zones cont’d To use the Quick Bypass featureQuick Bypass Displaying Bypassed ZonesUsing Stay key Arming Perimeter OnlyArmed ***STAY Zone Bypassed Armed *INSTANT* Zone Bypassed Using the 7 Instant KeyUsing Away Key Arming All ProtectionArmed **AWAY YOU MAY Exit NOW Armed *MAXIMUM* YOU MAY Exit NOW Using the 4 Maximum KeyUsing the 1 OFF Key Disarming And Silencing AlarmsTo disarm the system and silence burglary or fire alarms Disarmed Ready to ARMUsing The Keyswitch ArmingDisarming Using Key Chime ModeChime Mode on Chime Mode OFFMESSAGE. Press For 5 Secs Viewing Alarm Company MessagesPanic Keys Using Panic KeysSpeed Key Macros DefiningEnter Speed KEY D Speed Key Macros cont’d ExecutingEnter User Code Access Door Control Enter Device no Using #70 Relay Menu ModeDelaying the Closing Time Using SchedulesClosing DELAY? KEY 0-2 Hours Temporary Open/Close SchedulesProgramming Temporary Schedules Using Schedules cont’dTo program temporary schedules MON Disarm Wind AM 0845AM MON ARM Window 0745AM 0845AMDays ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modePorch Lite Enter OUTPUT# DAYS? Mtwtfss HIT 0-7 X Permanent ? Programming Device Timers cont’dEnter Code + # + 6 + Select the display mode Event Log ProceduresEnter 0 = Recent 1 = Complete Select the partitionUse the 3 & 1 keys for next Event Logging ProceduresPress 8 to select a category After the last event has beenTesting Your System Using the 5 Test KeyFire Alarm System Case Of Fire AlarmSilencing a Fire Alarm Typical Trouble Displays Trouble ConditionsPower Failure Trouble Conditions cont’dNon-Alpha Keypad Displays Recommendations For Smoke And Heat Detectors Recommendations For Proper ProtectionRecommendations For Proper Protection cont’d Recommendations For Proper Intrusion ProtectionAddition, we recommend the following Emergency Evacuation Replacing Batteries in Wireless Sensors Maintaining Your SystemTaking Care of Your System Silencing Low Battery Warning Tones at the Keypad Maintaining Your System cont’dRoutine Care Function Quick Guide To System FunctionsQuick Guide To System Functions cont’d Alpha Display Keypads Summary Of Audible NotificationFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Add User Code IndexQuick Guide Ready POWER/READY IndicatorLimited Warranty Page Page Page Page Eileen Way, Syosset, New York

VISTA-50P, VISTA-50PUL specifications

Honeywell's VISTA-50PUL and VISTA-50P are versatile and highly regarded security control panels ideal for residential and small commercial applications. These two models are designed to provide robust security capabilities while offering a range of features that enhance user convenience and system reliability.

The VISTA-50PUL and VISTA-50P both support up to 48 zones, which allows for extensive coverage and flexibility in securing various areas within a property. They offer integration with wired and wireless zones, making installation easier in diverse environments. The control panels can be utilized with Honeywell's array of sensors and detectors to create a comprehensive security solution.

One of the standout features of both models is their compatibility with Honeywell's Total Connect Remote Services. This functionality enables users to remotely access and control their security systems via smartphones, tablets, or computers. This capability gives homeowners and business managers peace of mind, as they can monitor their properties in real-time and receive alerts on potential security breaches.

In terms of communication technologies, the VISTA-50PUL and VISTA-50P are equipped with robust communication options, including both traditional phone line connectivity and newer IP-based systems. This flexibility allows users to choose how they want to communicate alarm signals to monitoring stations, ensuring that they remain connected even if traditional lines fail.

The panels also include features like programmable outputs, allowing integration with home automation systems and other security devices. Users can customize outputs to manage different devices, such as lights or alarms, enhancing both safety and convenience.

User-friendliness is another key aspect of the VISTA models. They include intuitive programming options and user-friendly interfaces for easy setup and operation. The keypads are designed with clear displays and responsive controls, making it easy for users to arm and disarm their systems, review event logs, and manage system settings.

Furthermore, both VISTA models are compatible with a variety of accessories, such as cameras, motion detectors, and safety devices, further expanding their effectiveness.

In conclusion, the Honeywell VISTA-50PUL and VISTA-50P are powerful security control panels that bring together advanced technology, user convenience, and extensive compatibility. Their ability to integrate with remote services and various security devices makes them an excellent choice for those looking to enhance their security systems.