Honeywell VISTA-50PUL manual Recommendations For Proper Protection cont’d

Page 54

Recommendations For Proper Protection (cont’d)

In addition, we recommend the following:

￿￿Install a smoke detector inside every bedroom where a smoker sleeps.

￿￿Install a smoke detector inside bedrooms where electrical appliances (such as portable heaters, air conditioners or humidifiers) are used.

￿￿Install a smoke detector inside every bedroom where someone sleeps with the door partly or completely closed. Smoke could be blocked by the closed door. Also, an alarm in the hallway outside may not wake up the sleeper if the door is closed.

￿￿Install a smoke detector at both ends of a hallway if the hallway is more than 40 feet (12 meters) long.

￿￿Install smoke detectors in any room where an alarm control is located, or in any room where alarm control connections to an AC source or phone lines are made. If detectors are not so located, a fire within the room could prevent the control from reporting a fire or an intrusion.

Recommendations For Proper Intrusion Protection

For proper intrusion coverage, sensors should be located at every possible point of entry to a home or commercial premises. This would include any skylights that may be present, and the upper windows in a multi-level building.

In addition, we recommend that radio backup be used in a security system so that alarm signals can still be sent to the alarm monitoring station in the event that the telephone lines are out of order (alarm signals are normally sent over the phone lines, if connected to an alarm monitoring station).

– 54 –

Image 54
Contents $0&29,67$65,6 9,67$39,67$38 Page Table of Contents Programming Device Timers Fire Alarm SystemUsing #70 Relay Menu Mode Emergency EvacuationPartitioned System System OverviewGeneral ZonesSystem Overview cont’d AlarmsMemory of Alarm Fire ProtectionTo Access Another Partition Goto Command Using SchedulesDevice Timers Speed Key MacrosMaster Keypad Operation Self-Help FeaturePhone Access & Voice Response Capability To view the abbreviated instructionsAbout The Keypads Alpha KeypadFunctions Of The Keypad Function KeysFunctions Of The Keypad cont’d Removes IndividualFunctions Of The Keypad cont’d Entry/Exit Delays General InformationSecurity Codes & Authority Levels Duress CodeQuick Arming Security Codes & Authority Levels cont’d Authority LevelsTo Exit User Edit Mode General Rules on Authority Levels and ChangesTo Add a User CodeMULTI-ACCESS ? 0 = no , 1 = YES To Change a User’s Code To Delete a UserGlobal Arming Accessing Other PartitionsTo Access Another Partition To Goto another partitionAccessing Other Partitions cont’d Global Arming NotesSystem Whse Disarmed HIT for FaultsFault 002 Loading Dock Window StatusCommon Lobby Operation Codes with Non-Global Arming How User Codes Affect the Common LobbyCodes with Global Arming Other Methods of Arming/DisarmingTypical fault display Using Ready KeyTo show faulted zones Checking For Open ZonesDisplaying All Zone Descriptors To bypass zones, the system must be disarmed first Using Bypass KeyBypassing Protection Zones Bypass 007 Front Upstairs BedroomQuick Bypass To use the Quick Bypass featureBypassing Protection Zones cont’d Displaying Bypassed ZonesUsing Stay key Arming Perimeter OnlyArmed ***STAY Zone Bypassed Using the 7 Instant Key Armed *INSTANT* Zone BypassedUsing Away Key Arming All ProtectionArmed **AWAY YOU MAY Exit NOW Using the 4 Maximum Key Armed *MAXIMUM* YOU MAY Exit NOWTo disarm the system and silence burglary or fire alarms Disarming And Silencing AlarmsUsing the 1 OFF Key Disarmed Ready to ARMUsing The Keyswitch ArmingDisarming Chime Mode on Chime ModeUsing Key Chime Mode OFFViewing Alarm Company Messages MESSAGE. Press For 5 SecsUsing Panic Keys Panic KeysSpeed Key Macros DefiningEnter Speed KEY D Speed Key Macros cont’d ExecutingEnter User Code Access Door Control Using #70 Relay Menu Mode Enter Device noClosing DELAY? KEY 0-2 Hours Using SchedulesDelaying the Closing Time Temporary Open/Close SchedulesTo program temporary schedules Using Schedules cont’dProgramming Temporary Schedules MON Disarm Wind AM 0845AM MON ARM Window 0745AM 0845AMDays ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modePorch Lite Enter OUTPUT# Programming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ?Enter 0 = Recent 1 = Complete Event Log ProceduresEnter Code + # + 6 + Select the display mode Select the partitionPress 8 to select a category Event Logging ProceduresUse the 3 & 1 keys for next After the last event has beenUsing the 5 Test Key Testing Your SystemFire Alarm System Case Of Fire AlarmSilencing a Fire Alarm Trouble Conditions Typical Trouble DisplaysPower Failure Trouble Conditions cont’dNon-Alpha Keypad Displays Recommendations For Proper Protection Recommendations For Smoke And Heat DetectorsRecommendations For Proper Protection cont’d Recommendations For Proper Intrusion ProtectionAddition, we recommend the following Emergency Evacuation Replacing Batteries in Wireless Sensors Maintaining Your SystemTaking Care of Your System Silencing Low Battery Warning Tones at the Keypad Maintaining Your System cont’dRoutine Care Quick Guide To System Functions FunctionQuick Guide To System Functions cont’d Summary Of Audible Notification Alpha Display KeypadsFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Index Add User CodePOWER/READY Indicator Quick Guide ReadyLimited Warranty Page Page Page Page Eileen Way, Syosset, New York

VISTA-50P, VISTA-50PUL specifications

Honeywell's VISTA-50PUL and VISTA-50P are versatile and highly regarded security control panels ideal for residential and small commercial applications. These two models are designed to provide robust security capabilities while offering a range of features that enhance user convenience and system reliability.

The VISTA-50PUL and VISTA-50P both support up to 48 zones, which allows for extensive coverage and flexibility in securing various areas within a property. They offer integration with wired and wireless zones, making installation easier in diverse environments. The control panels can be utilized with Honeywell's array of sensors and detectors to create a comprehensive security solution.

One of the standout features of both models is their compatibility with Honeywell's Total Connect Remote Services. This functionality enables users to remotely access and control their security systems via smartphones, tablets, or computers. This capability gives homeowners and business managers peace of mind, as they can monitor their properties in real-time and receive alerts on potential security breaches.

In terms of communication technologies, the VISTA-50PUL and VISTA-50P are equipped with robust communication options, including both traditional phone line connectivity and newer IP-based systems. This flexibility allows users to choose how they want to communicate alarm signals to monitoring stations, ensuring that they remain connected even if traditional lines fail.

The panels also include features like programmable outputs, allowing integration with home automation systems and other security devices. Users can customize outputs to manage different devices, such as lights or alarms, enhancing both safety and convenience.

User-friendliness is another key aspect of the VISTA models. They include intuitive programming options and user-friendly interfaces for easy setup and operation. The keypads are designed with clear displays and responsive controls, making it easy for users to arm and disarm their systems, review event logs, and manage system settings.

Furthermore, both VISTA models are compatible with a variety of accessories, such as cameras, motion detectors, and safety devices, further expanding their effectiveness.

In conclusion, the Honeywell VISTA-50PUL and VISTA-50P are powerful security control panels that bring together advanced technology, user convenience, and extensive compatibility. Their ability to integrate with remote services and various security devices makes them an excellent choice for those looking to enhance their security systems.