Honeywell VISTA-32FB, VISTA-128FB manual To Add a User, Code

Page 18

Security Codes & Authority Levels (cont’d)

To Add a User

IMPORTANT: Temporary users should not be shown how to use any system function they do not need to know (e.g. bypassing protection zones).

CODE

1. Enter Master or Manager code and press the

8

key.

2.Enter the new user’s 3-digit User Number (002-150).

3.Enter 4-digit security code for that user. The following prompts will appear.

ADD NEW USER? 0 = NO , 1 = YES

USER NUMBER = 003

ENTER AUTH. LEVEL

Enter 1 to add a new user code. Entering 0 will change the existing user’s code to the code entered in step 3. See Changing A User’s Code section.

Enter the authority level, 1-6, for this user within this partition.

1=master

2=manager

3=operator A

4=operator B

5=operator C

6=duress code

GROUP BYPASSING? 0 = NO , 1 = YES

ACCESS GROUP? ENTER 0-8

RF BUTTON ?

0 = NO , 1 = YES

Enter 1 (YES) to allow this user to perform group bypasses. Enter 0 (NO) this user will not be able to perform group bypasses.

If access schedules have been programmed, this prompt appears. Enter the user’s access group number (1-8) if this user should have limited access to the system. Enter 0 if no access group should be assigned.

This prompt will appear if a 5800 series button transmitter has been supplied and has not yet been assigned to a user. Press 1 if a button transmitter will be assigned to this user. Otherwise press 0.

ENTER BUTTON ZN # (001-128)

If assigning a button transmitter, this prompt will appear. Enter the button’s zone number (see your installer for zone number).

– 18 –

Image 18
Contents $0&29,67$65,6 9,67$%9,67$% Page Table of Contents Panic Keys System Overview GeneralZones System Overview cont’dPartitioned System Fire ProtectionBurglary Protection AlarmsMemory of Alarm Away Stay Instant MaximumTo Access Another Partition Goto Command Using SchedulesDevice Timers Speed Key MacrosMaster Keypad Operation Self-Help FeaturePhone Access & Voice Response Capability To view the abbreviated instructionsAbout The Keypads Alpha KeypadFunctions Of The Keypad Function Keys LCD DisplayFunctions Of The Keypad cont’d Removes IndividualFunctions Of The Keypad cont’d Entry/Exit Delays General InformationSecurity Codes & Authority Levels Duress CodeQuick Arming Security Codes & Authority Levels cont’d Authority LevelsTo Exit User Edit Mode General Rules on Authority Levels and ChangesTo Add a User CodeMULTI-ACCESS ? 0 = no , 1 = YES To Change a User’s Code To Delete a UserGlobal Arming Accessing Other PartitionsTo Access Another Partition To Goto another partitionAccessing Other Partitions cont’d SystemStatus Whse Disarmed HIT for Faults Fault 002 Loading Dock WindowCommon Lobby Operation Codes with Non-Global Arming How User Codes Affect the Common LobbyCodes with Global Arming Other Methods of Arming/DisarmingTypical fault display Using Ready KeyTo show faulted zones Checking For Open ZonesDisplaying All Zone Descriptors To bypass zones, the system must be disarmed first Using Bypass KeyBypassing Protection Zones Bypass 007 Front Upstairs BedroomQuick Bypass To use the Quick Bypass featureBypassing Protection Zones cont’d Displaying Bypassed ZonesUsing the 3 Stay key Arming Perimeter OnlyArmed ***STAY Zone Bypassed Using Instant Key Armed *INSTANT1 Zone BypassedUsing the 2 Away Key Arming All ProtectionArmed **AWAY YOU MAY Exit NOW Using Maximum Key Armed *MAXIMUM* YOU MAY Exit NOWTo disarm the system and silence burglary or fire alarms Disarming And Silencing AlarmsUsing the 1 OFF Key Disarmed Ready to ARMDisarming Using The KeyswitchArming To arm in the Stay mode, turnChime Mode on Chime ModeUsing Key Chime Mode OFFViewing Alarm Company Messages MESSAGE. Press For 5 SecsUsing Panic Keys Panic KeysSpeed Key Macros DefiningEnter Speed KEY # Executing Using Speed Key For Fire Alarm FunctionSpeed Key Macros cont’d Enter User CodeAccess Door Control Using #70 Relay Menu Mode Closing DELAY? KEY 0-2 Hours Using SchedulesDelaying the Closing Time Temporary Open/Close SchedulesTo program temporary schedules Using Schedules cont’dProgramming Temporary Schedules MON Disarm Wind AM 0845AM MON ARM Window 0745AM 0845AMDays ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modePorch Lite Enter OUTPUT# Programming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ?Using #77 Instant Activation Mode Action Code Action SpecifierUsing #77 Instant Activation Mode cont’d Bypass CommandsQuit Menu MODE? To enter the Instant Activation ModeAction ? Are YOU Sure ? Zone List ?Enter 0 = Recent 1 = Complete Event Log ProceduresEnter Code + # + 6 + Select the display mode Select the partitionBurglary C003 Event Logging ProceduresAlarm Event LOG To Exit the Event Log Press 4 at any timeUsing Test Key Testing Your SystemFire Alarm System Case Of Fire AlarmSilencing a Fire Alarm Fire Alarm System cont’d Fire Display LockFire Drill Test Code + # + Trouble Conditions Typical Trouble DisplaysPower Failure Trouble Conditions cont’dEmergency Evacuation Replacing Batteries in Wireless Sensors Maintaining Your SystemTaking Care of Your System Silencing Low Battery Warning Tones at the Keypad Maintaining Your System cont’dRoutine Care Quick Guide To System Functions FunctionQuick Guide To System Functions cont’d Summary Of Audible Notification Alpha Display KeypadsFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Index 4285 or 4286 VIP module AC LossReady Limited Warranty Page Eileen Way, Syosset, New York

VISTA-32FB, VISTA-128FB specifications

The Honeywell VISTA-128FB and VISTA-32FB are advanced security systems designed to provide robust protection and convenience for residential and commercial environments. These control panels are part of Honeywell's renowned VISTA series, offering a range of features that cater to diverse security needs.

The VISTA-128FB is ideal for larger installations, supporting up to 128 zones and providing enhanced flexibility and scalability. It accommodates a wide array of sensors and devices, making it suitable for complex security setups. Its ability to expand through plug-in modules allows users to tailor the system to their specific requirements. On the other hand, the VISTA-32FB supports up to 32 zones, making it an excellent choice for smaller properties while still delivering solid security capabilities.

One of the main features of both models is their ability to integrate with various communication technologies. They support standard hardwired zones as well as wireless zones through Honeywell's 5800 Series wireless devices. This feature ensures that properties can be outfitted with security devices without the need for extensive rewiring, providing greater installation flexibility.

These VISTA control panels also incorporate advanced technologies such as the Honeywell Total Connect Remote Services. This adds convenience by allowing users to monitor and control their security systems remotely via smartphones, tablets, or computers. Users receive real-time alerts and can arm or disarm their systems from anywhere, enhancing both security and peace of mind.

Both models are capable of providing two-way voice communication, which adds an extra layer of security by allowing direct communication with monitoring services in the event of an alarm activation. Furthermore, the VISTA-128FB and VISTA-32FB both feature programmable event log capabilities, allowing users to review system events and maintain a comprehensive record of security activities.

In terms of user interface, both systems are equipped with intuitive keypads that provide easy navigation through settings and options. Additionally, multiple partitioning capabilities allow for the segmented operation of various areas within a property, enhancing security management in multi-tenant buildings.

In summary, the Honeywell VISTA-128FB and VISTA-32FB control panels are sophisticated security solutions that offer extensive features and flexibility. Their ability to integrate advanced technologies and provide scalable options makes them an excellent choice for a variety of security needs, ensuring comprehensive protection for any environment.