Honeywell VISTA-128FB, VISTA-32FB manual Summary Of Audible Notification, Alpha Display Keypads

Page 63

Summary Of Audible Notification

(Alpha Display Keypads)

SOUND

LOUD,

INTERRUPTED* Keypad & External

LOUD,

CONTINUOUS* Keypad & External

ONE SHORT BEEP (not repeated) Keypad only

CAUSE

FIRE ALARM

BURGLARY/AUDIBLE EMERGENCY ALARM

a. SYSTEM DISARM

b. SYSTEM ARMING ATTEMPT WITH AN OPEN ZONE.

c. BYPASS VERIFY

DISPLAY

FIRE is displayed; descriptor of zone in alarm is displayed.

ALARM is displayed; descriptor of zone in alarm is also displayed.

a. DISARMED/READY TO ARM is displayed.

b. The number and descriptor of the open protection zone is displayed.

c.Numbers and descriptors of the bypassed protection zones are displayed (One beep is heard for each zone displayed). Subsequently, the following is displayed: DISARMED BYPASS Ready to Arm

ONE SHORT BEEP (once every 15 sec.) Keypad only

ONE BEEP (every 60 sec.) Keypad only

TWO SHORT BEEPS Keypad only

THREE SHORT

BEEPS

Keypad only

SYSTEM IS IN TEST MODE

LOW BATTERY AT A TRANSMITTER

ARM AWAY OR MAXIMUM

a. ARM STAY OR INSTANT

b. ZONE OPENED WHILE SYSTEM IS IN CHIME MODE.

c. ENTRY WARNING**

Opened Zone identifications will appear.

LO BAT displayed with description of transmitter.

ARMED AWAY or ARMED MAXIMUM is displayed. Red ARMED indicator is lit.

a. ARMED STAY ZONE BYPASSED or ARMED INSTANT ZONE BYPASSED is displayed. Red ARMED indicator is lit.

b. CHIME displayed, descriptor of open protection zone will be displayed if the [4] key is pressed.

c.DISARM SYSTEM OR ALARM WILL OCCUR is displayed.

RAPID BEEPING

Keypad only

a.TROUBLE

b.AC POWER LOSS ALERT***

c.MEMORY OF ALARM

a. CHECK displayed. Descriptor of troubled protection zone is displayed.

b. AC LOSS displayed (may alternate with other displays that may be present).

c.FIRE or ALARM is displayed; descriptor of zone in alarm is displayed.

SLOW BEEPING

a. ENTRY DELAY WARNING**

a. DISARM SYSTEM OR ALARM WILL OCCUR is

Keypad only

b. EXIT DELAY WARNING

displayed. Exceeding the delay time without

 

(if programmed)

disarming causes alarm.

 

 

b. ARMED AWAY or ARMED MAXIMUM is displayed

 

 

along with You May Exit Now

*If bell is used as Notification Appliance, fire alarm is pulsed ring; burglary/audible emergency is steady ring.

**Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer.

***Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power only).

63 –

Image 63
Contents $0&29,67$65,6 9,67$%9,67$% Page Table of Contents Panic Keys General System OverviewFire Protection System Overview cont’dPartitioned System ZonesAway Stay Instant Maximum AlarmsMemory of Alarm Burglary ProtectionSpeed Key Macros Using SchedulesDevice Timers To Access Another Partition Goto CommandTo view the abbreviated instructions Self-Help FeaturePhone Access & Voice Response Capability Master Keypad OperationAlpha Keypad About The KeypadsFunction Keys LCD Display Functions Of The KeypadRemoves Individual Functions Of The Keypad cont’dFunctions Of The Keypad cont’d General Information Entry/Exit DelaysSecurity Codes & Authority Levels Duress CodeQuick Arming Authority Levels Security Codes & Authority Levels cont’dGeneral Rules on Authority Levels and Changes To Exit User Edit ModeCode To Add a UserMULTI-ACCESS ? 0 = no , 1 = YES To Delete a User To Change a User’s CodeTo Goto another partition Accessing Other PartitionsTo Access Another Partition Global ArmingAccessing Other Partitions cont’d SystemStatus Fault 002 Loading Dock Window Whse Disarmed HIT for FaultsCommon Lobby Operation Other Methods of Arming/Disarming How User Codes Affect the Common LobbyCodes with Global Arming Codes with Non-Global ArmingChecking For Open Zones Using Ready KeyTo show faulted zones Typical fault displayDisplaying All Zone Descriptors Bypass 007 Front Upstairs Bedroom Using Bypass KeyBypassing Protection Zones To bypass zones, the system must be disarmed firstDisplaying Bypassed Zones To use the Quick Bypass featureBypassing Protection Zones cont’d Quick BypassUsing the 3 Stay key Arming Perimeter OnlyArmed ***STAY Zone Bypassed Armed *INSTANT1 Zone Bypassed Using Instant KeyUsing the 2 Away Key Arming All ProtectionArmed **AWAY YOU MAY Exit NOW Armed *MAXIMUM* YOU MAY Exit NOW Using Maximum KeyDisarmed Ready to ARM Disarming And Silencing AlarmsUsing the 1 OFF Key To disarm the system and silence burglary or fire alarmsTo arm in the Stay mode, turn Using The KeyswitchArming DisarmingChime Mode OFF Chime ModeUsing Key Chime Mode onMESSAGE. Press For 5 Secs Viewing Alarm Company MessagesPanic Keys Using Panic KeysSpeed Key Macros DefiningEnter Speed KEY # Enter User Code Using Speed Key For Fire Alarm FunctionSpeed Key Macros cont’d ExecutingAccess Door Control Using #70 Relay Menu Mode Temporary Open/Close Schedules Using SchedulesDelaying the Closing Time Closing DELAY? KEY 0-2 HoursMON Disarm Wind AM 0845AM MON ARM Window 0745AM 0845AM Using Schedules cont’dProgramming Temporary Schedules To program temporary schedulesDays ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modePorch Lite Enter OUTPUT# DAYS? Mtwtfss HIT 0-7 X Permanent ? Programming Device Timers cont’dAction Code Action Specifier Using #77 Instant Activation ModeBypass Commands Using #77 Instant Activation Mode cont’dZone List ? To enter the Instant Activation ModeAction ? Are YOU Sure ? Quit Menu MODE?Select the partition Event Log ProceduresEnter Code + # + 6 + Select the display mode Enter 0 = Recent 1 = CompleteTo Exit the Event Log Press 4 at any time Event Logging ProceduresAlarm Event LOG Burglary C003Testing Your System Using Test KeyFire Alarm System Case Of Fire AlarmSilencing a Fire Alarm Fire Alarm System cont’d Fire Display LockFire Drill Test Code + # + Typical Trouble Displays Trouble ConditionsTrouble Conditions cont’d Power FailureEmergency Evacuation Replacing Batteries in Wireless Sensors Maintaining Your SystemTaking Care of Your System Silencing Low Battery Warning Tones at the Keypad Maintaining Your System cont’dRoutine Care Function Quick Guide To System FunctionsQuick Guide To System Functions cont’d Alpha Display Keypads Summary Of Audible NotificationFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System 4285 or 4286 VIP module AC Loss IndexReady Limited Warranty Page Eileen Way, Syosset, New York

VISTA-32FB, VISTA-128FB specifications

The Honeywell VISTA-128FB and VISTA-32FB are advanced security systems designed to provide robust protection and convenience for residential and commercial environments. These control panels are part of Honeywell's renowned VISTA series, offering a range of features that cater to diverse security needs.

The VISTA-128FB is ideal for larger installations, supporting up to 128 zones and providing enhanced flexibility and scalability. It accommodates a wide array of sensors and devices, making it suitable for complex security setups. Its ability to expand through plug-in modules allows users to tailor the system to their specific requirements. On the other hand, the VISTA-32FB supports up to 32 zones, making it an excellent choice for smaller properties while still delivering solid security capabilities.

One of the main features of both models is their ability to integrate with various communication technologies. They support standard hardwired zones as well as wireless zones through Honeywell's 5800 Series wireless devices. This feature ensures that properties can be outfitted with security devices without the need for extensive rewiring, providing greater installation flexibility.

These VISTA control panels also incorporate advanced technologies such as the Honeywell Total Connect Remote Services. This adds convenience by allowing users to monitor and control their security systems remotely via smartphones, tablets, or computers. Users receive real-time alerts and can arm or disarm their systems from anywhere, enhancing both security and peace of mind.

Both models are capable of providing two-way voice communication, which adds an extra layer of security by allowing direct communication with monitoring services in the event of an alarm activation. Furthermore, the VISTA-128FB and VISTA-32FB both feature programmable event log capabilities, allowing users to review system events and maintain a comprehensive record of security activities.

In terms of user interface, both systems are equipped with intuitive keypads that provide easy navigation through settings and options. Additionally, multiple partitioning capabilities allow for the segmented operation of various areas within a property, enhancing security management in multi-tenant buildings.

In summary, the Honeywell VISTA-128FB and VISTA-32FB control panels are sophisticated security solutions that offer extensive features and flexibility. Their ability to integrate advanced technologies and provide scalable options makes them an excellent choice for a variety of security needs, ensuring comprehensive protection for any environment.