Honeywell VISTA-32FB, VISTA-128FB Programming Device Timers, To enter the device timer menu mode

Page 46

Programming Device Timers

General Information

Device timers consist of an ON time & an OFF time, and selected days of the week in which they are active. There are up to 20 timers that can be used to control various devices, such as lights or appliances. Your installer will have programmed the appropriate devices into the system (up to 96 devices can be programmed).

Each timer controls a single device (designated as an output number) that you select. For example, timer 1 might be set to turn the porch lights on at 7:00pm and turn them off at 11:00pm. Timer 2 might turn on the air conditioner Monday-Friday at 4:30pm to cool the premises before you arrive at 5:00pm, and turn it off at 10:00pm when you are retiring for the night. If desired, different timers can control the same device. For example, timer 2 could be used Monday-Friday as in the previous example, and timer 3 could be set to turn the air conditioner on and off at different times Saturday and Sunday.

To enter the device timer menu mode:

Enter your security code, then press the

#

key followed by 83.

See your installer for device numbers.

OUTPUT TIMER # ? 01-20,00=QUIT 01

06 07:00P 11:45P

PORCH LITE 04

00 ENTER OUTPUT#

00

Up to 20 timers can be programmed. Each timer is identified by a number 1-20. Enter the desired timer number to be programmed (1-20). Press * to accept entry.

If that timer number has already been programmed, a summary screen will appear. In this example:

06 = Timer #

04 = Output Device # affected by this timer PORCH LITE = Output Descriptor for Device 4 07:00PM = Start Time;

11:45PM = Stop Time Press * to continue.

Enter the desired output device number (1-96). As the number is entered, the device’s description will appear.

To delete a previously programmed timer, enter 00 as the output number.

– 46 –

Image 46
Contents $0&29,67$65,6 9,67$%9,67$% Page Table of Contents Panic Keys System Overview GeneralZones System Overview cont’dPartitioned System Fire ProtectionBurglary Protection AlarmsMemory of Alarm Away Stay Instant MaximumTo Access Another Partition Goto Command Using SchedulesDevice Timers Speed Key MacrosMaster Keypad Operation Self-Help FeaturePhone Access & Voice Response Capability To view the abbreviated instructionsAbout The Keypads Alpha KeypadFunctions Of The Keypad Function Keys LCD DisplayFunctions Of The Keypad cont’d Removes IndividualFunctions Of The Keypad cont’d Entry/Exit Delays General InformationDuress Code Security Codes & Authority LevelsQuick Arming Security Codes & Authority Levels cont’d Authority LevelsTo Exit User Edit Mode General Rules on Authority Levels and ChangesTo Add a User CodeMULTI-ACCESS ? 0 = no , 1 = YES To Change a User’s Code To Delete a UserGlobal Arming Accessing Other PartitionsTo Access Another Partition To Goto another partitionSystem Accessing Other Partitions cont’dStatus Whse Disarmed HIT for Faults Fault 002 Loading Dock WindowCommon Lobby Operation Codes with Non-Global Arming How User Codes Affect the Common LobbyCodes with Global Arming Other Methods of Arming/DisarmingTypical fault display Using Ready KeyTo show faulted zones Checking For Open ZonesDisplaying All Zone Descriptors To bypass zones, the system must be disarmed first Using Bypass KeyBypassing Protection Zones Bypass 007 Front Upstairs BedroomQuick Bypass To use the Quick Bypass featureBypassing Protection Zones cont’d Displaying Bypassed ZonesArming Perimeter Only Using the 3 Stay keyArmed ***STAY Zone Bypassed Using Instant Key Armed *INSTANT1 Zone BypassedArming All Protection Using the 2 Away KeyArmed **AWAY YOU MAY Exit NOW Using Maximum Key Armed *MAXIMUM* YOU MAY Exit NOWTo disarm the system and silence burglary or fire alarms Disarming And Silencing AlarmsUsing the 1 OFF Key Disarmed Ready to ARMDisarming Using The KeyswitchArming To arm in the Stay mode, turnChime Mode on Chime ModeUsing Key Chime Mode OFFViewing Alarm Company Messages MESSAGE. Press For 5 SecsUsing Panic Keys Panic KeysDefining Speed Key MacrosEnter Speed KEY # Executing Using Speed Key For Fire Alarm FunctionSpeed Key Macros cont’d Enter User CodeAccess Door Control Using #70 Relay Menu Mode Closing DELAY? KEY 0-2 Hours Using SchedulesDelaying the Closing Time Temporary Open/Close SchedulesTo program temporary schedules Using Schedules cont’dProgramming Temporary Schedules MON Disarm Wind AM 0845AM MON ARM Window 0745AM 0845AMDays ? Mtwtfss HIT 0-7 X To enter the device timer menu mode Programming Device TimersPorch Lite Enter OUTPUT# Programming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ?Using #77 Instant Activation Mode Action Code Action SpecifierUsing #77 Instant Activation Mode cont’d Bypass CommandsQuit Menu MODE? To enter the Instant Activation ModeAction ? Are YOU Sure ? Zone List ?Enter 0 = Recent 1 = Complete Event Log ProceduresEnter Code + # + 6 + Select the display mode Select the partitionBurglary C003 Event Logging ProceduresAlarm Event LOG To Exit the Event Log Press 4 at any timeUsing Test Key Testing Your SystemCase Of Fire Alarm Fire Alarm SystemSilencing a Fire Alarm Fire Display Lock Fire Alarm System cont’dFire Drill Test Code + # + Trouble Conditions Typical Trouble DisplaysPower Failure Trouble Conditions cont’dEmergency Evacuation Maintaining Your System Replacing Batteries in Wireless SensorsTaking Care of Your System Maintaining Your System cont’d Silencing Low Battery Warning Tones at the KeypadRoutine Care Quick Guide To System Functions FunctionQuick Guide To System Functions cont’d Summary Of Audible Notification Alpha Display KeypadsFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Index 4285 or 4286 VIP module AC LossReady Limited Warranty Page Eileen Way, Syosset, New York

VISTA-32FB, VISTA-128FB specifications

The Honeywell VISTA-128FB and VISTA-32FB are advanced security systems designed to provide robust protection and convenience for residential and commercial environments. These control panels are part of Honeywell's renowned VISTA series, offering a range of features that cater to diverse security needs.

The VISTA-128FB is ideal for larger installations, supporting up to 128 zones and providing enhanced flexibility and scalability. It accommodates a wide array of sensors and devices, making it suitable for complex security setups. Its ability to expand through plug-in modules allows users to tailor the system to their specific requirements. On the other hand, the VISTA-32FB supports up to 32 zones, making it an excellent choice for smaller properties while still delivering solid security capabilities.

One of the main features of both models is their ability to integrate with various communication technologies. They support standard hardwired zones as well as wireless zones through Honeywell's 5800 Series wireless devices. This feature ensures that properties can be outfitted with security devices without the need for extensive rewiring, providing greater installation flexibility.

These VISTA control panels also incorporate advanced technologies such as the Honeywell Total Connect Remote Services. This adds convenience by allowing users to monitor and control their security systems remotely via smartphones, tablets, or computers. Users receive real-time alerts and can arm or disarm their systems from anywhere, enhancing both security and peace of mind.

Both models are capable of providing two-way voice communication, which adds an extra layer of security by allowing direct communication with monitoring services in the event of an alarm activation. Furthermore, the VISTA-128FB and VISTA-32FB both feature programmable event log capabilities, allowing users to review system events and maintain a comprehensive record of security activities.

In terms of user interface, both systems are equipped with intuitive keypads that provide easy navigation through settings and options. Additionally, multiple partitioning capabilities allow for the segmented operation of various areas within a property, enhancing security management in multi-tenant buildings.

In summary, the Honeywell VISTA-128FB and VISTA-32FB control panels are sophisticated security solutions that offer extensive features and flexibility. Their ability to integrate advanced technologies and provide scalable options makes them an excellent choice for a variety of security needs, ensuring comprehensive protection for any environment.