Honeywell VISTA-32FB, VISTA-128FB Checking For Open Zones, Using Ready Key, To show faulted zones

Page 26

Checking For Open Zones

Using the

READY Key

Before arming your system, all protected doors, windows and other protection zones must be closed or bypassed (see BYPASSING section). Otherwise the keypad will display a "Not Ready" message. Using the READY key will display all zones that are faulted, making it easier for you to secure any open zones.

To show faulted zones:

DISARMED - PRESS

7TO SHOW FAULTS

Note: Some keypads light a green LED when the system is ready. If not lit, the system is not ready to be armed.

READY

1. Do not enter security code, but simply press

.

2.

FAULT 005 FRONT UPSTAIRS BEDROOM

DISARMED

READY TO ARM

Typical fault display

Secure or bypass the zones displayed before arming the system. The "Ready" message will

be displayedwhen all protection zones have been either closed or bypassed.

NOTE: All or part of this message may be replaced by a customized message programmed by the installer. Bear this in mind whenever the instructions indicate that the "DISARMED" or "READY" message will be displayed.

– 26 –

Image 26
Contents $0&29,67$65,6 9,67$%9,67$% Page Table of Contents Panic Keys System Overview GeneralZones System Overview cont’dPartitioned System Fire ProtectionBurglary Protection AlarmsMemory of Alarm Away Stay Instant MaximumTo Access Another Partition Goto Command Using SchedulesDevice Timers Speed Key MacrosMaster Keypad Operation Self-Help FeaturePhone Access & Voice Response Capability To view the abbreviated instructionsAbout The Keypads Alpha KeypadFunctions Of The Keypad Function Keys LCD DisplayFunctions Of The Keypad cont’d Removes IndividualFunctions Of The Keypad cont’d Entry/Exit Delays General InformationQuick Arming Security Codes & Authority LevelsDuress Code Security Codes & Authority Levels cont’d Authority LevelsTo Exit User Edit Mode General Rules on Authority Levels and ChangesTo Add a User CodeMULTI-ACCESS ? 0 = no , 1 = YES To Change a User’s Code To Delete a UserGlobal Arming Accessing Other PartitionsTo Access Another Partition To Goto another partitionStatus Accessing Other Partitions cont’dSystem Whse Disarmed HIT for Faults Fault 002 Loading Dock WindowCommon Lobby Operation Codes with Non-Global Arming How User Codes Affect the Common LobbyCodes with Global Arming Other Methods of Arming/DisarmingTypical fault display Using Ready KeyTo show faulted zones Checking For Open ZonesDisplaying All Zone Descriptors To bypass zones, the system must be disarmed first Using Bypass KeyBypassing Protection Zones Bypass 007 Front Upstairs BedroomQuick Bypass To use the Quick Bypass featureBypassing Protection Zones cont’d Displaying Bypassed ZonesArmed ***STAY Zone Bypassed Using the 3 Stay keyArming Perimeter Only Using Instant Key Armed *INSTANT1 Zone BypassedArmed **AWAY YOU MAY Exit NOW Using the 2 Away KeyArming All Protection Using Maximum Key Armed *MAXIMUM* YOU MAY Exit NOWTo disarm the system and silence burglary or fire alarms Disarming And Silencing AlarmsUsing the 1 OFF Key Disarmed Ready to ARMDisarming Using The KeyswitchArming To arm in the Stay mode, turnChime Mode on Chime ModeUsing Key Chime Mode OFFViewing Alarm Company Messages MESSAGE. Press For 5 SecsUsing Panic Keys Panic KeysEnter Speed KEY # Speed Key MacrosDefining Executing Using Speed Key For Fire Alarm FunctionSpeed Key Macros cont’d Enter User CodeAccess Door Control Using #70 Relay Menu Mode Closing DELAY? KEY 0-2 Hours Using SchedulesDelaying the Closing Time Temporary Open/Close SchedulesTo program temporary schedules Using Schedules cont’dProgramming Temporary Schedules MON Disarm Wind AM 0845AM MON ARM Window 0745AM 0845AMDays ? Mtwtfss HIT 0-7 X Porch Lite Enter OUTPUT# Programming Device TimersTo enter the device timer menu mode Programming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ?Using #77 Instant Activation Mode Action Code Action SpecifierUsing #77 Instant Activation Mode cont’d Bypass CommandsQuit Menu MODE? To enter the Instant Activation ModeAction ? Are YOU Sure ? Zone List ?Enter 0 = Recent 1 = Complete Event Log ProceduresEnter Code + # + 6 + Select the display mode Select the partitionBurglary C003 Event Logging ProceduresAlarm Event LOG To Exit the Event Log Press 4 at any timeUsing Test Key Testing Your SystemSilencing a Fire Alarm Fire Alarm SystemCase Of Fire Alarm Fire Drill Test Code + # + Fire Alarm System cont’dFire Display Lock Trouble Conditions Typical Trouble DisplaysPower Failure Trouble Conditions cont’dEmergency Evacuation Taking Care of Your System Replacing Batteries in Wireless SensorsMaintaining Your System Routine Care Silencing Low Battery Warning Tones at the KeypadMaintaining Your System cont’d Quick Guide To System Functions FunctionQuick Guide To System Functions cont’d Summary Of Audible Notification Alpha Display KeypadsFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Index 4285 or 4286 VIP module AC LossReady Limited Warranty Page Eileen Way, Syosset, New York