BEFORE YOU CALL FOR SERVICE
IF…
Air cleaner doesn’t seem to be working
Arcing (snapping) seems too frequent
If your air cleaner is equipped with the optional W8600E Solid State Performance Indicator, the WASH and CHECK LEDs on the W8600E will remind you that cell and prefilter washing is past due and tell you when the system is not operating properly. Whether or not your air cleaner has a Solid State Performance Indicator, perform these checks before you call your heating and air conditioning dealer for service.
THEN…
1.Make sure the switch is in the ON position.
2.Make sure the air cleaner fuse or circuit breaker is ok.
3.Make sure the furnace or air conditioner blower is running.
4.Make sure the access door is closed and securely latched. If the door is not closed, an interlock keeps the air cleaner OFF.
5.Check the neon light; if on, air cleaner is operating properly; if off, call for service.
1.If the electronic cell(s) are wet from washing, turn off the air cleaner for 2 to 3 hours.
2.Check the cell(s) for broken ionizer wires or bent plates. Repair if necessary.
3.Wash cell(s) and prefilter if dirty.
20 |