Honeywell F52F manual 69-0419-2

Page 23

The neon light on the air cleaner doesn’t come on

The WASH LED on the W8600E comes on

The CHECK LED on the W8600E comes on

You smell ozone and find it objectionable

1.Make sure the furnace or air conditioner blower is running.

2.On models without the Solid State Performance Indicator, if the electronic cells are wet, check again in 2 to 3 hours.

3.Make sure the appropriate fuse or circuit breaker is ok.

1.Cell and prefilter washing is past due; wash as soon as possible.

2.Make sure cell(s) are correctly installed in air cleaner.

3.Wipe ionizer wires to remove deposits. NOTE: Use the wash reminder schedule to establish a washing schedule that prevents the WASH LED from coming on.

1.Make sure cell(s) are clean and dry.

2.Check cell(s) for visible damage.

Call your heating and air conditioning dealer.

21

69-0419—2

Image 23
Contents Electronic AIR Cleaner Page Contents Solid State Performance Indicator ONE-CELL Model Shown Operating Your Electronic AIR CleanerONE-CELL Model Shown Getting the Most from Your AIR Cleaner Setting a regular cleaning schedule Cleaning the Cells and PrefilterStep Removing the electronic cells and prefilterBurn hazard Can cause personal injury Cleaning the prefilterStep Step At a car wash CleaningReplacing air cleaner components Washing the cellsCell Latch Insert TOP of Screen Close the door and fasten it with the two door latches Postage HOW Electronic AIR Cleaning WorksWord about Particle sizeHow the air Cleaner worksFurnace filter Air cleanerVs. the standard Electronic Vs. the airIonizer OzoneWhite dust About lint orTHEN… Before YOU Call for Service IF…69-0419-2 How to register your guarantee Honeywell 10 Year Clean Coil GuaranteeGuarantee 69-0419-2 Save Even More Energy With These Honeywell Accessories Limited TWO-YEAR Warranty Home and Building Control