DIAGNOSTICS FOR HONEYWELL CONTROL

LED Status

Control Status

 

Probable Cause

 

 

1. Gas valve is functioning

None (LED not on or

Millivolt power is not

 

normally

flashing)

present. Light pilot.

2.

Gas valve is not powered.

 

 

 

Light pilot

 

If set point knob is in

Gas valve is powered and waiting

 

for the set point knob to be turned

One flash and three

"PILOT" position then pilot

second pause.

flame is detected. (no

to a water temperature setting. If

the set point knob is at desired

 

faults).

 

setting the thermostat is satisfied.

 

 

LED strobe (two quick

Thermostat calling for heat

 

 

flashes) and three second

Water heater operating normally.

(no faults)

pause

 

 

 

 

Set point knob has been

Set point knob was recently turned

 

to "OFF" position. Wait until LED

LED on continuously.

recently turned to the

goes out before attempting to

 

"OFF" position.

 

relight

 

 

 

 

 

 

Two flashes and three

Weak pilot flame detected.

1.

Unstable pilot.

System will reset when

2.

Pilot tube blocked or

second pause.

pilot flame is sufficient.

 

restricted.

 

 

 

 

 

 

Three flashes and three

Insufficient water heating.

1.

Temperature sensor out of

second pause.

System will reset.

 

calibration.

2.

Possible short.

 

 

 

 

 

 

Four flashes and three

Excessive tank

1.

Temperature sensor out of

temperature. System must

 

calibration.

second pause.

 

be reset.

2.

Faulty gas valve.

 

 

 

 

 

 

 

1.

Damage to the temperature

 

 

 

wire.

 

 

2.

Temperature sensor

 

 

 

resistance out of range.

 

 

3.

Replace temperature sensor.

 

 

4.

If temperature sensor

Five flashes and three

 

 

replacement does not correct

Temperature sensor fault.

 

the problem; Verify control is

second pause.

 

 

 

not wet or physically damaged

 

 

 

 

 

5.

Turn set point knob to "OFF"

 

 

 

position. Turn set point knob

 

 

 

to "PILOT" position and light

 

 

 

pilot.

 

 

6.

Replace gas valve if five flash

 

 

 

error persists.

27

Image 27
Contents What to do if YOU Smell GAS For Your SafetyCongratulations Table of Contents General Information Installation Installation Locating The Water Heater If YOU Smell GAS Minimum Clearances Optional Direct VENT-AIR Intake Terminal Guard Installation Venting Direct Vent Terminal Clearances Venting Water Connections Approximate TIME/TEMPERATURE Relationships in ScaldsWater Connections Without First Being Certain IT is Filled with Water Gas Connections General Operation Page Lighting & Shutdown Instructions Honeywell gas control Thermostat Adjustment White Rodgers gas control Thermostat Adjusting Honeywell control Burner Flame Checks Maintenance Maintenance Maintenance Diagnostics for Honeywell Control Diagnostics for Honeywell Control Direct Vent Water Heater Parts List Part NameDescription Page

Gas Water Heater, 238-47969-00A specifications

The Honeywell 238-47969-00A Gas Water Heater is a premium choice for those seeking efficiency and reliability in their water heating solutions. This model stands out due to its advanced technology and innovative features, making it ideal for residential and commercial applications.

One of the key attributes of the Honeywell 238-47969-00A is its high efficiency design. It utilizes a powerful gas burner system that ensures quick heating of water, reducing wait times for hot water and enhancing user convenience. The energy-efficient operation not only conserves natural resources but also translates to lower utility bills, a benefit that is increasingly important for homeowners and businesses alike.

The water heater is equipped with an advanced control system that allows precise temperature regulation. This feature ensures that the water is heated to the desired temperature without fluctuations, providing consistent performance over time. Additionally, the unit includes a high-quality thermostat that monitors the water temperature, further optimizing energy consumption and performance.

Safety is a top priority for Honeywell, and the 238-47969-00A comes with multiple built-in safety features. These include flame failure protection, which automatically turns off the gas supply in the event of a flame out, and a temperature control mechanism that prevents overheating. Such features provide peace of mind and help guard against potential hazards.

Another noteworthy characteristic of the Honeywell 238-47969-00A is its durability. Constructed with high-grade materials, including corrosion-resistant components, the water heater is designed to withstand the rigors of everyday use. This durability not only extends the lifespan of the unit but also minimizes maintenance requirements.

Installation of the Honeywell gas water heater is straightforward, thanks to its user-friendly design. It is compatible with standard gas lines and is designed for easy integration into existing plumbing systems, which reduces installation time and costs.

In conclusion, the Honeywell 238-47969-00A Gas Water Heater combines efficiency, safety, and durability in a single package. Its advanced technology and user-centric features make it a standout choice in the competitive water heating market, ensuring reliable hot water access for years to come. Whether for a home or a commercial space, this gas water heater is poised to deliver exceptional performance while maximizing energy savings.