Honeywell 238-47969-00A, Gas Water Heater instruction manual Minimum Clearances

Page 8

Installation (Locating The Water Heater) continued-

The water heater must be located close enough to the outside wall to keep the venting distance within the maximum distance described in the vent kit’s installation instructions. Note: The direct vent-air intake terminal must be installed on a vertical wall. Read the instructions from the vent kit that was purchased with the water heater before locating the water heater.

This water heater must be located in an area where leakage of the tank or water line connections and the combination temperature and pressure relief valve will not result in damage to the area adjacent to the water heater or to lower floors of the structure. When such locations cannot be avoided, a suitable drain pan, adequately drained, must be installed under the water heater. The pan must not restrict combustion airflow. The drain pan must have a minimum length and width of at least 4 in. (10.2 cm) greater than the diameter of the water heater and must not restrict proper combustion air flow to the water heater. The drain pan, as described above, can be purchased from your plumbing professional. The drain pan must be piped to an adequate drain. The piping must be at least 3/4 inch (1.9 cm) in diameter and pitched for proper drainage.

It is recommended that a minimum clearance of four (4) inches (10.2 cm) be provided on the side of the water heater for servicing and maintenance of the combination temperature and pressure relief valve.

MINIMUM CLEARANCES

WARNING

Failure to adhere to these installation and operating instructions may create a hazard to life and property and will nullify the warranty.

This installation must allow access to the front of the water heater and adequate clearance must be provided for servicing and operating this water heater. The water heater may be installed on either a combustible or non-combustible floor. If the water heater is to be installed directly on carpeting, it must be installed on top of a metal or wood panel extending beyond the full width and depth of the appliance by at least three (3) inches (76.2 mm) in any direction or, if the appliance is to be installed in an alcove or closet, the entire floor must be covered by the panel. The minimum clearances to combustibles for this water heater is: zero (0) inch (0 cm) from the sides and rear, four (4) inches (10.2 cm) from the front of the jacket, zero

(0)inch (0 cm) from the plenum, zero (0) inch (0 cm) from the air intake tubes and twelve (12) inches (30.5 cm) from the direct vent-air intake terminal. (See Figure 1).

8

Image 8
Contents For Your Safety What to do if YOU Smell GASCongratulations Table of Contents General Information Installation Installation Locating The Water Heater If YOU Smell GAS Minimum Clearances Optional Direct VENT-AIR Intake Terminal Guard Installation Venting Direct Vent Terminal Clearances Venting Approximate TIME/TEMPERATURE Relationships in Scalds Water ConnectionsWater Connections Without First Being Certain IT is Filled with Water Gas Connections General Operation Page Lighting & Shutdown Instructions Honeywell gas control Thermostat Adjustment White Rodgers gas control Thermostat Adjusting Honeywell control Burner Flame Checks Maintenance Maintenance Maintenance Diagnostics for Honeywell Control Diagnostics for Honeywell Control Description Direct Vent Water Heater Parts ListPart Name Page

Gas Water Heater, 238-47969-00A specifications

The Honeywell 238-47969-00A Gas Water Heater is a premium choice for those seeking efficiency and reliability in their water heating solutions. This model stands out due to its advanced technology and innovative features, making it ideal for residential and commercial applications.

One of the key attributes of the Honeywell 238-47969-00A is its high efficiency design. It utilizes a powerful gas burner system that ensures quick heating of water, reducing wait times for hot water and enhancing user convenience. The energy-efficient operation not only conserves natural resources but also translates to lower utility bills, a benefit that is increasingly important for homeowners and businesses alike.

The water heater is equipped with an advanced control system that allows precise temperature regulation. This feature ensures that the water is heated to the desired temperature without fluctuations, providing consistent performance over time. Additionally, the unit includes a high-quality thermostat that monitors the water temperature, further optimizing energy consumption and performance.

Safety is a top priority for Honeywell, and the 238-47969-00A comes with multiple built-in safety features. These include flame failure protection, which automatically turns off the gas supply in the event of a flame out, and a temperature control mechanism that prevents overheating. Such features provide peace of mind and help guard against potential hazards.

Another noteworthy characteristic of the Honeywell 238-47969-00A is its durability. Constructed with high-grade materials, including corrosion-resistant components, the water heater is designed to withstand the rigors of everyday use. This durability not only extends the lifespan of the unit but also minimizes maintenance requirements.

Installation of the Honeywell gas water heater is straightforward, thanks to its user-friendly design. It is compatible with standard gas lines and is designed for easy integration into existing plumbing systems, which reduces installation time and costs.

In conclusion, the Honeywell 238-47969-00A Gas Water Heater combines efficiency, safety, and durability in a single package. Its advanced technology and user-centric features make it a standout choice in the competitive water heating market, ensuring reliable hot water access for years to come. Whether for a home or a commercial space, this gas water heater is poised to deliver exceptional performance while maximizing energy savings.