Honeywell PRO-2200 installation manual Description, Set Up, Jumper, Setting, Default, Selected

Page 9
Description

PRO-2200 Two Reader Module PRO22R2

Installation Guide

9

Description

The Two Reader Board provides support for up to two access control doors by providing connections for Wiegand or Clock/Data type readers, supervised inputs and relay outputs. This board can be rack mounted, in which case, only one edge is accessible for wiring. Mounting the board flat increases the amount of available I/O slightly but also significantly decreases the number of boards that can be mounted in one enclosure.

The I/O terminals are organized to support two doors. Starting at the bottom of the rack- mount side of the board, the first connector provides power to the board. The next connec- tor provides communication with the Intelligent Controller (PRO22IC). The next set of terminals is used to connect reader 2. The next set of terminals is used to connect the I/O typically associated with reader 2, namely the Door Status and REX status inputs and the Door Lock and Lock Status relay outputs. Continuing up this edge the next two connec- tors provide the reader and associated I/O terminals for reader 1. The last connector on the rack-mount edge provides terminals for two additional general-purpose alarm inputs

When the board is mounted flat, two additional relay outputs and two additional general- purpose alarm inputs are available along with two dedicated alarm inputs for cabinet tamper and power fault detection on the opposite edge of the board.

The reader interface accepts a Wiegand signal of Data 1 and Data 0 or a Clock and Data signal and provides 5 VDC or 12 VDC reader power, a tri-stated LED control and buzzer control. Two of the six form-C relay outputs are sized for the inductive load of door locks and the other four are designed to handle dry-circuit signals. All of the inputs are capable of four-state supervision except the two dedicated inputs. Communication to the control panel is accomplished via an RS-485 interface. This board requires 12 VDC input power.

When communication to the control panel is lost this board can grant access based on facility code only. General purpose outputs will retain the setting at the time communica- tion was lost. Up to eight facility codes may be active in each PRO22R2. Keypad input must follow the reader input format and is in place of or multiplexed with the reader data.

Set Up

Jumper Settings:

Jumper

Setting

Default

Selected

 

 

 

 

J1

OFF

*

Port 1 RS-485 EOL terminator is not active

 

 

 

 

ON

 

Port 1 RS-485 EOL terminator is active

 

 

J2

5

*

Reader 1

Power Terminal provides 5 VDC

 

 

 

 

12

 

Reader 1

Power Terminal provides 12 VDC

 

 

J3

5

*

Reader 2

Power Terminal provides 5 VDC

12

 

Reader 2

Power Terminal provides 12 VDC

 

 

 

 

 

 

 

Image 9
Contents PRO-2200 Two Reader Module Installation Manual Part Number PRO22R2A division of Northern Computers, Inc Page Contents Fire Safety and Liability Notice Warnings and CautionsPage Unpacking Procedure DisclaimerProduct Liability Mutual Indemnification Limited Warranty Shipping InstructionsTo ship equipment back to Engineered Systems Confidentiality Installation GuidePRO-2200Two Reader Module PRO22R2 Description Set UpSetting Default= Default Dipswitch SettingsInstallation Guide PRO-2200Two Reader Module PRO22R2LED Operation PowerCommunications MODEReader Wiring For Wiring to an RS-485portFor wiring to a reader port Control Output Wiring Alarm Contact WiringSingle Wire Reader LED Control Configuration LED OutputSuggested Installation Sequence Mounting OptionsSee diagram to follow Primary power 12VDC±10% 400mA Relay contacts SpecificationInputs Reader interfaceInstallation Guide Wiring Diagram for Connectors 1 throughPower VDC Separate - Power VDC Supply +Wiring Diagram for Connectors 6 through Installation GuidePRO-2200Two Reader Module PRO22R2 PRO-2200Two Reader Module PRO22R2 Installation GuidePage 2700 Blankenbaker Pkwy, Suite Louisville, KY Honeywell Security & Data Collection