Honeywell Galaxy 2 manual User 1 *1234 UserL2, = Master

Page 17

0 1 User 1 *1234

User(L2)

The A> and B< keys are used to select the user to be edited. Pressing ent will show the options for that user, starting with the PIN option. Again, the A> and B< keys can be used to move between the options. Pressing the ent key allows the displayed option to be modified. Most users can only access the PIN option. Only Master users can access the other functions. The programmable options for each user are listed below:

1 = PIN

This allows a new 4, 5, or 6 digit PIN code to be entered.

2 = Type

 

This allows the user type to be selected. There are 4 types available to choose from:

0 = Cleaner

Can only set and unset the system

1 = User

Can do all day-to-day operation but cannot override fault conditions

2 = Manager

As per User but can override faults and reset alarms and tampers

3 = Master

As per Manager but can add, remove and alter user codes.

3 = Group(s)

If group choice is enabled, this will allow the groups that the user has access to to be altered. The numbers shown on the display indicate the groups that the user has access to. Pressing the appropriate number key toggles the group on or off.

4 = Name

This allows a 6-character label to be assigned to the user, to aid identification when viewing the event log.

5 = RF Fob

This allows a wireless keyfob to be assigned to the user. The fob serial number is shown in the bottom row. If a new fob is to be assigned it should be ‘learned’ in as follows:

1. Press the star (*) key to start the learn process.

2. Press any button on the keyfob. The display will indicate success.

If a keyfob needs to be deleted, while the serial number is displayed, press the B< key to delete the serial number then press ent.

6 = Prox Tag (Mk7 Keyprox Units Only)

NOTE: For programming prox tags onto a 6160 keyprox, use menu 5 = RF Fob, but hold the tag up in place of steps 1 and 2.

This option allows a prox tag to be entered or deleted. On entering the option, the serial number of the current tag that is programmed will be displayed. To delete the current tag, press the B< key until the serial number is cleared then press ent. To program a new tag, clear any current serial number then press the 1 and A> keys simultaneously then present the new tag in front of the prox symbol. The new serial number should appear on the screen. Press the ent key to save the new number.

13

Image 17
Contents Galaxy 2 Series Page Table of Contents Iii Page Introduction Groups Controlling Your Alarm SystemUsers Prox Tags/Cards Keypads060 Setting the System Full SetWireless Keyfobs 030 Setting the System Part or Night SetOpen Zone 1044 Cancelling System Setting Setting with FaultsUnsetting Fault Override EventsAlert Conditions Cancelling an AlarmHow to Restore an Alarm Setting and Unsetting Without Group Choice Setting and Unsetting GroupsSetting and Unsetting With Group Choice Hot Keys10 = Setting 20 = Display 30 = Test 40 = Modify Menu Access10 = Setting ent to Select Menu 12 Timed Set Menu 11 Omit ZonesMenu 13 Part Set Menu 14 Night SetMenu 22 View Log 0951 01/08/04 1021+ IntruderMenu 23 Display Version Menu 24 PrintMenu 32 Output Test Menu 31 Walk TestMenu 41 Time/Date Menu 42 Editing Users= Master User 1 *1234 UserL2Menu 44 Mobile Numbers Menu 47 Remote AccessMenu 48 Level 3 Access Zone Reference Table Installer DetailsIU1-0032 Rev

Galaxy 2 specifications

The Honeywell Galaxy 2 is a sophisticated intruder alarm control panel renowned for its versatility and advanced security features. This advanced system is designed to provide comprehensive protection for residential and commercial premises, ensuring peace of mind for users.

At the heart of the Galaxy 2 is its highly flexible architecture, which allows users to customize the system according to their specific security needs. The control panel supports multiple zones, enabling the installation of numerous sensors and detectors across large areas. This feature allows for effective monitoring and protection in various environments, making it ideal for both homes and businesses.

One of the standout characteristics of the Honeywell Galaxy 2 is its user-friendly interface. The control panel is equipped with an intuitive keypad and an LCD display, allowing users to navigate through different functions easily. This user-centric design ensures that individuals, regardless of their technical skill level, can operate the system without frustration.

In terms of communication technologies, the Galaxy 2 comes with advanced options for connectivity. It supports both wired and wireless connections, which adds to its flexibility during installation. The system can integrate seamlessly with a range of sensors, including motion detectors, door contacts, and glass break detectors, enhancing the overall security capability.

The Galaxy 2 system also includes powerful remote monitoring capabilities. Users can manage and monitor their security system via mobile devices, allowing for real-time alerts and control from virtually anywhere. This functionality not only provides convenience but also enhances the security response time.

Another essential feature of the Honeywell Galaxy 2 is its built-in event logging capability. This feature allows users to review a comprehensive log of system events, such as alarm activations and system status changes, helping in analyzing security incidents and improving response strategies.

Additionally, the Galaxy 2 is designed with scalability in mind. As security needs evolve, the system can be easily expanded with additional zones or connected devices, ensuring that users have ongoing protection without the need for a complete system overhaul.

In summary, the Honeywell Galaxy 2 is a robust and adaptable security solution equipped with advanced technologies, a user-friendly interface, and extensive features that cater to diverse security requirements. Its combination of flexibility, remote management, and scalability makes it a trusted choice for safeguarding properties effectively.