Honeywell Galaxy 2 manual Setting and Unsetting Groups, Hot Keys

Page 12

Setting and Unsetting Groups

It is possible to split the alarm system into separate areas or ‘Groups’ that can be set and unset independently. Different users can be given access to only certain groups, or to all groups. Also, individual users can be given the option of simply setting and unsetting all groups assigned to their code or choosing which groups to set or unset each time.

Setting and Unsetting Without Group Choice

When a user with access to multiple Groups, but no group choice, wants to set or unset, they should follow the standard procedures on the previous pages.

Setting and Unsetting With Group Choice

With group choice, setting is initiated as normal, using a code, tag or fob. However, a choice of groups will then be displayed along with the current status of each group.

The status can be changed for each group by pressing the appropriate number button and the display will cycle through the possible options.

SET 123

GROUPS SUU

S = SET

U = UNSET

Pressing the ent key will implement the status shown.

If a code, keyfob or tag is used while an entry timer is running or an alarm is in progress, the group that is active will be unset immediately, without any status needing to be changed on the keypad.

Hot Keys

When set by the engineer, three hot key functions are available on the keypads, by pressing a combination of two buttons. The three functions are Fire, Panic and Assistance. The Panic function can be extended to include keyfobs. The button combinations vary depending on keypad/keyfob type and are listed below.

Mk7LCDKeypad:

Fire

* and 8

 

Panic

* and 2

 

Assistance

* and 5

6160 Keypad:

Fire

3 and #

 

Panic

* and #

 

Assistance

1 and *

NOTE: Local regulations may prohibit the use of the hot-key function.

5804 Keyfob:

Panic

lower two buttons

KTC805 Keyfob:

Panic

Buttons 1 and 3 (marked SOS)

8

Image 12
Contents Galaxy 2 Series Page Table of Contents Iii Page Introduction Controlling Your Alarm System UsersGroups Keypads Prox Tags/CardsSetting the System Full Set Wireless Keyfobs060 Setting the System Part or Night Set Open Zone 1044030 Setting with Faults Cancelling System SettingUnsetting Fault Override EventsCancelling an Alarm How to Restore an AlarmAlert Conditions Setting and Unsetting Groups Setting and Unsetting Without Group ChoiceSetting and Unsetting With Group Choice Hot KeysMenu Access 10 = Setting ent to Select10 = Setting 20 = Display 30 = Test 40 = Modify Menu 11 Omit Zones Menu 12 Timed SetMenu 13 Part Set Menu 14 Night Set0951 01/08/04 1021+ Intruder Menu 22 View LogMenu 23 Display Version Menu 24 PrintMenu 31 Walk Test Menu 32 Output TestMenu 41 Time/Date Menu 42 Editing UsersUser 1 *1234 UserL2 = MasterMenu 47 Remote Access Menu 48 Level 3 AccessMenu 44 Mobile Numbers Installer Details Zone Reference TableIU1-0032 Rev

Galaxy 2 specifications

The Honeywell Galaxy 2 is a sophisticated intruder alarm control panel renowned for its versatility and advanced security features. This advanced system is designed to provide comprehensive protection for residential and commercial premises, ensuring peace of mind for users.

At the heart of the Galaxy 2 is its highly flexible architecture, which allows users to customize the system according to their specific security needs. The control panel supports multiple zones, enabling the installation of numerous sensors and detectors across large areas. This feature allows for effective monitoring and protection in various environments, making it ideal for both homes and businesses.

One of the standout characteristics of the Honeywell Galaxy 2 is its user-friendly interface. The control panel is equipped with an intuitive keypad and an LCD display, allowing users to navigate through different functions easily. This user-centric design ensures that individuals, regardless of their technical skill level, can operate the system without frustration.

In terms of communication technologies, the Galaxy 2 comes with advanced options for connectivity. It supports both wired and wireless connections, which adds to its flexibility during installation. The system can integrate seamlessly with a range of sensors, including motion detectors, door contacts, and glass break detectors, enhancing the overall security capability.

The Galaxy 2 system also includes powerful remote monitoring capabilities. Users can manage and monitor their security system via mobile devices, allowing for real-time alerts and control from virtually anywhere. This functionality not only provides convenience but also enhances the security response time.

Another essential feature of the Honeywell Galaxy 2 is its built-in event logging capability. This feature allows users to review a comprehensive log of system events, such as alarm activations and system status changes, helping in analyzing security incidents and improving response strategies.

Additionally, the Galaxy 2 is designed with scalability in mind. As security needs evolve, the system can be easily expanded with additional zones or connected devices, ensuring that users have ongoing protection without the need for a complete system overhaul.

In summary, the Honeywell Galaxy 2 is a robust and adaptable security solution equipped with advanced technologies, a user-friendly interface, and extensive features that cater to diverse security requirements. Its combination of flexibility, remote management, and scalability makes it a trusted choice for safeguarding properties effectively.