White Rodgers 1F95CA-391 specifications Troubleshooting, Reset Button

Page 10

TROUBLESHOOTING

RESET BUTTON

If the thermostat does not respond when keys are pressed, or the thermostat is not operating properly, you may use the reset button located on the back of the thermostat body (see fig. 2). Thermostat programming and configuration will not be affected by pressing the reset button. However, the clock will need to be reset.

RESETTING THERMOSTAT CONFIGURATION AND PROGRAMMING

The thermostat can be reset back to default programs and configuration. Removing power from the thermostat will not reset it, because the default settings are maintained in permanent memory. Before resetting the thermostat, you may want to make note of the previously selected configuration and programming. You must reconfigure and

reprogram the thermostat after resetting it using this method.

To reset the thermostat, press and release PROGRAM RUN , then press the FAN ,

TIME BACK and buttons at the same time. This will reset the thermostat to factory default programs and configuration. The display will momentarily go blank, then all segments on the display will momentarily be shown. The thermostat will then go into the HOLD mode and will maintain factory preset temperatures.

TROUBLESHOOTING

 

 

 

 

 

Symptom

 

Possible Cause

 

Corrective Action

 

 

 

 

 

 

 

Thermostat Does Not Follow Program

 

1. AM or PM set incorrectly in program.

 

Check current clock and program settings including

 

 

2.

AM or PM set incorrectly on clock.

 

AM or PM designations for each time period. If a

 

 

3.

Voltage spike or static discharge.

 

voltage spike or a static discharge occurs use

 

 

 

 

 

the reset operation listed above.

 

 

 

 

 

Blank Display and/or Keypad Not Responding

 

1. Voltage spike or static discharge.

 

Replace batteries and check heat/cool system

 

 

2.

Battery change required.

 

for proper operation. If a voltage spike occurs

 

 

 

 

 

use the Reset Operation listed above.

 

 

 

 

 

No Heat/No Cool/No Fan

 

1. Blown fuse or tripped circuit breaker.

 

Replace fuse or reset breaker.

(Common Problems)

 

2. Furnace power switch to OFF.

 

Turn switch to ON.

 

 

3.

Furnace blower compartment door or

 

Replace door panel in proper position to engage

 

 

 

panel loose or not properly installed.

 

safety interlock or door switch.

 

 

 

 

 

No Heat

 

1. Pilot light not lit.

 

Re-light pilot.

 

 

2.

SYSTEM button not pressed to display HEAT.

 

Set SYSTEM button until HEAT is displayed and

 

 

 

 

 

raise temperature above room temperature.

 

 

3.

Loose connection to thermostat or system.

 

Verify thermostat and system wires are securely

 

 

 

 

 

attached.

 

 

4.

Furnace Lock-Out Condition. Heat may also

 

Many furnaces have safety devices that shut

 

 

 

be intermittent.

 

down when a lock-out condition occurs. If the

 

 

 

 

 

heat works intermittently contact the furnace

 

 

 

 

 

manufacturer or local service person for

 

 

 

 

 

assistance.

 

 

5.

Heating system requires service or

 

Diagonistic: Set SYSTEM button until HEAT is

 

 

 

thermostat requires replacement.

 

displayed and raise setpoint above room

 

 

 

 

 

temperature.Within a few seconds the thermostat

 

 

 

 

 

should make a soft click sound. This sound

 

 

 

 

 

usually indicates the thermostat is operating

 

 

 

 

 

properly. If the thermostat does not click, try the

 

 

 

 

 

reset operation listed on the previous page. If the

 

 

 

 

 

thermostat does not click after being reset

 

 

 

 

 

contact your heating and cooling service person

 

 

 

 

 

or place of purchase for replacement. If the

 

 

 

 

 

thermostat clicks, contact the furnace manufacturer

 

 

 

 

 

or a service person to verify the heating system is

 

 

 

 

 

operating correctly.

 

 

 

 

 

 

10

Image 10
Contents Description SpecificationsPrecautions Electrical DataRemove OLD Thermostat InstallationConfiguring and PROGRAM- Ming Attach Base to WallMULTI-STAGE Terminal Outputs Heat Pump Terminal OutputsE2/P Switch DHM Terminal Function SwitchesReset Switch Reset switch E2/P switchInstaller Configuration Installer Table TimeDisabling Automatic Changeover Mode Compressor OFF DelayBalance Point Temperature Balance PointService Reminder Check Thermostat Operation Resetting Thermostat Configuration and Programming TroubleshootingReset Button TroubleshootingNo Cool Narrow or wide temperature swingThermostat Setting and Thermostat Heat, Cool or Fan Runs ConstantlyWhy is the temperature change Why does the system run withSetpoint and room temperature What is the thermostat Click Test?

1F95CA-391 specifications

The White Rodgers 1F95CA-391 is a multifunctional smart thermostat designed to offer homeowners greater control over their heating and cooling systems. As part of the HVAC industry’s move toward smarter technology, this device blends user-friendly features with advanced automation to enhance energy efficiency and comfort.

One of the standout features of the White Rodgers 1F95CA-391 is its compatibility with multiple heating and cooling systems. It supports conventional, heat pump, and auxiliary heat setups, making it versatile for a wide range of homes and setups. This flexibility ensures that virtually any homeowner can easily integrate it into their existing HVAC system without extensive modifications.

The thermostat boasts a user-friendly touchscreen interface that simplifies programming and daily adjustments. The intuitive design allows users to set schedules based on their daily routines easily. This feature ensures that heating and cooling systems operate only when needed, thereby reducing energy consumption and lowering utility bills.

Another key characteristic of the White Rodgers 1F95CA-391 is its Wi-Fi connectivity. This technology enables homeowners to monitor and control their thermostats remotely via a smartphone or tablet. Users can adjust temperatures, view system status, and even receive alerts about potential issues, ensuring peace of mind and convenience.

Energy-saving technologies are also at the forefront of the White Rodgers 1F95CA-391’s design. It incorporates energy-saving algorithms that learn user preferences and adjust heating and cooling schedules accordingly. Additionally, features such as two-stage heating and cooling management enhance performance while helping to optimize energy consumption.

The White Rodgers 1F95CA-391 is equipped with advanced filtration reminders that alert users when it’s time to change the HVAC system’s filters. Regular filter changes not only prolong the life of the system but also improve indoor air quality.

Lastly, the device is designed with a sleek and modern aesthetic, making it a stylish addition to any home decor. The clear display is easy to read, and the overall design is compact, allowing it to blend seamlessly within any environment.

In summary, the White Rodgers 1F95CA-391 thermostat combines cutting-edge technology with ease of use. Its compatibility with various HVAC systems, remote access capabilities, and focus on energy efficiency make it a valuable investment for any homeowner looking to enhance comfort while optimizing energy use.