White Rodgers 1F95CA-391 specifications Check Thermostat Operation

Page 9

CHECK THERMOSTAT OPERATION

FAN OPERATION

If your system does not have a G terminal Connection, skip to HEATING SYSTEM section below.

1.Turn power on to the system.

2.Press PROGRAM RUN .

3.

Press

FAN

until FAN ON is displayed.

 

The fan should begin to operate.

4.

Press

FAN

until FAN AUTO is

 

displayed. The fan should stop operating.

HEATING SYSTEM

1.Press PROGRAM RUN .

2.Press SYSTEM until HEAT is displayed. If the heating system has a standing pilot, ensure that it is lit.

3.Press the to adjust thermostat setting above room temperature. The

heating system should begin to operate.

4.Press the to adjust thermostat setting below room temperature. The

heating system should stop operating.

COOLING SYSTEM

!CAUTION

To prevent compressor and/or property damage, if the outdoor temperature is below 50°F (10°C), DO NOT operate the cooling system.

1.Press the PROGRAM RUN .

2.Press SYSTEM until COOL is displayed.

3.Press to adjust thermostat setting below room temperature. The fan should

come on (after the fan-on delay time, if any), followed by cold air circulation.

4.Press to adjust temperature setting above room temperature. The cooling

system should stop operating, the fan should stop running (after the fan-off delay time, if any).

MULTI-STAGE/HEAT PUMP AUXILIARY OPERATION TEST

Follow these steps to energize all stages of hear or cool to permit system checks during installation.

HEAT: Press to raise temperature setting to 99°F, then hold for five seconds. The second and third stage (heat pump only) heat relays will energize immediately for test purposes. The LED indicator will glow green for first stage and yellow for second stage, and flashing yellow for third stage (heat pump only).

COOL: Press to lower temperature setting to 45°F, then hold for five seconds. The second stage cool relay will energize immediately for test purposes. The LED indicator will glow green for the first stage and yellow for second stage. EMERGENCY (heat pump only): Press SYSTEM to select EMER mode. The LED indicator will glow red for first stage (Aux) in emergency mode.

A flashing red LED indicates a malfunction in the system.

HUMIDIFIER SYSTEM (IF INSTALLED)

1.Press SYSTEM until HEAT is shown at the top of the display.

2.Press the HUMIDITY % button once and

release. Then press theto the maximum humidity setpoint and hold for 7

seconds until ON is displayed. It assures that the Humidifier will call for humidity when the thermostat calls for HEAT as outlined in the following steps.

3.Press PROGRAM RUN .

4.Press the HOLD button.

5.Press to raise the temperature setting 4°F above room temperature.

The 1st stage (LED Green) and then 2nd stage (LED Yellow) will be energized. The HM terminal will also energize for humidification. The lowercase letter h will appear to the right of HOLD, indicating that the thermostat is calling for Humidification.

6.Press PROGRAM RUN to end the HEAT/HUMIDIFIER test. NOTE: Be sure to press the Humidity button and reset the humidity to the level you desire.

DEHUMIDIFICATION SYSTEM (IF INSTALLED)

1.Press SYSTEM until COOL is shown at the top of the display.

2.Press the HUMIDITY % button once and

release. Then press to the minimum humidity setpoint and hold for 7 seconds

until ON is displayed. It assures that the Dehumidifier will call for dehumidifica- tion when the thermostat calls for COOL as outlined in the following steps.

3.Press PROGRAM RUN .

4.Press the HOLD button.

5.Press to lower the temperature setting 1°F below room temperature. The

1st stage of the cooling system should begin to operate and the LED indicator will glow Green. The lowercase letter d will appear to the right of HOLD, indicating that the thermostat is calling for Dehumidification.

6.Press the temperature to lower your setpoint 4°F below room temperature, the

DHM terminal will energize causing the FAN to go to high speed.

7.Press the HUMIDITY % button and set your desired dehumidification setpoint

in % RH using the and .

8.Press PROGRAM RUN to accept the change.

9

Image 9
Contents Precautions SpecificationsDescription Electrical DataConfiguring and PROGRAM- Ming InstallationRemove OLD Thermostat Attach Base to WallHeat Pump Terminal Outputs MULTI-STAGE Terminal OutputsReset Switch SwitchesE2/P Switch DHM Terminal Function Reset switch E2/P switchInstaller Configuration Time Installer TableBalance Point Temperature Compressor OFF DelayDisabling Automatic Changeover Mode Balance PointService Reminder Check Thermostat Operation Reset Button TroubleshootingResetting Thermostat Configuration and Programming TroubleshootingThermostat Setting and Thermostat Narrow or wide temperature swingNo Cool Heat, Cool or Fan Runs ConstantlySetpoint and room temperature Why does the system run withWhy is the temperature change What is the thermostat Click Test?

1F95CA-391 specifications

The White Rodgers 1F95CA-391 is a multifunctional smart thermostat designed to offer homeowners greater control over their heating and cooling systems. As part of the HVAC industry’s move toward smarter technology, this device blends user-friendly features with advanced automation to enhance energy efficiency and comfort.

One of the standout features of the White Rodgers 1F95CA-391 is its compatibility with multiple heating and cooling systems. It supports conventional, heat pump, and auxiliary heat setups, making it versatile for a wide range of homes and setups. This flexibility ensures that virtually any homeowner can easily integrate it into their existing HVAC system without extensive modifications.

The thermostat boasts a user-friendly touchscreen interface that simplifies programming and daily adjustments. The intuitive design allows users to set schedules based on their daily routines easily. This feature ensures that heating and cooling systems operate only when needed, thereby reducing energy consumption and lowering utility bills.

Another key characteristic of the White Rodgers 1F95CA-391 is its Wi-Fi connectivity. This technology enables homeowners to monitor and control their thermostats remotely via a smartphone or tablet. Users can adjust temperatures, view system status, and even receive alerts about potential issues, ensuring peace of mind and convenience.

Energy-saving technologies are also at the forefront of the White Rodgers 1F95CA-391’s design. It incorporates energy-saving algorithms that learn user preferences and adjust heating and cooling schedules accordingly. Additionally, features such as two-stage heating and cooling management enhance performance while helping to optimize energy consumption.

The White Rodgers 1F95CA-391 is equipped with advanced filtration reminders that alert users when it’s time to change the HVAC system’s filters. Regular filter changes not only prolong the life of the system but also improve indoor air quality.

Lastly, the device is designed with a sleek and modern aesthetic, making it a stylish addition to any home decor. The clear display is easy to read, and the overall design is compact, allowing it to blend seamlessly within any environment.

In summary, the White Rodgers 1F95CA-391 thermostat combines cutting-edge technology with ease of use. Its compatibility with various HVAC systems, remote access capabilities, and focus on energy efficiency make it a valuable investment for any homeowner looking to enhance comfort while optimizing energy use.