White Rodgers 1F95CA-391 specifications Installer Table, Time

Page 6

INSTALLER TABLE

NOTE: You must be in the User Configuration Menu to enter the Installer Table. Firmly press TIME FWD

and

TIME

BACK at same time and release to enter the Configuration Menu.

 

 

 

 

 

 

 

Step

Press Button(s)

Displayed (Factory Default)

Press UP or DOWN to select:

COMMENTS

See

Page

 

 

 

 

 

 

 

 

 

 

 

1

Firmly Press

MLTI STG

HEAT PUMP

Selects type of system. Selecting HEAT PUMP

5

 

SET TIME and

 

 

makes additional items for heat pump systems

 

 

SET DAY (hold

 

 

available.

 

 

for approx. 3 seconds)

 

 

 

 

 

 

 

 

 

 

2

TIME FWD

HEAT PUMP

2

1. One compressor on Y1.

5

 

(Heat Pump ONLY)

(1)

 

2. Two compressor on Y1, Y2.

 

 

 

 

 

 

 

3

TIME FWD

ELEC HEAT FAN

OFF

Fan cycles with call for heat if ON. Fan always

5

 

 

(ON)

 

cycles with pump stages.

 

4

TIME FWD

SET CYCL (05)

1 to 40 for multi-stage

Selects HEAT anticipation adjustment.

5

 

 

for MLTI_STG, (13) for

9 to 40 for heat pump

 

 

 

 

HEAT PUMP 1, (24)

 

 

 

 

 

for HEAT PUMP 2

 

 

 

5

TIME FWD

SET CYCL (24)

9 to 40

Selects COOL anticipation adjustment.

5

 

 

for MLTI_STG, (13) for

 

 

 

 

 

HEAT PUMP 1, (24)

 

 

 

 

 

for HEAT PUMP 2

 

 

 

 

 

 

 

 

 

6

TIME FWD

SET CYCL AUX

1 to 40

Selects AUXILIA RY stage anticipation adjustment.

5

 

(Heat Pump ONLY)

(08)

 

(Heat Pump ONLY)

 

 

 

 

 

 

 

7

TIME FWD

COOL FAN DELA OFF

0 to 127 seconds

Selects time delay for COOL fan OFF.

5

 

 

(00)

 

 

 

 

 

 

 

 

 

8

TIME FWD

FAN DELA ON

1 to 30 seconds

Selects time delay for fan ON. Applies only to

5

 

 

(01)

 

compressor stages for heat pump or COOL.

 

 

 

 

 

 

 

9

TIME FWD

HEAT FAN DELA OFF

0 to 127 seconds

Selects time delay for fan ON only when

5

 

 

(00)

 

ELECT HEAT FAN (Step 3) is ON.

 

 

 

 

 

 

 

10

TIME FWD

PUMP

OFF

Fossil Fuel Kit Alternative option. Turns compressor

5

 

(Heat Pump ONLY)

(ON)

 

OFF if Auxiliary is ON for longer than one minute.

 

 

 

 

 

(Heat Pump 1 & 2)

 

11

TIME FWD

COMP OFF DELA

(0) to (99)

Available if Pump (Step 10) is OFF. Selects the

7

 

(Heat Pump ONLY)

(60)

 

delay between de-energizing fossil fuel stage and

 

 

 

 

 

restarting Heat Pump stage.

 

12

TIME FWD

(Balance point temperature)

5 F to 50 F

Available if Pump (Step 10) is OFF and OUTDOOR

7

 

(Heat Pump ONLY)

bPT (35 F )

 

Sensor ON. Selects outdoor balance point

 

 

 

 

temperature for Heat Pump.

 

 

 

 

 

 

13

TIME FWD

(Balance point)

(01) to (09)

Available if Pump (Step 10) is OFF and OUTDOOR

7

 

(Heat Pump ONLY)

bP (05)

 

Sensor OFF. The higher the number the sooner the

 

 

 

 

 

auxilary stage energizes. The lower the number the

 

 

 

 

 

longer period of time before auxiliary is energized.

 

 

 

 

 

 

 

14

TIME FWD

(Programmable Blower

10 to 99%

Available if configured for HEAT PUMP. Adjustable

7

 

(Heat Pump ONLY)

Balance Point) bbP

 

from 99-10. Lowers the Blower speed if the Heat

 

 

 

(OFF)

 

Pump duty cycle is above the selected value in

 

 

 

 

 

percentage.

 

15

TIME FWD

COMP LOCK

ON

Selects compressor short-cycle protection.*

7

 

 

(OFF)

 

 

 

 

 

 

 

 

 

16

TIME FWD

CA

ON

Selects active Comfort Alert. Requires CA module

7

 

 

(OFF)

 

and CA interface module.

 

 

 

 

 

 

 

17

TIME FWD

HEAT-OFF COOL-AUTO

HEAT-OFF-COOL or

Allows selection of HEAT and COOL or HEAT,

7

 

 

or HEAT-EMER-OFF-

HEAT-EMER-OFF-

COOL and AU TO with SYSTEM button. (EMER

 

 

 

COOL-AUTO

COOL (for heat pumps)

appears in sequence after HEAT if HEAT PUMP

 

 

 

is selected).

 

 

 

(for heat pumps)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Program RUN

 

 

Returns to Normal Operation.

 

 

 

 

 

 

 

*Note: COMP LOCK OFF permanently defeats compressor lockout. You must turn this selection ON if you do not have a system that already provides compressor short-cycle protection. Please see “Lockout Bypass Option” to temporarily override compressor lockout.

6

Image 6
Contents Description SpecificationsPrecautions Electrical DataRemove OLD Thermostat InstallationConfiguring and PROGRAM- Ming Attach Base to WallMULTI-STAGE Terminal Outputs Heat Pump Terminal OutputsE2/P Switch DHM Terminal Function SwitchesReset Switch Reset switch E2/P switchInstaller Configuration Installer Table TimeDisabling Automatic Changeover Mode Compressor OFF DelayBalance Point Temperature Balance PointService Reminder Check Thermostat Operation Resetting Thermostat Configuration and Programming TroubleshootingReset Button TroubleshootingNo Cool Narrow or wide temperature swingThermostat Setting and Thermostat Heat, Cool or Fan Runs ConstantlyWhy is the temperature change Why does the system run withSetpoint and room temperature What is the thermostat Click Test?

1F95CA-391 specifications

The White Rodgers 1F95CA-391 is a multifunctional smart thermostat designed to offer homeowners greater control over their heating and cooling systems. As part of the HVAC industry’s move toward smarter technology, this device blends user-friendly features with advanced automation to enhance energy efficiency and comfort.

One of the standout features of the White Rodgers 1F95CA-391 is its compatibility with multiple heating and cooling systems. It supports conventional, heat pump, and auxiliary heat setups, making it versatile for a wide range of homes and setups. This flexibility ensures that virtually any homeowner can easily integrate it into their existing HVAC system without extensive modifications.

The thermostat boasts a user-friendly touchscreen interface that simplifies programming and daily adjustments. The intuitive design allows users to set schedules based on their daily routines easily. This feature ensures that heating and cooling systems operate only when needed, thereby reducing energy consumption and lowering utility bills.

Another key characteristic of the White Rodgers 1F95CA-391 is its Wi-Fi connectivity. This technology enables homeowners to monitor and control their thermostats remotely via a smartphone or tablet. Users can adjust temperatures, view system status, and even receive alerts about potential issues, ensuring peace of mind and convenience.

Energy-saving technologies are also at the forefront of the White Rodgers 1F95CA-391’s design. It incorporates energy-saving algorithms that learn user preferences and adjust heating and cooling schedules accordingly. Additionally, features such as two-stage heating and cooling management enhance performance while helping to optimize energy consumption.

The White Rodgers 1F95CA-391 is equipped with advanced filtration reminders that alert users when it’s time to change the HVAC system’s filters. Regular filter changes not only prolong the life of the system but also improve indoor air quality.

Lastly, the device is designed with a sleek and modern aesthetic, making it a stylish addition to any home decor. The clear display is easy to read, and the overall design is compact, allowing it to blend seamlessly within any environment.

In summary, the White Rodgers 1F95CA-391 thermostat combines cutting-edge technology with ease of use. Its compatibility with various HVAC systems, remote access capabilities, and focus on energy efficiency make it a valuable investment for any homeowner looking to enhance comfort while optimizing energy use.