Bosch Appliances DVA-12T Subsystem Connection and Operation, 1Cabling, Host Connection Topologies

Page 27

RAID Subsystem DVA-12T Installation ManualSubsystem Connection and Operation en 27

5

Subsystem Connection and Operation

5.1Cabling

i

Following are the requirements on the type of cables used to connect the subsystem’s iSCSI host ports:

Gigabit Ethernet network cables.

Cat6 type cables or better performance types.

Straight-through Ethernet cables with RJ-45 plugs.

Use of cross-over cables can also automatically be detected and re-routed for a valid con- nection.

Connection can be made directly to iSCSI initiators or through Gigabit Ethernet switches, to servers equipped with an iSCSI HBA, and then to client stations with a normal NIC or iSCSI HBA. The subsystem presents its logical capacity volumes through SCSI-like IDs and LUN’s, and these volumes appear as iSCSI targets through the network.

NOTICE!

All cables must be handled with care. Make sure Ethernet cables do not run parallel with power cords. To prevent interference within a rack system, the cable routing path must be carefully planned and they must not be bent.

5.2

Host Connection Topologies

The RAID subsystem provides two Gigabit Ethernet ports. The host-side connection can be made as the following:

Directly attached to the VIP X1600 encoder unit

Connection through Ethernet Switch

Network configurations, such as subnet or VLAN settings, can be applied as long as perma- nent IPs are available with the subsystem’s iSCSI host ports. Automatic assignment methods, such as DHCP, are not recommended for configuring the iSCSI connection. RAIDWatch need to access the array over standard TCP/IP and RAIDWatch may not recognize an array if port IPs have been changed.

Channel Default Settings

Model

Host Channels

Drive Channels

 

 

 

RAID subsystem

CH0 and CH1

Channels 2 to 13, each dedi-

 

 

cated to one connected drive

 

 

 

Table 5.1 Subsystem’s Default Channel Settings

 

Bosch Security Systems

F.01U.027.798 V1 2006.06

Image 27
Contents RAID Subsystem DVA-12T Page Table of Contents 01U.027.798 V1 Bosch Security Systems 3Certification Safety PrecautionsPrecautions and Instructions ESD Precautions01U.027.798 V1 Bosch Security Systems Introduction Product OverviewISCSI Host Ports Chassis Overview Enclosure Chassis2Front Panel Overview 3Hard Drive NumberingRear Panel Overview Subsystem Components Backplane BoardFront Handles RAID Controller Module Drive Trays4Controller Module Interfaces Dimm Module6BBU Cooling Modules Power Supply UnitsI2C bus LED Indicators4Audible Alarms Subsystem MonitoringNormalized Airflow Hot-swappable ComponentsHot-swap Capabilities ComponentsIntroduction Hardware InstallationInstallation Prerequisites Precautions and InstructionsStatic-free Installation General Installation ProcedureInstallation Procedure Done Rack/Cabinet Installation7Drive Tray Installation Installation Procedure FlowchartFront View of an Individual Drive Tray Drive Tray Key-lock Rotation Subsystem Monitoring Overview Subsystem MonitoringStatus-indicating LEDs Brief Overview of the LEDsDrive Tray LEDs 3Controller Module LEDs Ethernet Port LEDsName Color Status PSU LEDs BBU Module LEDAudible Alarm Default Threshold Values7Cooling Module LEDs Failed Devices 4I2C MonitoringHost Connection Topologies Channel Default Settings Model Host Channels Drive ChannelsSubsystem Connection and Operation 1CablingDirect-Attached, Single Connection 2Connection through an Ethernet Switches Check List Power OnPower On Procedure Power On Enclosure4Power On Status Check 4Power Off ProcedureOverview Subsystem Maintenance and UpgradingMaintenance General Notes on Component ReplacementController Module Maintenance Overview Replacing Controller Module ComponentsRemoving the Controller Module 3DIMM Module Replacement Replacing the Controller Module1DIMM Module Considerations Push Back the Module Clips on the Sides of the Dimm Module Dimm Module Replacement ProcedureReplacing a Faulty BBU Module BBU Warnings and Precautions2Procedure Replacing a Failed PSU Module PSU Module OverviewReplacing the PSU Module PSU Parts Identification Cooling Module Maintenance Cooling Module Overview2Replacing a Cooling Module 7Replacing a Failed Hard Drive Hard Drive Maintenance Overview11 Front View of an Individual Drive Tray Replacing a Hard DriveInstall the new hard drive Technical Specifications SpecificationsSpecification Controller Specifications6RAID Management Drive Tray SpecificationsPower Supply Specifications Cooling Module SpecificationsNPC Fault Tolerance ManagementModel Name Description Spare Parts and AccessoriesAccessories Spare PartsCN1 Pin Number Pin Name Pin OutsCOM1 Cable DB9 and Audio Jack Pin Outs Ethernet Port Pin OutsPin Pin Name Main PowerPage Numerics IndexLAN XOR Page Page Bosch Security Systems

DVA-12T specifications

The Bosch Appliances DVA-12T is a standout in the field of kitchen ventilation, offering a seamless blend of high performance, modern design, and innovative technology. This under-cabinet range hood is engineered to deliver top-notch airflow while maintaining a surprisingly quiet operation, making it an ideal choice for both professional and home chefs.

One of the primary features of the DVA-12T is its powerful ventilation system, which boasts an impressive airflow capacity of 400 CFM. This ensures that even the most intense cooking sessions are met with adequate ventilation, effectively removing smoke, odors, and grease from the kitchen environment. The appliance is equipped with a three-speed fan that allows users to choose the appropriate level of airflow based on cooking needs, from simmering to high-heat sautéing.

In terms of design, the Bosch DVA-12T exemplifies contemporary aesthetics with its sleek stainless steel finish, which not only enhances the kitchen's appearance but is also easy to clean. Its low-profile design allows it to fit neatly under cabinets, making it a space-saving solution that does not compromise on power or effectiveness.

The DVA-12T is fitted with an advanced lighting system that includes LED lights, providing bright and efficient illumination over the cooking area. These lights enhance visibility while cooking and contribute to energy savings compared to traditional incandescent lights.

Moreover, the DVA-12T features a dishwasher-safe baffle filter that efficiently captures grease and enhances the longevity of the appliance. This user-friendly feature simplifies maintenance, allowing consumers to keep their range hood functioning optimally without hassle.

One notable characteristic of the Bosch DVA-12T is its quiet operation. With noise levels that remain as low as 46 decibels, this range hood ensures that you can enjoy conversations and the ambiance of your kitchen while cooking. This is achieved through advanced engineering that minimizes turbulence and promotes smooth airflow.

In conclusion, the Bosch Appliances DVA-12T stands out for its powerful ventilation, stylish design, user-friendly features, and quiet operation. It's an ideal choice for anyone looking to enhance their culinary environment while maintaining a serene atmosphere in the kitchen. Whether for everyday cooking or gourmet meals, this range hood represents the essence of Bosch's commitment to quality and innovation.