Bosch Appliances DVA-12T installation manual Subsystem Monitoring Overview

Page 21

RAID Subsystem DVA-12T Installation ManualSubsystem Monitoring en 21

4

Subsystem Monitoring

4.1

Subsystem Monitoring Overview

The RAID subsystem is equipped with a variety of self-monitoring features that help to keep subsystem managers informed of the subsystem operational status. These monitoring fea- tures provide vital feedback to help you maintain the operational integrity of the subsystem. Prompt response to warnings and subsystem component failure notifications will improve the overall operation of the subsystem and help ensure the longevity of the RAID subsystem. Self-monitoring features include:

Firmware (FW): The controller in the RAID subsystem comes with preinstalled firmware, which can be accessed using a PC hyper-terminal connected through the RAID sub- system’s COM port. Device status information can be obtained from the FW configuration utility.

RAIDWatch: RAIDWatch is a fully integrated, Java-based,

Graphical User Interface (GUI) that came with the subsystem and can be used to monitor and maintain the subsystem using your web browsers. Connection to RAIDWatch is made using the existing Ethernet ports.

The RAIDWatch Panel View can be customized to show a direct, graphical representation of the RAID subsystem in the content panel of the RAIDWatch screen. Panel View allows you to quickly determine the operational status of critical components.

Bosch RAIDWatch Server: The Bosch RAIDWatch Server is a powerful module that runs as an independent program from RAIDWatch and can be installed redundantly on different hosts. It is used for event notification via email, fax, LAN broadcast, SNMP traps, MSN Messenger, ICQ, SMS (Short Message Service), and the configuration utility screen. The Configuration Client helps prevent blind time and keeps you constantly informed as to the status of the storage management subsystem. Instructions on how to activate the Configuration Client functionality are given in the RAIDWatch User’s Manual.

LEDs: Device-status-indicating LEDs are located on all active components. These LEDs inform you of the integrity of a given component or a given link. You should become famil- iar with the different LEDs that are present on the subsystem and be aware of their func- tions. (See Section 4.2 Status-indicating LEDs)

Audible alarm: An audible alarm is present on the subsystem

controller board and will be triggered if any of a number of threatening events occurred. These events usually jeopardize the functional and operational integrity of the controller board and must be heeded at all times. Events such as a breaching of the temperature threshold will trigger the alarm. If a subsystem manager is present, the manager should use the PC hyper-terminal to determine the cause of the alarm and take the appropriate corrective measures. (See Section 4.3 Audible Alarm)

Inter-Integrated Circuit (I2C): The I2C bus monitors the

operational integrity of the cooling modules, RAID controller board temperature and volt- age readings.

Subsystem monitoring is a necessary part of subsystem management. If failure events or other disruptive events are detected and reported, the subsystem managers must take the appropri- ate action to rectify the problem. Failure to act in a properly specified manner to a system event (like overheating) can cause severe and permanent damage to the subsystem.

Bosch Security Systems

F.01U.027.798 V1 2006.06

Image 21
Contents RAID Subsystem DVA-12T Page Table of Contents 01U.027.798 V1 Bosch Security Systems Precautions and Instructions Safety PrecautionsESD Precautions 3Certification01U.027.798 V1 Bosch Security Systems Introduction Product OverviewISCSI Host Ports Chassis Overview Enclosure Chassis2Front Panel Overview 3Hard Drive NumberingRear Panel Overview Subsystem Components Backplane BoardFront Handles RAID Controller Module Drive Trays4Controller Module Interfaces Dimm Module6BBU Cooling Modules Power Supply Units4Audible Alarms LED IndicatorsSubsystem Monitoring I2C busHot-swap Capabilities Hot-swappable ComponentsComponents Normalized AirflowInstallation Prerequisites Hardware InstallationPrecautions and Instructions IntroductionStatic-free Installation General Installation Procedure7Drive Tray Installation Rack/Cabinet InstallationInstallation Procedure Flowchart Installation Procedure DoneFront View of an Individual Drive Tray Drive Tray Key-lock Rotation Subsystem Monitoring Overview Subsystem MonitoringStatus-indicating LEDs Brief Overview of the LEDsDrive Tray LEDs 3Controller Module LEDs Ethernet Port LEDsName Color Status PSU LEDs BBU Module LEDAudible Alarm Default Threshold Values7Cooling Module LEDs Failed Devices 4I2C MonitoringSubsystem Connection and Operation Channel Default Settings Model Host Channels Drive Channels1Cabling Host Connection TopologiesDirect-Attached, Single Connection 2Connection through an Ethernet Switches Power On Procedure Power OnPower On Enclosure Check List4Power On Status Check 4Power Off ProcedureMaintenance Subsystem Maintenance and UpgradingGeneral Notes on Component Replacement OverviewController Module Maintenance Overview Replacing Controller Module ComponentsRemoving the Controller Module 3DIMM Module Replacement Replacing the Controller Module1DIMM Module Considerations Push Back the Module Clips on the Sides of the Dimm Module Dimm Module Replacement ProcedureReplacing a Faulty BBU Module BBU Warnings and Precautions2Procedure Replacing a Failed PSU Module PSU Module OverviewReplacing the PSU Module PSU Parts Identification Cooling Module Maintenance Cooling Module Overview2Replacing a Cooling Module 7Replacing a Failed Hard Drive Hard Drive Maintenance Overview11 Front View of an Individual Drive Tray Replacing a Hard DriveInstall the new hard drive Technical Specifications SpecificationsSpecification Controller SpecificationsPower Supply Specifications Drive Tray SpecificationsCooling Module Specifications 6RAID ManagementNPC Fault Tolerance ManagementAccessories Spare Parts and AccessoriesSpare Parts Model Name DescriptionCOM1 Cable DB9 and Audio Jack Pin Outs Pin OutsEthernet Port Pin Outs CN1 Pin Number Pin NamePin Pin Name Main PowerPage Numerics IndexLAN XOR Page Page Bosch Security Systems

DVA-12T specifications

The Bosch Appliances DVA-12T is a standout in the field of kitchen ventilation, offering a seamless blend of high performance, modern design, and innovative technology. This under-cabinet range hood is engineered to deliver top-notch airflow while maintaining a surprisingly quiet operation, making it an ideal choice for both professional and home chefs.

One of the primary features of the DVA-12T is its powerful ventilation system, which boasts an impressive airflow capacity of 400 CFM. This ensures that even the most intense cooking sessions are met with adequate ventilation, effectively removing smoke, odors, and grease from the kitchen environment. The appliance is equipped with a three-speed fan that allows users to choose the appropriate level of airflow based on cooking needs, from simmering to high-heat sautéing.

In terms of design, the Bosch DVA-12T exemplifies contemporary aesthetics with its sleek stainless steel finish, which not only enhances the kitchen's appearance but is also easy to clean. Its low-profile design allows it to fit neatly under cabinets, making it a space-saving solution that does not compromise on power or effectiveness.

The DVA-12T is fitted with an advanced lighting system that includes LED lights, providing bright and efficient illumination over the cooking area. These lights enhance visibility while cooking and contribute to energy savings compared to traditional incandescent lights.

Moreover, the DVA-12T features a dishwasher-safe baffle filter that efficiently captures grease and enhances the longevity of the appliance. This user-friendly feature simplifies maintenance, allowing consumers to keep their range hood functioning optimally without hassle.

One notable characteristic of the Bosch DVA-12T is its quiet operation. With noise levels that remain as low as 46 decibels, this range hood ensures that you can enjoy conversations and the ambiance of your kitchen while cooking. This is achieved through advanced engineering that minimizes turbulence and promotes smooth airflow.

In conclusion, the Bosch Appliances DVA-12T stands out for its powerful ventilation, stylish design, user-friendly features, and quiet operation. It's an ideal choice for anyone looking to enhance their culinary environment while maintaining a serene atmosphere in the kitchen. Whether for everyday cooking or gourmet meals, this range hood represents the essence of Bosch's commitment to quality and innovation.