Guideline

Guideline

 

 

 

Installation of the acoustic interface (driver unit)

English

[1]Double-sided tape

[2]Chassis

[3]Set screws

[4]Cable hole

[5]Ceiling sash, etc.

1. The driver unit is connected to the top of the upper acoustic tube. Use the screws provided and double-sided tape to secure the chassis to the position where the glass meets the ceiling.

2. Align the position with the guideline, and make a pilot hole in the ceiling. When deciding the position, it is necessary to take into account the extra thickness caused by the double-sided tape.

3. When the position is determined, attach double-sided tape to the glass (first attach double-sided tape to the bottom outer surface of the chassis), and then secure to the ceiling with the screws provided.

Make the cable hole in the ceiling for the speaker cable and microphone cable at the same time as making the screw holes.

4-7

 

 

 

 

1

 

 

 

 

 

 

 

 

[1]

 

 

[2]

 

 

 

 

[3]

 

 

2

 

 

[6]

 

 

 

 

 

 

 

 

[7]

 

[4]

 

[5]

 

[8]

 

 

 

3

Guideline

[9]

[9]

[12]

 

 

[13]

 

 

[14]

 

 

 

 

 

 

 

 

10 mm

[10]

 

 

 

 

 

 

[11]

 

 

Installation of the acoustic interface (lower acoustic tube) English

Generally, it is likely that only one acoustic tube (1 m) will be used for the lower acoustic tube.When using 2 or 3 tubes, refer to the items in "4-9 Installation of the acoustic interface (upper acoustic tube)" before installation.

[1]Used side (red label side)

[2]Discarded side (blue label side)

[3]Blue label

[4]Main unit

[5]Base

[6]Tube connector

[7]Red label

[8]Double-sided tape

[9]Fixing base of the lower acoustic tube

[10]Tube fixer

[11]Counter sash,etc.

[12]Acoustic tube main unit

[13]Connection groove

[14]Connection ridge

Temporarily insert the red label side of the acoustic tube into the connector on the bottom of the acoustic I/O tube, and align with the installation surface. Keeping the acoustic I/O tube at the height that was decided earlier, decide where the acoustic tube should be cut on the bottom. The ideal cutting position would be at a length where the bottom of the acoustic tube makes contact with the bottom of the tube fixer when the tube is inserted into the fixer.

Remove the tube connector that is installed on to the acoustic tube. Move the packing installed on the tube connector to the bottom of the acoustic I/O tube (microphone cord side).

When using only one acoustic tube on the lower side (1 m or less), the removed tube connector is not used. When using 2 or more tubes, the tube connector is used together with the packing in the connection.

Cut the acoustic tube at the appropriate length. When cutting the lower acoustic tube, make sure that the side that is discarded is the blue label side. Do not cut the red label side because it is the tube connection side.

Cut while the acoustic tube main unit and fixing base are correctly assembled together. This is easier if tape is used to secure both sides so they are not misaligned.

Cut carefully so that the cut surface is perpendicular to the long side of the tube.

After cutting,use a file or sandpaper to smooth the cut surface of the acoustic tube main unit and fixing base so they can both be inserted

into the tube fixer.

1. There are screws for setting the fixing base and acoustic tube main unit at 5 cm, 35 cm, 65 cm and 95 cm from the blue label. Make sure the cutting position is not the same as these fixing positions.

2. When cutting one acoustic tube and using it above and below the acoustic I/O tube, use the blue label side of the acoustic tube as the lower acoustic tube. Use the red label side of the acoustic tube as the upper acoustic tube. The tube connector is not used, but packing is used at the connection of the upper acoustic tube and acoustic I/O tube.

2. Attachment

Pull out the acoustic tube main unit and fixing base,and attach double-sided tape to the outer surface (flat surface)of the fixing base.

After attaching the double-sided tape to the fixing base, position the tube so that the red label is on the upper side,and insert the bottom

into the tube fixer.Align with the guideline while the tube makes contact with the bottom of the tube fixer, and attach to the glass.

3. The double-sided tape can be seen from the operator side, so when attaching make sure it does not protrude from the edges and is not bent.

4. The acoustic tube main unit can be pulled out by sliding it up 10mm from the fixing base.

3.Check

After attachment,insert by aligning the connection ridge of the acoustic tube main unit (with the red label on the upper side)and the connection groove of the fixing base. Try to secure while pushing downwards (the slide distance is approximately 10mm). Check that the tube can be inserted to the bottom of the tube fixer and that it can

be fully secured.After checking,remove the acoustic tube main unit. Do not apply excessive force,as the adhesive power of the double-

sided tape will not yet have reached its full strength.

- 9 -

Image 9
Contents Security Window Intercom System Package Contents Description Operator units English InstallationOuter microphone/speakerEnglish Acoustic interface EnglishMain materials and tools English MountingOperation unitEnglish Main unitEnglishInstallation of the acoustic interface tube fixer English English 10mm Acoustic interface wiring English Fixing of acoustic interface English Options English Outer microphone/speaker EnglishSpeaker Wiring DiagramWiring English Wiring distanceCable layout English Names English NamesSetting upEnglish Setting UPOperation English OperationsSpecifications Warranty

IME-150, ISE-100, IAX-100, IME-100, IMU-100 specifications

Aiphone, a leading manufacturer of intercom and security communication systems, has developed a range of products designed for different needs and environments. Among their notable offerings are the IAI-100, IME-100, IMU-100, IAX-100, and ISE-100 models. Each device comes with unique features, advanced technologies, and specific characteristics suited for various applications.

The Aiphone IAI-100 serves as a powerful intercom system that is ideal for businesses and residential settings. It features a high-resolution display that allows for clear video communication. The IAI-100 utilizes advanced networking technologies, such as IP connectivity, enabling seamless integration into existing networks. With its user-friendly interface, users can easily navigate through functions, making communication efficient. Additionally, its robust security features ensure that conversations are private and protected from unauthorized access.

The IME-100 model is designed for enhanced communication in environments requiring reliability and durability. It incorporates a weather-resistant design, making it suitable for outdoor installations. The IME-100 also supports two-way audio and video communication, providing users with a comprehensive solution for monitoring entry points. Its advanced motion detection technology alerts users to any movement, ensuring proactive security measures.

The IMU-100 offers a versatile solution for both audio and video intercom needs. This unit stands out with its ability to connect multiple devices, allowing for the management of several communication channels simultaneously. Its integration with mobile applications enables users to access their intercom system remotely, offering convenience and control. The IMU-100 also supports high-definition video, ensuring clear visuals for identification and communication purposes.

The IAX-100 model is focused on integrating access control with intercom functionalities. This unit allows users to grant or deny access to visitors through a single interface. It features a built-in access control panel and is compatible with various locking mechanisms, making it a comprehensive solution for commercial buildings. The IAX-100 also provides detailed logging of entry attempts, enhancing security oversight.

Lastly, the ISE-100 is designed specifically for education and institutional applications. It features an easy-to-use interface tailored to the needs of school environments, supporting quick communication between teachers, staff, and administration. The ISE-100 also has features such as emergency notification systems and integration with classroom technology, ensuring safety and communication efficiency.

In summary, Aiphone's IAI-100, IME-100, IMU-100, IAX-100, and ISE-100 models are expertly crafted to meet varying communication and security needs across different settings. Each device emphasizes innovative technologies, user-friendly interfaces, and robust security features, making them valuable tools for enhancing connectivity and safety.