Aiphone IME-100, Iai-100, IME-150, ISE-100, IMU-100, IAX-100 Main unitEnglish, Operation unitEnglish

Page 7

Main unitEnglish

Install the main unit under the counter or desk on the operator side. The cables from the other units will be connected at a later stage by temporarily removing the main unit.

[1]Mounting bracket

[2]Counter/desk

[3]Switch

[4]Front panel

[5]Main unit

[6]Terminal block

[7]Transmit output speaker cable

[8]Receive microphone input cable

[9]Power supply adapter

1.Install the mounting bracket with the 4 screws provided, in the position where the main unit will be installed.

Install in a safe position so that the knobs do not project out from under the counter.

2.Position the main unit on the mounting bracket (temporarily tighten with the 4 screws provided), and check whether the knobs or any other part projects out.

3.Connect the receive input microphone cable that comes from

the acoustic I/O tube (or optional microphone), and the transmit output speaker cable that comes from the driver unit (or outer speaker) to the main unit terminal block.

Connect the receive input microphone cable that comes from the acoustic I/O tube (or optional microphone) to R MIC [+ – E] of the main unit terminal block. Insert the hot (red) wire of the receive microphone into the + terminal, the ground (white) wire into the – terminal, and the shield wire into the E terminal.

Connect the transmit output speaker cable that comes from the driver unit (or outer speaker) to T OUT [H C] of the main unit terminal block. Insert the hot (black) wire of the transmit speaker into the + terminal, the ground (white) wire into the – terminal.

1. Be sure not to short the power supply cable and speaker cable, as it could cause a speaker malfunction.

2. Cut the cable in advance so that it is long enough to reach the installation position of the main unit.

4.Position the power supply adapter under the counter or desk, in a safe location between the power supply socket and main unit. Connect the + terminal of the power supply adapter to the DC24V + terminal of the main unit, and the – terminal of the power supply adapter to the DC24V – terminal of main unit.

3. On power supply, take FG () terminal to an earth ground.

4. Do not turn on the power supply adapter until all of the installation work has been completed.

5. Do not install in a location exposed to heat or water, and also avoid locations where excessive amounts of dust accumulate.

4-3

 

1

[1]

 

[2]

[3]

 

2

 

MU-100

OU-100

[4]

[4]

 

 

[5]

Operation unitEnglish

Position the operation unit on the counter or desk on the operator side. Select a location where operation will be easy, and check that the operation cable provided reaches the main unit.

[1]Gooseneck microphone

[2]Microphone jack

[3]Screw w/washer

[4]Connector

[5]Connection cord

1.When using the gooseneck microphone for transmission, install the gooseneck microphone before making the connections. Install by removing the 2 screws on the rear of the operation unit and removing the rear cover.

A headset can also be used. Use a type of headset suitable for your needs.

Ø3.5 plug Impedance: 32

Rated input: 40 mW or more

Maximum input: 100 mW or more

Only mono type headsets can be used. 2. Connect to the main unit.

1. If you are going to make a hole in the desk for the connection cable, make sure that it is big enough for the connector at the end of the cable to pass through.

2. If a raceway is used on the desk to manage the wiring, be sure to select a route that does not interfere with operation.

3. When inserting or removing the connector,hold the connector housing and align the polarity. If excessive force is applied to the wires, they could break or pull out of the connector, so be especially careful during this operation.

- 7 -

Image 7
Contents Security Window Intercom System Package Contents Description Operator units English InstallationOuter microphone/speakerEnglish Acoustic interface EnglishMain materials and tools English MountingOperation unitEnglish Main unitEnglishInstallation of the acoustic interface tube fixer English English 10mm Acoustic interface wiring English Fixing of acoustic interface English Options English Outer microphone/speaker EnglishSpeaker Wiring DiagramWiring distance Wiring EnglishCable layout English Names English NamesSetting upEnglish Setting UPOperation English OperationsSpecifications Warranty

IME-150, ISE-100, IAX-100, IME-100, IMU-100 specifications

Aiphone, a leading manufacturer of intercom and security communication systems, has developed a range of products designed for different needs and environments. Among their notable offerings are the IAI-100, IME-100, IMU-100, IAX-100, and ISE-100 models. Each device comes with unique features, advanced technologies, and specific characteristics suited for various applications.

The Aiphone IAI-100 serves as a powerful intercom system that is ideal for businesses and residential settings. It features a high-resolution display that allows for clear video communication. The IAI-100 utilizes advanced networking technologies, such as IP connectivity, enabling seamless integration into existing networks. With its user-friendly interface, users can easily navigate through functions, making communication efficient. Additionally, its robust security features ensure that conversations are private and protected from unauthorized access.

The IME-100 model is designed for enhanced communication in environments requiring reliability and durability. It incorporates a weather-resistant design, making it suitable for outdoor installations. The IME-100 also supports two-way audio and video communication, providing users with a comprehensive solution for monitoring entry points. Its advanced motion detection technology alerts users to any movement, ensuring proactive security measures.

The IMU-100 offers a versatile solution for both audio and video intercom needs. This unit stands out with its ability to connect multiple devices, allowing for the management of several communication channels simultaneously. Its integration with mobile applications enables users to access their intercom system remotely, offering convenience and control. The IMU-100 also supports high-definition video, ensuring clear visuals for identification and communication purposes.

The IAX-100 model is focused on integrating access control with intercom functionalities. This unit allows users to grant or deny access to visitors through a single interface. It features a built-in access control panel and is compatible with various locking mechanisms, making it a comprehensive solution for commercial buildings. The IAX-100 also provides detailed logging of entry attempts, enhancing security oversight.

Lastly, the ISE-100 is designed specifically for education and institutional applications. It features an easy-to-use interface tailored to the needs of school environments, supporting quick communication between teachers, staff, and administration. The ISE-100 also has features such as emergency notification systems and integration with classroom technology, ensuring safety and communication efficiency.

In summary, Aiphone's IAI-100, IME-100, IMU-100, IAX-100, and ISE-100 models are expertly crafted to meet varying communication and security needs across different settings. Each device emphasizes innovative technologies, user-friendly interfaces, and robust security features, making them valuable tools for enhancing connectivity and safety.