INSTALLATION

A-5

 

 

 

Cooler and insert the nipple into the connector nut so that the threaded end of the connector nut points away from the barbed end of the nipple. Twist the barbed end of the nipple into the hose until the shoulder of the nipple is flush with the end of the hose. Secure the hose onto the nipple with a hose clamp to insure that the connection is water tight. No water can leak from the connection if it is properly attached. Repeat the procedure for the OUTLET hose. When complete, reference Figure 2 and fol- low the connection procedure detailed below for connector nuts that mate to the Magnum Cooler connector block.

For additional water lines that do not mate with Magnum Cooler connections, order:

Order:

(2)

T15007-2 Connector Nuts*

 

(2)

T15008 Nipples*

 

(2)

S10888-35 Hose Clamps*

For all Lincoln products and those with a connector nut on the water hose which mates with the connector block at the back of a Magnum Cooler:

Save the two connector nuts and nipples provided with the unit for future use. (Reference Figure 2). Take the water INLET hose (colored or tagged blue on most hoses) and thread it into the coolant OUT line located on the right hand side of the connector block at the back of the Cooler. Secure the connector nut of the hose tightly into the connector block with a wrench so that leak- ing does not occur. Then take the OUTLET hose (colored or tagged red on most hoses) and thread it into the coolant IN line located on the left hand side of the connector block. Again, tight- ly secure the connector nut of the hose into the connector block of the Cooler with a wrench to insure that no leaking occurs. BE CERTAIN THAT NO LEAKS EXIST WHEN COOLER IS TURNED ON. A LEAK WILL DEPLETE RESERVOIR VOLUME, CAUSE POOR OR COOLING PERFORMANCE AND REDUCE GUN OR TORCH LIFE.

NOTE: Be certain that only 5/8-18 left hand male nuts with clean and smooth threads are used on your water hoses. Poor connections cause water to leak at connector block, down hose lines, and eventually out the case sides of the unit.

*The connector and nipples listed fit tightly onto 4mm (5/32”) to 4.8mm (3/16”) inner diameter hose, but if clamped tightly to the hose, can fit up to 6.4mm (1/4” inner diameter hose.

HORIZONTALLY MOUNTING MAGNUM COOLERS ON LINCOLN TIG POWER SOURCES

Magnum Coolers can be mounted either upright or horizontally. For a complete compact system, Magnum 10-I or 20-I Cooler can be mounted horizon- tally on the roof of Lincoln TIG Power Sources using the optional K559-2 Horizontal TIG Mounting Bracket. For proper installation, follow the instructions provided with the kit. (See Figures 3a and 3b)

VERTICALLY MOUNTING MAGNUM COOLERS TO LINCOLN UNDERCARRIAGES K874, K840-1*, K841- 1*, or K842-1*

When placing the Cooler 10-I or 20-I at the back of a Lincoln Undercarriage used in tandem with a Lincoln MIG power source, order K559-3 Magnum Cooler MIG Mounting Bracket.

Reference Figure 3c and Table 2 for proper connec- tion of the bracket to the back bolt pattern of the Cooler. With the four Phillips head screws supplied, align the bracket onto the back of the Cooler at the proper holes displayed in Figure 3c. Do not fully tight- en the bracket allowing the bracket to slightly move up and down. Place the Cooler at the back right of the undercarriage so that the lip of the Cooler bracket rests on the top of the undercarriage upper cylinder support. Align the holes of the Cooler bracket with the holes on the undercarriage upper cylinder support. Fasten the Cooler bracket with the holes on the undercarriage upper cylinder support. Fasten the Cooler bracket onto the undercarriage support with both 1/4-20 bolts, 1/4-20 hex nuts, plain washers and lock washers provided. Be certain to tighten all the fasteners when the installation is complete.

* Not available at time of printing.

FIGURE 2

Inlet and Outlet Hose Connection Diagram

COOLANT

COOLANT

IN

OUT

FROM TO

HEAT HEAT

SOURCE SOURCE

(RED) (BLUE)

MAGNUM COOLER 10-I & 20-I

Image 12
Contents Magnumcoolers 10-I and 20-I March Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcExplanation of Symbols That Appear on this Equipment OFFTable of Contents Installation MIGTIG Product Description Installation Product OverviewFilling the Reservoir Water Line ConnectionProper Coolant Addition T15008 Nipples Scheme Cooler 10-I Mounting Scheme Water Cooled Equipment Installation Coolant OUT GUN Cable Coolant OUT K529-10 Power Input Cable with Water GAS Lines K529-10 Power Input Cable ConnectionSafety Precautions Operating PrecautionsLighted Power Switch OperationMagnum System Monitor Demand System with Water Valve or SOLE- NoidSurge Protection FAN Motor and FAN BladePump Failure Cooling EfficiencyResult the GUN or Torch Feels COOL- ER Result the GUN or Torch Feels HOT- TERCirculation of Magnum Cooler PACAccessories Parts Description for Magnum Cooler AccessoriesMaintenance Heat Exchanger MaintenanceReservoir Maintenance Troubleshooting Troubleshooting GuideDo not Leave Power Troubleshooting Troubleshooting Diagrams Magnum Coolers Codes 9743 Thru Precaucion Warnung