TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
|
|
|
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
Pump operates, but fan does not. | a. Internal AC circuit open. | a. Secure AC connectors on rec- |
|
| tifier bridge. |
| b. Fan blade contacting heat | b. If fan blades are plastic, |
| exchanger. | replace. Reset fan clearance |
|
| and secure fan to motor shaft. |
| c. Fan motor failure | c. Replace fan motor with Fan |
|
| Motor and Mount Assembly. |
Cooler trips outlet circuit breaker. | a. Circuit overloaded. | a. Check outlet circuit breaker. |
| b. Cooler electrical component | b. Replace suppressor assembly |
| failure. | and rectifier bridge inside of |
|
| Cooler. |
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
MAGNUM COOLER